摘要
Purpose: Four-port bimanual vitrectomy is a surgical technique that facilitates removal of epiretinal membranes in severe proliferative diabetic retinopathy (PDR). As the illumination is held by the assistant through the fourth scleral incision, fibrovascular membranes are removed by bimanual manipulation techniques. The objective of this study was to evaluate the safety and efficacy of four-port bimanual 23-gauge vitrectomy for patients with tractional retinal detachment (TRD) in severe PDR. Methods: Retrospective, comparative, consecutive, interventional case series. Sixty-six eyes of 58 consecutive patients who underwent primary vitrectomy for severe diabetic TRD. Thirty-six eyes of 31 cases that were treated with four-port 23-gauge vitrectomy were compared with 30 eyes of 27 cases that were treated with 23-gauge pars plana vitrectomy (PPV). Main outcome measures were best-corrected visual acuity (BCVA), retinal status, intraocular pressure, and incidence of intraoperative and postoperative complications with at least 6 months of follow-up. Results: The primary and ultimate anatomic success rates (94.4% versus 93.3%, and 100% in both groups, respectively) and the mean BCVA changes did not differ significantly between groups. The whole surgical time and the membrane removal time were significantly (p < 0.001, respectively) shorter in the four-port 23-gauge group than in the 23-gauge group. There was no difference in the incidence of intraoperative and postoperative complications in both groups. Conclusions: Four-port bimanual 23-gauge vitrectomy offers comparable anatomic success and shortens the surgical time compared with conventional 23-gauge PPV in patients with TRD resulting from severe PDR.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 31 条
[1]  
ABRAMS GW, 1987, AM J OPHTHALMOL, V103, P302
[2]   The 'suck-and-cut' bimanual technique for delamination of fibrovascular membranes in proliferative diabetic retinopathy [J].
Cheema, Rizwan A. ;
Sengupta, Rita .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (02) :225-225
[3]   Twin lights: A new chandelier illumination for bimanual surgery [J].
Eckardt, C .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2003, 23 (06) :893-894
[4]   Outcomes of 25-gauge vitrectomy for proliferative diabetic retinopathy [J].
Farouk, Mahmoud Mohamed ;
Naito, Takeshi ;
Sayed, Khulood Mohammed ;
Nagasawa, Toshihiko ;
Katome, Takashi ;
Radwan, Gamal ;
Abdallah, Ahmad ;
Elagouz, Mohamed .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (03) :369-376
[5]  
GONVERS M, 1987, ARCH OPHTHALMOL-CHIC, V105, P1292
[6]  
Holladay JT, 1997, J REFRACT SURG, V13, P388
[7]  
Horiguchi M, 2002, ARCH OPHTHALMOL-CHIC, V120, P491
[8]   20-, 23-, and 25-gauge vitreous cutters - Performance and characteristics evaluation [J].
Hubschman, Jean Pierre ;
Gupta, Anurag ;
Bourla, Dan H. ;
Culjat, Martin ;
Yu, Fei ;
Schwartz, Steven D. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2008, 28 (02) :249-257
[9]   Multicoated contact lens for bimanual vitreous surgery without endoillumination [J].
Kadonosono, K ;
Yabuki, K ;
Nishide, T ;
Nomura, E ;
Uchio, E ;
Yamakawa, T .
ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (03) :367-368
[10]   Comparison of visual function after epiretinal membrane removal by 20-gauge and 25-gauge vitrectomy [J].
Kadonosono, Kazuaki ;
Yamakawa, Tadashi ;
Uchio, Eiichi ;
Yanagi, Yasuo ;
Tamaki, Yasuhiro ;
Araie, Makoto .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 142 (03) :513-515