Computer assisted determination of acetabular cup orientation using 2D-3D image registration

被引:7
作者
Zheng, Guoyan [1 ]
Zhang, Xuan [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, CH-3014 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
Post-operative cup orientation; X-ray radiograph; 2D-3D registration; Total hip arthroplasty; Pelvic tilt; TOTAL HIP-ARTHROPLASTY; CT; ANTEVERSION; PLACEMENT; COMPONENT; TILT; THA;
D O I
10.1007/s11548-010-0407-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background 2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations. Methods A new formulation for determination of postoperative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips. Results Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 +/- 0.7 degrees (range from 0.1 degrees to 2.0 degrees.) for inclination and 1.7 +/- 1.2 degrees (range from 0.0 degrees to 3.9 degrees) for anteversion, taking the measurements from postoperative CT images as ground truths. Conclusions Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of postoperative cup orientation and measurement of pelvic tilt and rotation.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 50 条
  • [31] 2D measurements of cup orientation are less reliable than 3D measurements
    Davda, Kinner
    Smyth, Niall
    Cobb, Justin P.
    Hart, Alister J.
    ACTA ORTHOPAEDICA, 2016, 87 (03) : 314 - 317
  • [32] Evaluation of similarity measures for 3D/2D image registration
    Skerl, Darko
    Likar, Bostjan
    Pernus, Franjo
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [33] Non-rigid free-form 2D-3D registration using a B-spline-based statistical deformation model
    Yu, Weimin
    Tannast, Moritz
    Zheng, Guoyan
    PATTERN RECOGNITION, 2017, 63 : 689 - 699
  • [34] A comparative analysis of intensity-based 2D-3D registration for intraoperative use in pedicle screw insertion surgeries
    Esfandiari, Hooman
    Anglin, Carolyn
    Guy, Pierre
    Street, John
    Weidert, Simon
    Hodgson, Antony J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (10) : 1725 - 1739
  • [35] Evaluation of optimization methods for intensity-based 2D-3D registration in x-ray guided interventions
    van der Bom, I. M. J.
    Klein, S.
    Staring, M.
    Homan, R.
    Bartels, L. W.
    Pluim, J. P. W.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [36] Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy
    Wu, Jian
    Kim, Minho
    Peters, Jorg
    Chung, Heeteak
    Samant, Sanjiv S.
    MEDICAL PHYSICS, 2009, 36 (12) : 5391 - 5403
  • [37] Measurement of the Acetabular Cup Orientation After Total Hip Arthroplasty Based on 3-Dimensional Reconstruction From a Single X-Ray Image Using Generative Adversarial Networks
    Fujita, Akira
    Goto, Koji
    Ueda, Akihiko
    Kuroda, Yutaka
    Kawai, Toshiyuki
    Okuzu, Yaichiro
    Okuno, Yasushi
    Matsuda, Shuichi
    JOURNAL OF ARTHROPLASTY, 2025, 40 (01) : 136 - 143.e1
  • [38] Accuracy of Personalized Computed Tomographic 3D Templating for Acetabular Cup Placement in Revision Arthroplasty
    Winter, Philipp
    Fritsch, Ekkehard
    Tschernig, Thomas
    Goebel, Lars
    Wolf, Milan
    Mueller, Manuel
    Weise, Julius J.
    Orth, Patrick
    Landgraeber, Stefan
    MEDICINA-LITHUANIA, 2023, 59 (09):
  • [39] CLINICAL USE OF 3-D IMAGE REGISTRATION
    Remeijer, Peter
    RADIOTHERAPY AND BRACHYTHERAPY, 2009, : 127 - +
  • [40] Fast and Robust 3D to 2D Image Registration by Backprojection of Gradient Covariances
    Spiclin, Ziga
    Likar, Bostjan
    Pernus, Franjo
    BIOMEDICAL IMAGE REGISTRATION (WBIR 2014), 2014, 8545 : 124 - 133