Computer assisted determination of acetabular cup orientation using 2D-3D image registration

被引:7
|
作者
Zheng, Guoyan [1 ]
Zhang, Xuan [1 ]
机构
[1] Univ Bern, Inst Surg Technol & Biomech, CH-3014 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
Post-operative cup orientation; X-ray radiograph; 2D-3D registration; Total hip arthroplasty; Pelvic tilt; TOTAL HIP-ARTHROPLASTY; CT; ANTEVERSION; PLACEMENT; COMPONENT; TILT; THA;
D O I
10.1007/s11548-010-0407-x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background 2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations. Methods A new formulation for determination of postoperative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips. Results Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 +/- 0.7 degrees (range from 0.1 degrees to 2.0 degrees.) for inclination and 1.7 +/- 1.2 degrees (range from 0.0 degrees to 3.9 degrees) for anteversion, taking the measurements from postoperative CT images as ground truths. Conclusions Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of postoperative cup orientation and measurement of pelvic tilt and rotation.
引用
收藏
页码:437 / 447
页数:11
相关论文
共 50 条
  • [21] 2D-3D registration for 3D analysis of lower limb alignment in a weight-bearing condition
    Shim, Eungjune
    Kim, Youngjun
    Lee, Deukhee
    Lee, Byung Hoon
    Woo, Sungkyung
    Lee, Kunwoo
    APPLIED MATHEMATICS-A JOURNAL OF CHINESE UNIVERSITIES SERIES B, 2018, 33 (01) : 59 - 70
  • [22] 2D-3D registration for prostate radiation therapy based on a statistical model of transmission images
    Munbodh, Reshma
    Tagare, Hemant D.
    Chen, Zhe
    Jaffray, David A.
    Moseley, Douglas J.
    Knisely, Jonathan P. S.
    Duncan, James S.
    MEDICAL PHYSICS, 2009, 36 (10) : 4555 - 4568
  • [23] 2D-3D registration for brain radiation therapy using a 3D CBCT and a single limited field-of-view 2D kV radiograph
    Munbodh, R.
    Moseley, D. J.
    XVII INTERNATIONAL CONFERENCE ON THE USE OF COMPUTERS IN RADIATION THERAPY (ICCR 2013), 2014, 489
  • [24] 2D-3D registration for 3D analysis of lower limb alignment in a weight-bearing condition
    SHIM Eungjune
    KIM Youngjun
    LEE Deukhee
    LEE Byung Hoon
    WOO Sungkyung
    LEE Kunwoo
    Applied Mathematics:A Journal of Chinese Universities, 2018, 33 (01) : 59 - 70
  • [25] Single Shot 2D3D Image Registration
    Xie, Yi
    Meng, Cai
    Guan, ShaoYa
    Wang, Qi
    2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [26] The Accuracy of Acetabular Cup Positioning Using Patient-Specific 3D Orientation Guidance in Total Hip Arthroplasty
    McMahon, Stephen J.
    Christmas, Maxim U. S., I
    McMahon, Jack
    Pierrepont, Jim
    McMahon, Ryan
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36
  • [27] Incorporating spatial information into 3D-2D image registration
    Zheng, Guoyan
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, PROCEEDINGS, 2007, 4673 : 792 - 800
  • [28] Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: A cadaver study
    Lin, Fang
    Lim, Dohyung
    Wixson, Richard L.
    Milos, Steven
    Hendrix, Ronald W.
    Makhsous, Mohsen
    CLINICAL BIOMECHANICS, 2008, 23 (08) : 1004 - 1011
  • [29] Fast 2D-3D marker-based registration of CT and X-ray fluoroscopy images for image-guided surgery
    Hong, Helen
    Kim, Kyehyun
    Park, Sungjin
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [30] Statistically Deformable 2D/3D Registration for Estimating Post-operative Cup Orientation from a Single Standard AP X-ray Radiograph
    Guoyan Zheng
    Annals of Biomedical Engineering, 2010, 38 : 2910 - 2927