High-flow nasal cannula therapy, factors affecting effective inspired oxygen fraction: an experimental adult bench model

被引:9
作者
Duprez, Frederic [1 ,5 ]
de Terwangne, C. [2 ]
Bellemans, V. [1 ]
Poncin, W. [3 ]
Reychler, G. [3 ]
Sorgente, A. [4 ]
Cuvelier, G. [5 ]
Mashayekhi, S. [1 ]
Wittebole, X. [6 ]
机构
[1] Ctr Hosp Epicura, Dept Intens Care, Hornu, Belgium
[2] Clin Univ St Luc, Dept Geriatr Med, Brussels, Belgium
[3] Catholic Univ Louvain, Dept Internal Med, Brussels, Belgium
[4] Ctr Hosp Epicura, Dept Cardiol, Hornu, Belgium
[5] Condorcet Sch, Lab Resp Physiol, Tournai, Belgium
[6] UCLouvain, Clin Univ St Luc, Dept Intens Care, Brussels, Belgium
关键词
Oxygenation through High Flow Delivery Systems; HFO; HFNC; Inspiratory flow; Minute ventilation; Effective inspired oxygen fraction; Double trunk mask; PRESSURE;
D O I
10.1007/s10877-021-00784-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Oxygenation through High Flow Delivery Systems (HFO) is described as capable of delivering accurate F-i(O2). Meanwhile, peak inspiratory flow <(V) over dot>(I)) of patients with acute hypoxemic respiratory failure can reach up to 120 L/min, largely exceeding HFO flow. Currently, very few data on the reliability of HFO devices at these high <(V) over dot>(I) are available. We sought to evaluate factors affecting oxygenation while using HFO systems at high <(V) over dot>(I) in a bench study. Spontaneous breathing was generated with a mechanical test lung connected to a mechanical ventilator Servo-i (R), set to volume control mode. Gas flow from a HFO device was delivered to the test lung. The influence on effective inspired oxygen fraction of three parameters (F-i(O2) 0.6, 0.8, and 1, <(V) over dot>(I) from 28 to 98.1 L/min, and HFO Gas Flows from 40 to 60 L/min) were analyzed and are reported. The present bench study demonstrates that during HFO treatment, measured F-i(O2) in the lung does not equal set F-i(O2) on the device. The substance of this variation (Delta F-i(O2)) is tightly correlated to <(V) over dot>(I) (Pearson's coefficient of 0.94, p-value< 0.001). Additionally, set F-i(O2) and Flow at HFO device appear to significatively affect Delta F-i(O2) as well (p-values < 0.001, adjusted to <(V) over dot>(I)). The result of multivariate linear regression indicates predictors (<(V) over dot>(I), Flow and set F-i(O2)) to explain 92% of the variance of delta F-i(O2) through K-Fold Cross Validation. Moreover, adjunction of a dead space in the breathing circuit significantly decreased Delta F-i(O2) (p <0.01). The present bench study did expose a weakness of HFO devices in reliability of delivering accurate F-I(O2) at high <(V) over dot>(I) as well as, to a lesser extent, at <(V) over dot>(I) below equivalent set HFO Flows. Moreover, set HFO flow and set F-I(O2) did influence the variability of effective inspired oxygen fraction. The adjunction of a dead space in the experimental set-up significantly amended this variability and should thus be further studied in order to improve success rate of HFO therapy.
引用
收藏
页码:1441 / 1448
页数:8
相关论文
共 15 条
[11]   High-flow nasal cannula oxygen therapy in adults [J].
Nishimura M. .
Journal of Intensive Care, 3 (1)
[12]   Acute Respiratory Distress Syndrome The Berlin Definition [J].
Ranieri, V. Marco ;
Rubenfeld, Gordon D. ;
Thompson, B. Taylor ;
Ferguson, Niall D. ;
Caldwell, Ellen ;
Fan, Eddy ;
Camporota, Luigi ;
Slutsky, Arthur S. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (23) :2526-2533
[13]   An Index Combining Respiratory Rate and Oxygenation to Predict Outcome of Nasal High-Flow Therapy [J].
Roca, Oriol ;
Caralt, Berta ;
Messika, Jonathan ;
Samper, Manuel ;
Sztrymf, Benjamin ;
Hernandez, Gonzalo ;
Garcia-de-Acilu, Marina ;
Frat, Jean-Pierre ;
Masclans, Joan R. ;
Ricard, Jean-Damien .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199 (11) :1368-1376
[14]   The SOFA (sepsis-related organ failure assessment) score to describe organ dysfunction/failure [J].
Vincent, JL ;
Moreno, R ;
Takala, J ;
Willatts, S ;
DeMendonca, A ;
Bruining, H ;
Reinhart, CK ;
Suter, PM ;
Thijs, LG .
INTENSIVE CARE MEDICINE, 1996, 22 (07) :707-710
[15]   High-Flow Oxygen Administration by Nasal Cannula for Adult and Perinatal Patients [J].
Ward, Jeffrey J. .
RESPIRATORY CARE, 2013, 58 (01) :98-120