Variability of Multiangle Isometric Force-Time Characteristics in Trained Men

被引:10
|
作者
Oranchuk, Dustin J. [1 ]
Storey, Adam G. [1 ]
Nelson, Andre R. [2 ]
Neville, Jonathon G. [1 ]
Cronin, John B. [1 ]
机构
[1] Auckland Univ Technol, Sports Performance Res Inst New Zealand, Auckland, New Zealand
[2] Victoria Univ, Inst Hlth & Sport, Melbourne, Vic, Australia
关键词
impulse; optimal-angle; rate of force development; reliability; isokinetic; torque; SPORTS-MEDICINE; RELIABILITY; ANGLE;
D O I
10.1519/JSC.0000000000003405
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Oranchuk, DJ, Storey, AG, Nelson, AR, Neville, JG, and Cronin, JB. Variability of multiangle isometric force-time characteristics in trained men. J Strength Cond Res 36(1): 284-288, 2022-Measurements of isometric force, rate of force development (RFD), and impulse are widely reported. However, little is known about the variability and reliability of these measurements at multiple angles, over repeated testing occasions in a homogenous, resistance-trained population. Thus, understanding the intersession variability of multiangle isometric force-time characteristics provides the purpose of this article. Three sessions of isometric knee extensions at 40 degrees, 70 degrees, and 100 degrees of flexion were performed by 26 subjects across 51 limbs. All assessments were repeated on 3 occasions separated by 5-8 days. Variability was qualified by doubling the typical error of measurement (TEM), with thresholds of 0.2-0.6 (small), 0.6-1.2 (moderate), 1.2-2.0 (large), 2.0-4.0 (very large), and >4.0 (extremely large). In addition, variability was deemed large when the intraclass correlation coefficient (ICC) was <0.67 and coefficient of variation (CV) >10%; moderate when ICC >0.67 or CV <10% (but not both); and small when both ICC >0.67 and CV <10%. Small to moderate between-session variability (ICC = 0.68-0.95, CV = 5.2-18.7%, TEM = 0.24-0.49) was associated with isometric peak force, regardless of angle. Moderate to large variability was seen in early-stage (0-50 ms) RFD and impulse (ICC = 0.60-0.80, CV = 22.4-63.1%, TEM = 0.62-0.74). Impulse and RFD at 0-100 ms, 0-200 ms, and 100-200 ms were moderately variable (ICC = 0.71-0.89, CV = 11.8-42.1%, TEM = 0.38-0.60) at all joint angles. Isometric peak force and late-stage isometric RFD and impulse measurements were found to have low intersession variability regardless of joint angle. However, practitioners need to exercise caution when making inferences about early-stage RFD and impulse measures due to moderate-large variability.
引用
收藏
页码:284 / 288
页数:5
相关论文
共 50 条
  • [21] A comparison of manual and automatic force-onset identification methodologies and their effect on force-time characteristics in the isometric midthigh pull
    Guppy, Stuart N.
    Brady, Claire J.
    Kotani, Yosuke
    Connolly, Shannon
    Comfort, Paul
    Lake, Jason P.
    Haff, G. Gregory
    SPORTS BIOMECHANICS, 2024, 23 (10) : 1726 - 1737
  • [22] Relationship between isometric force-time characteristics and dynamic performance pre- and post-training
    Lum, Danny
    Joseph, Ranald
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2020, 60 (04): : 520 - 526
  • [23] Variability and repeatability of spinal manipulation force-time characteristics in thoracic spinal manipulation on a manikin
    Nyiro, Luana
    Gorrell, Lindsay M.
    Cecchini, Valentina
    Menon, Carlo
    Elgendi, Mohamed
    Schweinhardt, Petra
    CHIROPRACTIC & MANUAL THERAPIES, 2024, 32 (01)
  • [24] EFFECTS OF FATIGUE AND RECOVERY ON ELECTROMYOGRAPHIC AND ISOMETRIC FORCE-TIME AND RELAXATION-TIME CHARACTERISTICS OF HUMAN SKELETAL-MUSCLE
    HAKKINEN, K
    KOMI, PV
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1986, 55 (06): : 588 - 596
  • [25] Agreement in Squat Jump Force-Time Characteristics Between Smith Machine and Free-Weight Squat Jump Force-Time Characteristics
    Kotani, Yosuke
    Lake, Jason
    Guppy, Stuart N.
    Poon, Wayne
    Nosaka, Kazunori
    Haff, G. Gregory
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2023, 37 (10) : 1955 - 1962
  • [26] RELATIONSHIPS BETWEEN FORCE-TIME CHARACTERISTICS OF THE ISOMETRIC MIDTHIGH PULL AND DYNAMIC PERFORMANCE IN PROFESSIONAL RUGBY LEAGUE PLAYERS
    West, Daniel J.
    Owen, Nick J.
    Jones, Marc R.
    Bracken, Richard M.
    Cook, Christian J.
    Cunningham, Dan J.
    Shearer, David A.
    Finn, Charlotte V.
    Newton, Robert U.
    Crewther, Blair T.
    Kilduff, Liam P.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (11) : 3070 - 3075
  • [27] COMPARISON OF THE HANG HIGH PULL AND LOADED JUMP SQUAT FOR THE DEVELOPMENT OF VERTICAL JUMP AND ISOMETRIC FORCE-TIME CHARACTERISTICS
    Oranchuk, Dustin J.
    Robinson, Tracey L.
    Switaj, Zachary J.
    Drinkwater, Eric J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2019, 33 (01) : 17 - 24
  • [28] Recovery of Force-Time Characteristics After Australian Rules Football Matches: Examining the Utility of the Isometric Midthigh Pull
    Norris, Dean
    Joyce, David
    Siegler, Jason
    Clock, James
    Lovell, Ric
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2019, 14 (06) : 765 - 770
  • [29] The Inter-Session Reliability of Isometric Force-Time Variables and the Effects of Filtering and Starting Force
    Moir, Gavin L.
    Getz, Aaron
    Davis, Shala E.
    Marques, Mario
    Witmer, Chad A.
    JOURNAL OF HUMAN KINETICS, 2019, 66 (01) : 43 - 55
  • [30] EFFECT OF DIFFERENT ONSET THRESHOLDS ON ISOMETRIC MIDTHIGH PULL FORCE-TIME VARIABLES
    Dos'Santos, Thomas
    Jones, Paul A.
    Comfort, Paul
    Thomas, Christopher
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (12) : 3463 - 3473