High-flow nasal cannula therapy, factors affecting effective inspired oxygen fraction: an experimental adult bench model

被引:9
作者
Duprez, Frederic [1 ,5 ]
de Terwangne, C. [2 ]
Bellemans, V. [1 ]
Poncin, W. [3 ]
Reychler, G. [3 ]
Sorgente, A. [4 ]
Cuvelier, G. [5 ]
Mashayekhi, S. [1 ]
Wittebole, X. [6 ]
机构
[1] Ctr Hosp Epicura, Dept Intens Care, Hornu, Belgium
[2] Clin Univ St Luc, Dept Geriatr Med, Brussels, Belgium
[3] Catholic Univ Louvain, Dept Internal Med, Brussels, Belgium
[4] Ctr Hosp Epicura, Dept Cardiol, Hornu, Belgium
[5] Condorcet Sch, Lab Resp Physiol, Tournai, Belgium
[6] UCLouvain, Clin Univ St Luc, Dept Intens Care, Brussels, Belgium
关键词
Oxygenation through High Flow Delivery Systems; HFO; HFNC; Inspiratory flow; Minute ventilation; Effective inspired oxygen fraction; Double trunk mask; PRESSURE;
D O I
10.1007/s10877-021-00784-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Oxygenation through High Flow Delivery Systems (HFO) is described as capable of delivering accurate F-i(O2). Meanwhile, peak inspiratory flow <(V) over dot>(I)) of patients with acute hypoxemic respiratory failure can reach up to 120 L/min, largely exceeding HFO flow. Currently, very few data on the reliability of HFO devices at these high <(V) over dot>(I) are available. We sought to evaluate factors affecting oxygenation while using HFO systems at high <(V) over dot>(I) in a bench study. Spontaneous breathing was generated with a mechanical test lung connected to a mechanical ventilator Servo-i (R), set to volume control mode. Gas flow from a HFO device was delivered to the test lung. The influence on effective inspired oxygen fraction of three parameters (F-i(O2) 0.6, 0.8, and 1, <(V) over dot>(I) from 28 to 98.1 L/min, and HFO Gas Flows from 40 to 60 L/min) were analyzed and are reported. The present bench study demonstrates that during HFO treatment, measured F-i(O2) in the lung does not equal set F-i(O2) on the device. The substance of this variation (Delta F-i(O2)) is tightly correlated to <(V) over dot>(I) (Pearson's coefficient of 0.94, p-value< 0.001). Additionally, set F-i(O2) and Flow at HFO device appear to significatively affect Delta F-i(O2) as well (p-values < 0.001, adjusted to <(V) over dot>(I)). The result of multivariate linear regression indicates predictors (<(V) over dot>(I), Flow and set F-i(O2)) to explain 92% of the variance of delta F-i(O2) through K-Fold Cross Validation. Moreover, adjunction of a dead space in the breathing circuit significantly decreased Delta F-i(O2) (p <0.01). The present bench study did expose a weakness of HFO devices in reliability of delivering accurate F-I(O2) at high <(V) over dot>(I) as well as, to a lesser extent, at <(V) over dot>(I) below equivalent set HFO Flows. Moreover, set HFO flow and set F-I(O2) did influence the variability of effective inspired oxygen fraction. The adjunction of a dead space in the experimental set-up significantly amended this variability and should thus be further studied in order to improve success rate of HFO therapy.
引用
收藏
页码:1441 / 1448
页数:8
相关论文
共 50 条
[1]   High-flow nasal cannula therapy, factors affecting effective inspired oxygen fraction: an experimental adult bench model [J].
Frédéric Duprez ;
C. de Terwangne ;
V. Bellemans ;
W. Poncin ;
G. Reychler ;
A. Sorgente ;
G. Cuvelier ;
S. Mashayekhi ;
X. Wittebole .
Journal of Clinical Monitoring and Computing, 2022, 36 :1441-1448
[2]   High-flow nasal cannula oxygen therapy for modified electroconvulsive therapy [J].
Karim, Habib M. R. ;
Esquinas, Antonio M. .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (01) :56-57
[3]   Noise Exposure From High-Flow Nasal Cannula Oxygen Therapy: A Bench Study on Noise Reduction [J].
Kubo, Takamitsu ;
Nakajima, Hiroaki ;
Shimoda, Ryo ;
Seo, Tatsuya ;
Kanno, Yurie ;
Kondo, Toshikazu ;
Tamai, Sunao .
RESPIRATORY CARE, 2018, 63 (03) :267-273
[4]   Reply to: high-flow nasal cannula oxygen therapy for modified electroconvulsive therapy [J].
Zhu, Yi ;
Kang, Yin ;
Wei, Jinfeng ;
Wang, Sheng .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (01) :57-58
[5]   Humidity and Inspired Oxygen Concentration During High-Flow Nasal Cannula Therapy in Neonatal and Infant Lung Models [J].
Chikata, Yusuke ;
Ohnishi, Saki ;
Nishimura, Masaji .
RESPIRATORY CARE, 2017, 62 (05) :532-537
[6]   High-Flow Nasal Cannula Oxygen Therapy in the Management of Respiratory Failure: A Review [J].
Mukherjee, Deyashini ;
Mukherjee, Rahul .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (12)
[7]   Oxygen Therapy with High-Flow Nasal Cannula as an Effective Treatment for Perioperative Pneumocephalus: Case Illustrations and Pathophysiological Review [J].
Siegel, Jason L. ;
Hampton, Karen ;
Rabinstein, Alejandro A. ;
McLaughlin, Diane ;
Diaz-Gomez, Jose L. .
NEUROCRITICAL CARE, 2018, 29 (03) :366-373
[8]   The Use of High-Flow Nasal Cannula Oxygen Outside the ICU [J].
Zemach, Sasson ;
Helviz, Yigal ;
Shitrit, Michal ;
Friedman, Reuven ;
Levin, Phillip D. .
RESPIRATORY CARE, 2019, 64 (11) :1333-1342
[9]   Comparison of the Efficacies of High-Flow Nasal Cannula Oxygen Therapy and Non-invasive Nasal Cannula Ventilation in Preventing Intubation [J].
Barlas, Ulkem Kocoglu ;
Ozel, Abdulrahman ;
Tosun, Volkan ;
Bozkurt, Emine Ufuk ;
Kihtir, Hasan Serdar .
TURKISH ARCHIVES OF PEDIATRICS, 2024, 59 (02) :214-220
[10]   A Retrospective Cohort Study of High-Flow Nasal Cannula Oxygen and Swallowing [J].
Ellsworth, Cintamani H. ;
Bartlett, Rebecca S. .
RESPIRATORY CARE, 2025, 70 (05) :485-491