Influence of the clearance on in-vitro tribology of large diameter metal-on-metal articulations pertaining to resurfacing hip implants

被引:95
作者
Rieker, CB
Schön, R
Konrad, R
Liebentritt, G
Gnepf, P
Shen, M
Roberts, P
Grigoris, P
机构
[1] Zimmer Europe GmbH, CH-8404 Winterthur, Switzerland
[2] Royal Gwent Hosp, Dept Orthopaed & Trauma, Newport NP9 2UB, Gwent, Wales
[3] Univ Athens, Dept Orthopaed 2, Athens, Greece
[4] Univ Bradford, Sch Engn, Dept Med Engn, Bradford BD7 1DP, W Yorkshire, England
关键词
D O I
10.1016/j.ocl.2005.02.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Large diameter metal-on-metal articulations may provide an opportunity for wear reduction in total hip implants because earlier studies have shown that the formation of a fluid film that completely separates the bearing surfaces is theoretically possible. In such a lubrication mode and under ideal conditions, there is theoretically no amount of wear. Studies have suggested that the two primary parameters controlling the lubrication mode are the diameter and the clearance of the articulation. The goal of the present study was to experimentally investigate the influence of these two parameters on the wear behavior of large diameter metal-on-metal articulations pertaining to resurfacing hip implants. The results of this in vitro investigation showed that longer running-in periods and higher amounts of running-in wear were associated with larger clearances.
引用
收藏
页码:135 / +
页数:9
相关论文
共 24 条
[1]  
Amstutz H C, 1998, J Orthop Sci, V3, P169, DOI 10.1007/s007760050038
[2]   Serum cobalt levels after metal-on-metal total hip arthroplasty [J].
Brodner, W ;
Bitzan, P ;
Meisinger, V ;
Kaider, A ;
Gottsauner-Wolf, F ;
Kotz, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2168-2173
[3]  
Cham FW, 1998, AM SOC TEST MATER, V1346, P111
[4]  
CHAN FW, 1999, CLIN ORTHOP RELAT R, V369, P11
[5]  
DELAUNAY C, 2001, WORLD TRIBOLOGY FORU, P189
[6]  
DOERIG MF, 2001, WORLD TRIBOLOGY FORU, P197
[7]   A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements [J].
Goldsmith, AAJ ;
Dowson, D ;
Isaac, GH ;
Lancaster, JG .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) :39-47
[8]  
Hallab N. J., 2006, CLIN ORTHOP RELAT R, V88, P1171
[9]  
Harris WH, 2001, CLIN ORTHOP RELAT R, P66
[10]  
MACDONALD SJ, 2004, CLIN ORTHOP RELAT R, V429, P86