Provisional crown and fixed partial denture materials:: Mechanical properties and degree of conversion

被引:46
作者
Balkenhol, Markus [1 ]
Feryer, Paul [1 ]
Mautner, Meike Christina [2 ]
Woestmann, Bernd [1 ]
机构
[1] Univ Giessen, Dept Prosthet Dent, D-35392 Giessen, Germany
[2] Private Practice, D-63667 Nidda, Germany
关键词
temporary c&b materials; provisionals; degree of conversion; FTIR analysis; flexural strength; flexural modulus; regression analysis; in vitro test; thermocycling; resin;
D O I
10.1016/j.dental.2007.06.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. This study aimed to investigate the flexural strength (FS) and flexural modulus (FM) of temporary crown and bridge materials (t-c&b) at different storage times and to identify possible correlations between the mechanical properties and the degree of conversion (DC). Methods. FS and FM of four proprietary di-methacrylate-based t-c&bs were tested in a 3-point bending test according to EN ISO 4049:2000 at various storage times after mixing (37 degrees C dry/water) including thermocycling (5000x, 5-55 degrees C). DC was determined by calculating the percentage of reacted C = C double bonds using FTIR analysis (baseline method). Mean values of all measurements were calculated and subjected to the Games-Howell test for statistical analysis (p = 0.05) as well as a logarithmic regression analysis. Results. FS and FM were very low 10 min after mixing for all materials tested (FS: 14.5-24.5 MPa; FM: 96.1-211.2 MPa). A very high correlation was observed between FS and FM on the one hand and storage time on the other. The DC was on a high level already 10 min after mixing (57.7-69.8%) for all materials except for Structur Premium (42.2%). Structur Premium showed a significantly higher FS and FM (p < 0.05) compared to all other materials tested though a significantly lower DC (p < 0.05). Significance. FS and FM of t-c&bs significantly depend on the time after mixing. Dentists should be aware of the fact that the mechanical stability of temporary crowns is comparably low in the first hours after fabrication. The DC does not allow drawing conclusions about the mechanical stability of a t-c&b. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1574 / 1583
页数:10
相关论文
共 33 条
[1]   Photopolymerization kinetics of multifunctional monomers [J].
Andrzejewska, E .
PROGRESS IN POLYMER SCIENCE, 2001, 26 (04) :605-665
[2]  
[Anonymous], 1997, FUNDAMENTALS FIXED P
[3]  
[Anonymous], 2006, CRAIGS RESTORATIVE D
[4]  
ANUSAVIC KJ, 2003, PHILLIPS SCI DENTAL
[5]  
ASMUSSEN E, 1982, SCAND J DENT RES, V90, P490
[6]   A new kinetic model for the photopolymerization shrinkage-strain of dental composites and resin-monomers [J].
Atai, Mohammad ;
Watts, Dauid C. .
DENTAL MATERIALS, 2006, 22 (08) :785-791
[7]   A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: Report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics [J].
Burns, DR ;
Beck, DA ;
Nelson, SK .
JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (05) :474-497
[8]   CORRELATION BETWEEN DEGREE OF CONVERSION, FILLER CONCENTRATION AND MECHANICAL-PROPERTIES OF POSTERIOR COMPOSITE RESINS [J].
CHUNG, KH ;
GREENER, EH .
JOURNAL OF ORAL REHABILITATION, 1990, 17 (05) :487-494
[9]  
Coates J., 2000, ENCY ANAL CHEM, P10815, DOI DOI 10.1002/9780470027318.A5606
[10]  
Dietz JE, 1997, POLYMER, V38, P3767