Apparatus for X-ray diffraction microscopy and tomography of cryo specimens

被引:22
作者
Beetz, T [1 ]
Howells, MR
Jacobsen, C
Kao, CC
Kirz, J
Lima, E
Mentes, TO
Miao, H
Sanchez-Hanke, C
Sayre, D
Shapiro, D
机构
[1] Brookhaven Natl Lab, Ctr Funct Nanomat, Upton, NY 11973 USA
[2] SUNY Stony Brook, Dept Phys & Astron, Stony Brook, NY 11794 USA
[3] Lawrence Berkeley Natl Lab, Adv Light Source, Berkeley, CA 94720 USA
[4] Brookhaven Natl Lab, Natl Synchrotron Light Source, Upton, NY 11973 USA
[5] INFM, TASC, Natl Lab, I-34012 Trieste, Italy
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
X-ray microscopy; X-ray imaging; X-ray tomography; diffraction microscopy; lensless imaging;
D O I
10.1016/j.nima.2004.12.040
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An apparatus for diffraction microscopy of biological and materials science specimens is described. In this system, a coherent soft X-ray beam is selected with a pinhole, and the illuminated specimen is followed by an adjustable beamstop and CCD camera to record diffraction data from non-crystalline specimens. In addition, a Fresnel zone plate can be inserted to allow for direct imaging. The system makes use of a cryogenic specimen holder with cryotransfer capabilities to allow frozen hydrated specimens to be loaded. The specimen can be tilted over a range of +/- 80 degrees for three-dimensional imaging; this is done by computer-controlled motors, enabling automated alignment of the specimen through a tilt series. The system is now in use for experiments in soft X-ray diffraction microscopy. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:459 / 468
页数:10
相关论文
共 22 条
[1]  
BEETZ T, 2004, THESIS STONY BROOK U
[2]  
CHAPMAN HN, UNPUB HIGH RESOLUTIO
[3]   Phase retrieval by iterated projections [J].
Elser, V .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (01) :40-55
[4]   PHASE RETRIEVAL ALGORITHMS - A COMPARISON [J].
FIENUP, JR .
APPLIED OPTICS, 1982, 21 (15) :2758-2769
[5]  
GERCHBERG RW, 1972, OPTIK, V35, P237
[6]   RADIATION-DAMAGE RELATIVE TO TRANSMISSION ELECTRON-MICROSCOPY OF BIOLOGICAL SPECIMENS AT LOW-TEMPERATURE - REVIEW [J].
GLAESER, RM ;
TAYLOR, KA .
JOURNAL OF MICROSCOPY, 1978, 112 (JAN) :127-138
[7]  
Goedgebuer J. P., 1980, SPRINGER LECT NOTES, V112, P229
[8]  
HOWELLS M, IN PRESS J ELECT SPE
[9]   An off-axis zone-plate monochromator for high-power undulator radiation [J].
Howells, MR ;
Charalambous, P ;
He, H ;
Marcesini, S ;
Spence, JCH .
DESIGN AND MICROFABRICATION OF NOVEL X-RAY OPTICS, 2002, 4783 :65-73
[10]   RESOLUTION IN SOFT-X-RAY MICROSCOPES [J].
JACOBSEN, C ;
KIRZ, J ;
WILLIAMS, S .
ULTRAMICROSCOPY, 1992, 47 (1-3) :55-79