Design and testing of a controlled electromagnetic spinal cord impactor for use in large animal models of acute traumatic spinal cord injury

被引:3
|
作者
Petteys, Rory J. [1 ,4 ]
Spitz, Steven M. [2 ]
Syed, Hasan [2 ]
Rice, R. Andrew [2 ]
Sarabia-Estrada, Rachel [1 ]
Goodwin, C. Rory [1 ]
Sciubba, Daniel M. [1 ]
Freedman, Brett A. [3 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Neurosurg, Baltimore, MD 21205 USA
[2] Georgetown Univ Hosp, Dept Neurosurg, Washington, DC 20007 USA
[3] Mayo Clin, Sch Med, Dept Orthoped Surg, Rochester, MN USA
[4] William Beaumont Army Med Ctr, Div Neurosurg, 5005 N Piedras St, El Paso, TX 79920 USA
关键词
Spinal cord injury; Animal model; Large animal research; Spinal cord impactor; COMPRESSION; RECOVERY; MINIPIGS;
D O I
10.1016/j.jocn.2017.04.031
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Spinal cord injury (SCI) causes debilitating neurological dysfunction and has been observed in warfighters injured in IED blasts. Clinical benefit of SCI treatment remains elusive and better large animal models are needed to assess treatment options. Here, we describe a controlled electromagnetic spinal cord impactor for use in large animal models of SO. Methods: A custom spinal cord impactor and platform were fabricated for large animals (e.g., pig, sheep, dog, etc.). Impacts were generated by a voice coil actuator; force and displacement were measured with a load cell and potentiometer respectively. Labview (National Instruments, Austin, TX) software was used to control the impact cycle and import force and displacement data. Software finite impulse response (FIR) filtering was employed for all input data. Silicon tubing was used a surrogate for spinal cord in order to test the device; repeated impacts were performed at 15, 25, and 40 Newtons. Results: Repeated impacts demonstrated predictable results at each target force. The average duration of impact was 71.2 +/- 6.1 ms. At a target force of 40 N, the output force was 41.5 +/- 0.7 N. With a target of 25 N, the output force was 23.5 +/- 0.6 N; a target of 15 Newtons revealed an output force of 15.2 +/- 1.4 N. The calculated acceleration range was 12.5-21.2 m/s(2). Conclusions: This custom spinal cord impactor reliably delivers precise impacts to the spinal cord and will be utilized in future research to study acute traumatic SCI in a large animal. Published by Elsevier Ltd.
引用
收藏
页码:229 / 234
页数:6
相关论文
共 50 条
  • [1] Behavioral testing in animal models of spinal cord injury
    Fouad, K.
    Ng, C.
    Basso, D. M.
    EXPERIMENTAL NEUROLOGY, 2020, 333
  • [2] Large animal and primate models of spinal cord injury for the testing of novel therapies
    Kwon, Brian K.
    Streijger, Femke
    Hill, Caitlin E.
    Anderson, Aileen J.
    Bacon, Mark
    Beattie, Michael S.
    Blesch, Armin
    Bradbury, Elizabeth J.
    Brown, Arthur
    Bresnahan, Jacqueline C.
    Case, Casey C.
    Colburn, Raymond W.
    David, Samuel
    Fawcett, James W.
    Ferguson, Adam R.
    Fischer, Itzhak
    Floyd, Candace L.
    Gensel, John C.
    Houle, John D.
    Jakeman, Lyn B.
    Jeffery, Nick D.
    Jones, Linda Ann Truett
    Kleitman, Naomi
    Kocsis, Jeffery
    Lu, Paul
    Magnuson, David S. K.
    Marsala, Martin
    Moore, Simon W.
    Mothe, Andrea J.
    Oudega, Martin
    Plant, Giles W.
    Rabchevsky, Alexander Sasha
    Schwab, Jan M.
    Silver, Jerry
    Steward, Oswald
    Xu, Xiao-Ming
    Guest, James D.
    Tetzlaff, Wolfram
    EXPERIMENTAL NEUROLOGY, 2015, 269 : 154 - 168
  • [3] Evolution of Spinal Cord Swelling in Acute Traumatic Spinal Cord Injury
    Asif, Hasan
    Visagan, Ravindran
    Boseta, Ellaine
    Zoumprouli, Argyro
    Papadopoulos, Marios C.
    Saadoun, Samira
    NEUROTRAUMA REPORTS, 2025, 6 (01): : 158 - 170
  • [4] Acute Traumatic Spinal Cord Injury
    Taylor, Elizabeth C.
    Fitzpatrick, Casey E.
    Thompson, Stasia E.
    Justice, Stephanie Baker
    ADVANCED EMERGENCY NURSING JOURNAL, 2022, 44 (04) : 272 - 280
  • [5] Acute Traumatic Spinal Cord Injury
    Eli, Ilyas
    Lerner, David P.
    Ghogawala, Zoher
    NEUROLOGIC CLINICS, 2021, 39 (02) : 471 - 488
  • [6] Longitudinal multiparametric MRI of traumatic spinal cord injury in animal models
    Chen, Li Min
    Wang, Feng
    Mishra, Arabinda
    Yang, Pai-Feng
    Sengupta, Anirban
    Reed, Jamie L.
    Gore, John C.
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 184 - 200
  • [7] Spinal fixation surgery for acute traumatic spinal cord injury
    Bagnall, A. M.
    Jones, L.
    Duffy, S.
    Riemsma, R. P.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2008, (01):
  • [8] Management of Acute Traumatic Spinal Cord Injury
    Grant, Ryan A.
    Quon, Jennifer L.
    Abbed, Khalid M.
    CURRENT TREATMENT OPTIONS IN NEUROLOGY, 2015, 17 (02)
  • [9] Management of Acute Traumatic Spinal Cord Injury
    Ryan A. Grant
    Jennifer L. Quon
    Khalid M. Abbed
    Current Treatment Options in Neurology, 2015, 17
  • [10] Animal models in spinal cord injury: A review
    Akhtar, Aysha Z.
    Pippin, John J.
    Sandusky, Chad B.
    REVIEWS IN THE NEUROSCIENCES, 2008, 19 (01) : 47 - 60