The transcatheter management of the neonate and infant with pulmonary atresia and intact ventricular septum

被引:4
作者
Cheatham, JP [1 ]
机构
[1] Univ Nebraska, Med Ctr, Omaha, NE 68114 USA
关键词
D O I
10.1111/j.1540-8183.1998.tb00139.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The optimal management of the neonate and infant with pulmonary atresia (PA) and intact ventricular septum (IVS) remains controversial. The ultimate aim of any treatment algorithm is to achieve a Sour-chambered, biventricular, completely separated circulation In 1991, transcatheter perforation of the atretic membrane followed by successful balloon valvuloplasty was reported using a laser-assisted guidewire in the United Kingdom and the stiff end of a guidewire in the United States. The following year, a radiofrequency (RF) guide-wire was successfully used while stenting of the ductus arteriosus to maintain adequate pulmonary blood was also reported Most recently, a steerable 5 Fr RF catheter was used to "burn" the atretic membrane. From a series of 15 publications, a total of 69 neonates underwent attempted pulmonary valve perforation: 17 laser guidewire, 28 RF guidewire, 25 stiff end guidewire, and I steerable RF catheter. Successful perforation by technique was: 82.4% laser; 88.5% RF, 68% stiff end and 100% steerable RF. The accumulative success rate was 79.7%, mortality 4.3%, major complication 18%, and need for additional pulmonary blood 48%. Follow-up thus far has been encouraging. The technique of transcatheter perforation of the atretic pulmonary valve membrane is demanding and nor without risk, but in experienced hands can be successful nearly 90% of the time using the RF guidewire. RF energy is commonly used for other cardiac problems and has inherent cost and availability advantages over laser energy. Since nearly 50% of the neonates still require additional pulmonary bloodflow the interventionalist must be capable and ready to stent the PDA, or send to surgery. The neonate with right ventricular (RV) dominant coronary circulation remains a high risk group. However, careful cardiac catheterization with temporary transcatheter RV decompression may lead to a better understanding of this complex physiology.
引用
收藏
页码:363 / 387
页数:25
相关论文
共 147 条
[1]   Balloon dilatation of the pulmonary valve in a patient with pulmonary atresia and intact ventricular septum using a commercially available radiofrequency catheter [J].
Akagi, T ;
Hashino, K ;
Maeno, Y ;
Ishii, M ;
Sugimura, T ;
Kawano, T ;
Kato, H .
PEDIATRIC CARDIOLOGY, 1997, 18 (01) :61-63
[2]  
AKIBA T, 1994, J THORAC CARDIOV SUR, V108, P1
[3]  
Anderson R, 1987, PAEDIAT CARDIOLOGY, P711
[4]  
Anderson RH., 1991, CARDIOL YOUNG, V1, P105, DOI [DOI 10.1017/S1047951100000214, 10.1017/S1047951100000214]
[5]   TWO-DIMENSIONAL ECHOCARDIOGRAPHIC EVALUATION OF TRICUSPID HYPOPLASIA IN PULMONARY ATRESIA [J].
ANDRADE, JL ;
SERINO, W ;
DELEVAL, M ;
SOMERVILLE, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (02) :387-388
[6]   ANOMALOUS CORONARY ARTERY CONNECTING WITH RIGHT VENTRICLE ASSOCIATED WITH PULMONARY STENOSIS AND ATRIAL SEPTAL DEFECT [J].
ANSELMI, G ;
BLANCO, P ;
CARBONELL, L ;
PUIGBO, JJ ;
MUNOZ, S .
AMERICAN HEART JOURNAL, 1961, 62 (03) :406-&
[7]   PERCUTANEOUS BALLOON VALVULOPLASTY OF PULMONARY VALVE STENOSIS, DYSPLASIA, AND RESIDUAL STENOSIS AFTER SURGICAL VALVOTOMY FOR PULMONARY ATRESIA WITH INTACT VENTRICULAR SEPTUM - LONG-TERM RESULTS [J].
BALLERINI, L ;
MULLINS, CE ;
CIFARELLI, A ;
PASQUINI, L ;
DESIMONE, G ;
GIANNICO, S ;
GUCCIONE, P ;
DIDONATO, R ;
DICARLO, D .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 19 (03) :165-169
[8]  
BECKER AE, 1971, ARCH PATHOL, V91, P167
[9]   CONGENITAL PULMONARY ATRESIA WITH TRICUSPID INSUFFICIENCY - MORPHOLOGIC STUDY [J].
BHARATI, S ;
MCALLISTER, HA ;
CHIEMMONGKOLTIP, P ;
LEV, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1977, 40 (01) :70-75
[10]  
BLACKMAN MS, 1981, BRIT HEART J, V46, P449