Bone cell-materials interactions and Ni ion release of anodized equiatomic NiTi alloy

被引:85
作者
Bernard, Sheldon A. [1 ]
Balla, Vamsi Krishna [1 ]
Davies, Neal M. [2 ]
Bose, Susmita [1 ]
Bandyopadhyay, Amit [1 ]
机构
[1] Washington State Univ, Sch Mech & Mat Engn, WM Keck Biomed Mat Res Lab, Pullman, WA 99164 USA
[2] Washington State Univ, Coll Pharm, Dept Pharmaceut Sci, Pullman, WA 99164 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
Nitinol; Surface modification; Anodization; Cell-material interactions; Ni release; SHAPE-MEMORY ALLOYS; SURFACE OXIDATION; TITANIUM; TANTALUM; HYDROXYAPATITE; FABRICATION; BEHAVIOR; BIOCOMPATIBILITY; ANODIZATION; LEUKOCYTES;
D O I
10.1016/j.actbio.2011.01.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A laser processed NiTi alloy was anodized for different times in H2SO4 electrolyte with varying pH to create biocompatible surfaces with low Ni ion release as well as bioactive surfaces to enhance biocompatibility and bone cell-material interactions. The anodized surfaces were assessed for their in vitro cell-material interactions using human fetal osteoblast (hFOB) cells for 3, 7 and 11 days, and Ni ion release up to 8 weeks in simulated body fluids. The results were correlated with the surface morphologies of anodized surfaces characterized using field-emission scanning electron microscopy (FESEM). The results show that anodization creates a surface with nano/micro-roughness depending on the anodization conditions. The hydrophilicity of the NiTi surface was found to improve after anodization, as shown by the lower contact angles in cell medium, which dropped from 32 degrees to < 5 degrees. The improved wettability of anodized surfaces is further corroborated by their high surface energy, comparable with that of commercially pure Ti. Relatively high surface energies, especially the polar component, and nano/micro surface features of anodized surfaces significantly increased the number of living cells and their adherence and growth on these surfaces. Finally, a significant drop in Ni ion release from 268 +/- 11 to 136 +/- 15 ppb was observed for NiTi surfaces after anodization. This work indicates that anodization of a NiTi alloy has a positive influence on the surface energy and surface morphology, which in turn improves bone cell-material interactions and reduces Ni ion release in vitro. (C) 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1902 / 1912
页数:11
相关论文
共 54 条
[1]  
Anselme K, 2000, J BIOMED MATER RES, V49, P155, DOI 10.1002/(SICI)1097-4636(200002)49:2<155::AID-JBM2>3.0.CO
[2]  
2-J
[3]  
Balla V.K., 2007, METALL MATER TRANS A, V38A, P1096
[4]   Porous tantalum structures for bone implants: Fabrication, mechanical and in vitro biological properties [J].
Balla, Vamsi Krishna ;
Bodhak, Subhadip ;
Bose, Susmita ;
Bandyopadhyay, Amit .
ACTA BIOMATERIALIA, 2010, 6 (08) :3349-3359
[5]   Direct laser processing of a tantalum coating on titanium for bone replacement structures [J].
Balla, Vamsi Krishna ;
Banerjee, Shashwat ;
Bose, Susmita ;
Bandyopadhyay, Amit .
ACTA BIOMATERIALIA, 2010, 6 (06) :2329-2334
[6]   Laser-assisted Zr/ZrO2 coating on Ti for load-bearing implants [J].
Balla, Vamsi Krishna ;
Xue, Weichang ;
Bose, Susmita ;
Bandyopadhyay, Amit .
ACTA BIOMATERIALIA, 2009, 5 (07) :2800-2809
[7]   Fabrication of compositionally and structurally graded Ti-TiO2 structures using laser engineered net shaping (LENS) [J].
Balla, Vamsi Krishna ;
DeVasConCellos, Paul Duteil ;
Xue, Weichang ;
Bose, Susmita ;
Bandyopadhyay, Amit .
ACTA BIOMATERIALIA, 2009, 5 (05) :1831-1837
[8]   Application of Laser Engineered Net Shaping (LENS) to manufacture porous and functionally graded structures for load bearing implants [J].
Bandyopadhyay, Amit ;
Krishna, B. V. ;
Xue, Weichang ;
Bose, Susmita .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2009, 20 :29-34
[9]   Characterisation of surface oxidation of nickel-titanium alloy by ion-beam and electrochemical techniques [J].
Barison, S ;
Cattarin, S ;
Daolio, S ;
Musiani, M ;
Tuissi, A .
ELECTROCHIMICA ACTA, 2004, 50 (01) :11-18
[10]   ESTABLISHMENT OF NICKEL-SPECIFIC T-CELL LINES FROM PATIENTS WITH ALLERGIC CONTACT-DERMATITIS - COMPARISON OF DIFFERENT PROTOCOLS [J].
BOUR, H ;
NICOLAS, JF ;
GARRIGUE, JL ;
DEMIDEM, A ;
SCHMITT, D .
CLINICAL IMMUNOLOGY AND IMMUNOPATHOLOGY, 1994, 73 (01) :142-145