Visual performance and patient satisfaction of multifocal contact lenses in eyes undergoing monofocal intraocular Lens implantation

被引:5
作者
Kamiya, Kazutaka [1 ]
Fujimura, Fusako [1 ]
Ando, Wakako [2 ]
Iijima, Kei [2 ]
Shoji, Nobuyuki [2 ]
机构
[1] Kitasato Univ, Visual Physiol, Sch Allied Hlth Sci, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ, Sch Med, Dept Ophthalmol, Sagamihara, Kanagawa, Japan
关键词
Visual acuity; Higher-order aberrations; Intraocular scattering; Patient satisfaction; Cataract surgery; POWER PROFILES; DISSATISFACTION;
D O I
10.1016/j.clae.2020.03.013
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess visual performance and patient satisfaction of multifocal contact lenses in eyes having monofocal intraocular lens (IOL) implantation. Methods: We prospectively assessed uncorrected visual acuity at all distances (0.3, 0.4, 0.5, 0.7, 1, and 5 m), higher-order aberrations (HOAs), objective scattering index (OSI), contrast sensitivity, and patient satisfaction, before and during multifocal contact lenses wear in IOL-implanted eyes. Results: Visual acuity at 0.3, 0.4, 0.5, 0.7, 1, and 5 m during wearing multifocal contact lenses was 0.21 +/- 0.08, 0.11 +/- 0.06, 0.01 +/- 0.08, -0.02 +/- 0.10, -0.02 +/- 0.08, and -0.01 +/- 0.07, respectively. We found a significant improvement at near to intermediate distances (30, 40, and 50 cm), but no significant change at intermediate to far distances (70 cm, 1 m, and 5 m). Log contrast sensitivity significantly decreased at 6 and 12 cycles/degrees, but did not significantly change at 1.5, 3, and 18 cycles/degrees. Third-order aberrations significantly increased after CL treatment, but fourth-order aberrations or total higher-order aberrations did not significantly change during CL treatment. The OSI and log(s) did not significantly change during CL treatment. The patient satisfaction score for overall vision significantly improved during CL treatment. Conclusions: Multifocal contact lenses significantly improved visual acuity at near to intermediate distances, and subsequent patient satisfaction, even though contrast sensitivity function slightly decreased, suggesting its viability of presbyopic correction in monofocal IOL-implanted eyes.
引用
收藏
页码:218 / 221
页数:4
相关论文
共 20 条
[1]   Corneal aberrations and visual performance after radial keratotomy [J].
Applegate, RA ;
Howland, HC ;
Sharp, RP ;
Cottingham, AJ ;
Yee, RW .
JOURNAL OF REFRACTIVE SURGERY, 1998, 14 (04) :397-407
[2]   An Objective Scatter Index Based on Double-Pass Retinal Images of a Point Source to Classify Cataracts [J].
Artal, Pablo ;
Benito, Antonio ;
Perez, Guillermo M. ;
Alcon, Encarna ;
De Casas, Alvaro ;
Pujol, Jaume ;
Marin, Jose M. .
PLOS ONE, 2011, 6 (02)
[3]   Contact lens correction of presbyopia [J].
Bennett, Edward S. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2008, 91 (03) :265-278
[4]   Multifocal versus monofocal intraocular lenses for age-related cataract patients: a system review and meta-analysis based on randomized controlled trials [J].
Cao, Kai ;
Friedman, David S. ;
Jin, Shanshan ;
Yusufu, Mayinuer ;
Zhang, Jingshang ;
Wang, Jinda ;
Hou, Simeng ;
Zhu, Guyu ;
Wang, Bingsong ;
Xiong, Ying ;
Li, Jing ;
Li, Xiaoxia ;
He, Hailong ;
Chai, Lijing ;
Wan, Xiu Hua .
SURVEY OF OPHTHALMOLOGY, 2019, 64 (05) :647-658
[5]   Reliability of the compensation comparison method for measuring retinal stray light studied using Monte-Carlo simulations [J].
Coppens, Joris E. ;
Franssen, Luuk ;
van den Berg, Thomas J. T. P. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (05)
[6]   Multifocal versus monofocal intraocular lenses after cataract extraction [J].
de Silva, Samantha R. ;
Evans, Jennifer R. ;
Kirthi, Varo ;
Ziaei, Mohammed ;
Leyland, Martin .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (12)
[7]   Dissatisfaction after implantation of multifocal intraocular lenses [J].
de Vries, Niels E. ;
Webers, Carroll A. B. ;
Touwslager, Wouter R. H. ;
Bauer, Noel J. C. ;
de Brabander, John ;
Berendschot, Tos T. ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) :859-865
[8]   Compensation comparison method for assessment of retinal straylight [J].
Franssen, L ;
Coppens, JE ;
van den Berg, TJTP .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (02) :768-776
[9]   Optical Quality Analysis System:: Instrument for objective clinical evaluation of ocular optical quality [J].
Güell, JL ;
Pujol, J ;
Arjona, M ;
Diaz-Douton, F ;
Artal, P .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07) :1598-1599
[10]  
Kaida T., 2019, EYE CONTACT LENS, V10