Computer assisted determination of acetabular cup orientation using 2D-3D image registration

被引:7
作者
Zheng, Guoyan [1 ]
Zhang, Xuan [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, CH-3014 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
Post-operative cup orientation; X-ray radiograph; 2D-3D registration; Total hip arthroplasty; Pelvic tilt; TOTAL HIP-ARTHROPLASTY; CT; ANTEVERSION; PLACEMENT; COMPONENT; TILT; THA;
D O I
10.1007/s11548-010-0407-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background 2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations. Methods A new formulation for determination of postoperative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips. Results Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 +/- 0.7 degrees (range from 0.1 degrees to 2.0 degrees.) for inclination and 1.7 +/- 1.2 degrees (range from 0.0 degrees to 3.9 degrees) for anteversion, taking the measurements from postoperative CT images as ground truths. Conclusions Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of postoperative cup orientation and measurement of pelvic tilt and rotation.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 50 条
  • [41] Evaluation of 3D-2D Registration Methods for Registration of 3D-DSA and 2D-DSA Cerebral Images
    Mitrovic, Uros
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGING 2013: IMAGE PROCESSING, 2013, 8669
  • [42] An intensity-based registration algorithm for probabilistic images and its application for 2-D to 3-D image registration
    Rohlfing, T
    Russakoff, DB
    Murphy, MJ
    Maurer, CR
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 581 - 591
  • [43] A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image
    Naik, Roshan Ramakrishna
    Hoblidar, Anitha
    Bhat, Shyamasunder N.
    Ampar, Nishanth
    Kundangar, Raghuraj
    JOURNAL OF IMAGING, 2022, 8 (07)
  • [44] Key Technologies for Building Universal Platform for 2D/3D Medical Image Registration
    Zhao, Li-ya
    Jia, Ke-bin
    2013 NINTH INTERNATIONAL CONFERENCE ON INTELLIGENT INFORMATION HIDING AND MULTIMEDIA SIGNAL PROCESSING (IIH-MSP 2013), 2013, : 169 - 172
  • [45] Cup Implant Planning Based on 2-D/3-D Radiographic Pelvis Reconstruction-First Clinical Results
    Schumann, Steffen
    Sato, Yoshinobu
    Nakanishi, Yuki
    Yokota, Futoshi
    Takao, Masaki
    Sugano, Nobuhiko
    Zheng, Guoyan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (11) : 2665 - 2673
  • [46] 3D-2D image registration in the presence of soft-tissue deformation in image-guided transbronchial interventions
    Vijayan, R.
    Sheth, N.
    Mekki, L.
    Lu, A.
    Uneri, A.
    Sisniega, A.
    Magaraggia, J.
    Kleinszig, G.
    Vogt, S.
    Thiboutot, J.
    Lee, H.
    Yarmus, L.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (01)
  • [47] 3D Point Cloud Analysis of Structured Light Registration in Computer assisted Navigation in Spinal Surgeries
    Gupta, Shaurya
    Guha, Daipayan
    Jakubovic, Raphael
    Yang, Victor X. D.
    CLINICAL AND TRANSLATIONAL NEUROPHOTONICS, 2017, 10050
  • [48] Pelvic tilt and functional acetabular position after total hip arthroplasty: an EOS 2D/3D radiographic study
    Loppini, Mattia
    Pisano, Alessandro
    Ruggeri, Riccardo
    Della Rocca, Antonello
    Grappiolo, Guido
    HIP INTERNATIONAL, 2023, 33 (03) : 365 - 370
  • [49] Evaluation of Four Similarity Measures for 2D/3D Registration in Image-Guided Intervention
    Wang, Lei
    Gao, Xin
    Zhou, Zhiyong
    Wang, Xiaocong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (03) : 416 - 421
  • [50] Intraoperative 2D/3D Image Registration via Differentiable X-ray Rendering
    Gopalakrishnan, Vivek
    Dey, Neel
    Golland, Polina
    2024 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2024, : 11662 - 11672