The wear of fixed and mobile bearing unicompartmental knee replacements

被引:29
作者
Brockett, C. L. [1 ]
Jennings, L. M. [1 ]
Fisher, J. [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
knee replacement; wear; arthroplasty; in vitro; unicompartmental; MOLECULAR-WEIGHT POLYETHYLENE; FOLLOW-UP; ARTHROPLASTY; KINEMATICS; PROSTHESES; OSTEOARTHRITIS; SIMULATOR; JOINT;
D O I
10.1177/2041303310393824
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Unicompartmental knee replacements (UKR) are an option for surgical intervention for the treatment of single-compartment osteoarthritis. The aim of this study was to compare the wear of a low-conformity fixed-bearing UKR with a conforming mobile bearing UKR under two kinematic conditions, to investigate the effect of implant design and kinematics on wear performance in a physiological knee wear simulator. Under both sets of kinematic conditions, the relatively low-conforming fixed UKR showed lower wear, compared with the more conforming anterior-posterior sliding mobile bearing. However, it should be noted that differences in materials between the two designs also contribute to the relative wear performance of the bearings. The combined wear of the medial and lateral bearings of the fixed-bearing UKR as a 'total knee' were significantly reduced compared with a fixed-bearing total knee replacement studied under the same kinematic conditions.
引用
收藏
页码:511 / 519
页数:9
相关论文
共 43 条
  • [11] Unicompartmental knee arthroplasty surgery - 10-year minimum follow-up period
    Cartier, P
    Sanouiller, JL
    Grelsamer, RP
    [J]. JOURNAL OF ARTHROPLASTY, 1996, 11 (07) : 782 - 788
  • [12] Collier J.P., 2003, CLIN ORTHOP RELAT R, V414, P289
  • [13] FISHER J, 2004, CLIN ORTHOP RELAT R, V428, P114
  • [14] FISHER J, 2010, CORROSION, V46, P12
  • [15] Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses
    Galvin, Alison L.
    Kang, Lu
    Udofia, Itoro
    Jennings, Louise M.
    McEwen, Hannah M. J.
    Jin, Zhongmin
    Fisher, John
    [J]. JOURNAL OF BIOMECHANICS, 2009, 42 (12) : 1898 - 1902
  • [16] Gioe T J., 2004, Clinical Orthopaedics Related Research November, V428, P100
  • [17] HECK DA, 1993, CLIN ORTHOP RELAT R, V286, P154
  • [18] Preliminary tribological evaluation of nanostructured diamond coatings against ultra-high molecular weight polyethylene
    Hill, Michael R.
    Catledge, Shane A.
    Konovalov, Valeriy
    Clem, William C.
    Chowdhury, Shafiul A.
    Etheridge, Brandon S.
    Stanishevsky, Andrei
    Lemons, Jack E.
    Vohra, Yogesh K.
    Eberhardt, Alan W.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 85B (01) : 140 - 148
  • [19] Biological reactions to wear debris in total joint replacement
    Ingham, E
    Fisher, J
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) : 21 - 37
  • [20] INSALL J, 1976, CLIN ORTHOP RELAT R, V120, P83