High-flow nasal cannula therapy, factors affecting effective inspired oxygen fraction: an experimental adult bench model

被引:9
作者
Duprez, Frederic [1 ,5 ]
de Terwangne, C. [2 ]
Bellemans, V. [1 ]
Poncin, W. [3 ]
Reychler, G. [3 ]
Sorgente, A. [4 ]
Cuvelier, G. [5 ]
Mashayekhi, S. [1 ]
Wittebole, X. [6 ]
机构
[1] Ctr Hosp Epicura, Dept Intens Care, Hornu, Belgium
[2] Clin Univ St Luc, Dept Geriatr Med, Brussels, Belgium
[3] Catholic Univ Louvain, Dept Internal Med, Brussels, Belgium
[4] Ctr Hosp Epicura, Dept Cardiol, Hornu, Belgium
[5] Condorcet Sch, Lab Resp Physiol, Tournai, Belgium
[6] UCLouvain, Clin Univ St Luc, Dept Intens Care, Brussels, Belgium
关键词
Oxygenation through High Flow Delivery Systems; HFO; HFNC; Inspiratory flow; Minute ventilation; Effective inspired oxygen fraction; Double trunk mask; PRESSURE;
D O I
10.1007/s10877-021-00784-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Oxygenation through High Flow Delivery Systems (HFO) is described as capable of delivering accurate F-i(O2). Meanwhile, peak inspiratory flow <(V) over dot>(I)) of patients with acute hypoxemic respiratory failure can reach up to 120 L/min, largely exceeding HFO flow. Currently, very few data on the reliability of HFO devices at these high <(V) over dot>(I) are available. We sought to evaluate factors affecting oxygenation while using HFO systems at high <(V) over dot>(I) in a bench study. Spontaneous breathing was generated with a mechanical test lung connected to a mechanical ventilator Servo-i (R), set to volume control mode. Gas flow from a HFO device was delivered to the test lung. The influence on effective inspired oxygen fraction of three parameters (F-i(O2) 0.6, 0.8, and 1, <(V) over dot>(I) from 28 to 98.1 L/min, and HFO Gas Flows from 40 to 60 L/min) were analyzed and are reported. The present bench study demonstrates that during HFO treatment, measured F-i(O2) in the lung does not equal set F-i(O2) on the device. The substance of this variation (Delta F-i(O2)) is tightly correlated to <(V) over dot>(I) (Pearson's coefficient of 0.94, p-value< 0.001). Additionally, set F-i(O2) and Flow at HFO device appear to significatively affect Delta F-i(O2) as well (p-values < 0.001, adjusted to <(V) over dot>(I)). The result of multivariate linear regression indicates predictors (<(V) over dot>(I), Flow and set F-i(O2)) to explain 92% of the variance of delta F-i(O2) through K-Fold Cross Validation. Moreover, adjunction of a dead space in the breathing circuit significantly decreased Delta F-i(O2) (p <0.01). The present bench study did expose a weakness of HFO devices in reliability of delivering accurate F-I(O2) at high <(V) over dot>(I) as well as, to a lesser extent, at <(V) over dot>(I) below equivalent set HFO Flows. Moreover, set HFO flow and set F-I(O2) did influence the variability of effective inspired oxygen fraction. The adjunction of a dead space in the experimental set-up significantly amended this variability and should thus be further studied in order to improve success rate of HFO therapy.
引用
收藏
页码:1441 / 1448
页数:8
相关论文
共 15 条
[1]   FIO2 in an Adult Model Simulating High-Flow Nasal Cannula Therapy [J].
Chikata, Yusuke ;
Onodera, Mutsuo ;
Oto, Jun ;
Nishimura, Masaji .
RESPIRATORY CARE, 2017, 62 (02) :193-198
[2]   The Double-Trunk Mask Improves Oxygenation During High-Flow Nasal Cannula Therapy for Acute Hypoxemic Respiratory Failure [J].
Duprez, Frederic ;
Bruyneel, Arnaud ;
Machayekhi, Shahram ;
Droguet, Marie ;
Bouckaert, Yves ;
Brimioulle, Serge ;
Cuvelier, Gregory ;
Reychler, Gregory .
RESPIRATORY CARE, 2019, 64 (08) :908-914
[3]   COVID-19 Does Not Lead to a "Typical" Acute Respiratory Distress Syndrome [J].
Gattinoni, Luciano ;
Coppola, Silvia ;
Cressoni, Massimo ;
Busana, Mattia ;
Rossi, Sandra ;
Chiumello, Davide .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201 (10) :1299-1300
[4]   Analysis of Hypoxic and Hypercapnic Ventilatory Response in Healthy Volunteers [J].
Goldberg, Shmuel ;
Ollila, Hanna Maria ;
Lin, Ling ;
Sharifi, Husham ;
Rico, Tom ;
Andlauer, Olivier ;
Aran, Adi ;
Bloomrosen, Efrat ;
Faraco, Juliette ;
Fang, Han ;
Mignot, Emmanuel .
PLOS ONE, 2017, 12 (01)
[5]   AMBIENT PRESSURE AIR OXYGEN BLENDER [J].
GUILLAUME, DW ;
DEVRIES, D .
JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (02) :153-156
[6]   INSPIRATORY WORK WITH AND WITHOUT CONTINUOUS POSITIVE AIRWAY PRESSURE IN PATIENTS WITH ACUTE RESPIRATORY-FAILURE [J].
KATZ, JA ;
MARKS, JD .
ANESTHESIOLOGY, 1985, 63 (06) :598-607
[7]   Physiologic effects of noninvasive ventilation during acute lung injury [J].
L'Her, E ;
Deye, N ;
Lellouche, F ;
Taille, S ;
Demoule, A ;
Fraticelli, A ;
Mancebo, J ;
Brochard, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2005, 172 (09) :1112-1118
[8]   Pre-hospital critical care management of severe hypoxemia in victims of Covid-19: a case series [J].
Maehlen, Jens Otto ;
Mikalsen, Roger ;
Heimdal, Hans Julius ;
Rehn, Marius ;
Hagemo, Jostein S. ;
Ottestad, William .
SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2021, 29 (01)
[9]   Surgical mask on top of high-flow nasal cannula improves oxygenation in critically ill COVID-19 patients with hypoxemic respiratory failure [J].
Montiel, Virginie ;
Robert, Arnaud ;
Robert, Annie ;
Nabaoui, Anas ;
Marie, Tourneux ;
Mestre, Natalia Morales ;
Guillaume, Maerckx ;
Laterre, Pierre-Francois ;
Wittebole, Xavier .
ANNALS OF INTENSIVE CARE, 2020, 10 (01)
[10]   High-Flow Nasal Cannula Oxygen Therapy in Adults: Physiological Benefits, Indication, Clinical Benefits, and Adverse Effects [J].
Nishimura, Masaji .
RESPIRATORY CARE, 2016, 61 (04) :529-541