The wear of fixed and mobile bearing unicompartmental knee replacements

被引:29
作者
Brockett, C. L. [1 ]
Jennings, L. M. [1 ]
Fisher, J. [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
knee replacement; wear; arthroplasty; in vitro; unicompartmental; MOLECULAR-WEIGHT POLYETHYLENE; FOLLOW-UP; ARTHROPLASTY; KINEMATICS; PROSTHESES; OSTEOARTHRITIS; SIMULATOR; JOINT;
D O I
10.1177/2041303310393824
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Unicompartmental knee replacements (UKR) are an option for surgical intervention for the treatment of single-compartment osteoarthritis. The aim of this study was to compare the wear of a low-conformity fixed-bearing UKR with a conforming mobile bearing UKR under two kinematic conditions, to investigate the effect of implant design and kinematics on wear performance in a physiological knee wear simulator. Under both sets of kinematic conditions, the relatively low-conforming fixed UKR showed lower wear, compared with the more conforming anterior-posterior sliding mobile bearing. However, it should be noted that differences in materials between the two designs also contribute to the relative wear performance of the bearings. The combined wear of the medial and lateral bearings of the fixed-bearing UKR as a 'total knee' were significantly reduced compared with a fixed-bearing total knee replacement studied under the same kinematic conditions.
引用
收藏
页码:511 / 519
页数:9
相关论文
共 43 条
  • [1] [Anonymous], 2002, 142431 ISO
  • [2] The unicompartmental knee - Design and technical considerations in minimizing wear
    Argenson, Jean-Noel A.
    Parratte, Sebastien
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 137 - 142
  • [3] Dose effects of cross-linking polyethylene for total knee arthroplasty on wear performance and mechanical properties
    Asano, Taiyo
    Akagi, Masao
    Clarke, Ian C.
    Masuda, Shingo
    Ishii, Tsunehiro
    Nakamura, Takashi
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 83B (02) : 615 - 622
  • [4] Investigation of wear of knee prostheses in a new displacement/force-controlled simulator
    Barnett, PI
    McEwen, HMJ
    Auger, DD
    Stone, MH
    Ingham, E
    Fisher, J
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) : 51 - 61
  • [5] Comparison of wear in a total knee replacement under different kinematic conditions
    Barnett, PI
    Fisher, J
    Auger, DD
    Stone, MH
    Ingham, E
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (10-12) : 1039 - 1042
  • [6] BARTLEY RE, 1994, CLIN ORTHOP RELAT R, V299, P18
  • [7] Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses
    Blunn, GW
    Joshi, AB
    Minns, RJ
    Lidgren, L
    Lilley, P
    Ryd, L
    Engelbrecht, E
    Walker, PS
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (03) : 281 - 290
  • [8] Contemporary Unicompartmental Knee Arthroplasty
    Bonutti, Peter M.
    Dethmers, Daniel A.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07) : 24 - 27
  • [9] UNICOMPARTMENTAL REPLACEMENT AND HIGH TIBIAL OSTEOTOMY FOR OSTEOARTHRITIS OF THE KNEE - A COMPARATIVE-STUDY AFTER 5-10 YEARS FOLLOW-UP
    BROUGHTON, NS
    NEWMAN, JH
    BAILY, RAJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03): : 447 - 452
  • [10] BURTON A, 2006, P 52 M ORS CHIC US, P563