Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung

被引:59
作者
Sartoretti, Thomas [1 ]
Racine, Damien [2 ]
Mergen, Victor [1 ]
Jungblut, Lisa [1 ]
Monnin, Pascal [2 ]
Flohr, Thomas G. [3 ]
Martini, Katharina [1 ]
Frauenfelder, Thomas [1 ]
Alkadhi, Hatem [1 ]
Euler, Andre [1 ]
机构
[1] Univ Zurich, Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, CH-8091 Zurich, Switzerland
[2] Univ Lausanne UNIL, Lausanne Univ Hosp CHUV, Inst Radiat Phys IRA, CH-1010 Lausanne, Switzerland
[3] Siemens Healthcare GmbH, D-91052 Forchheim, Germany
关键词
phantoms; imaging; tomography; X-ray computed; lung; COMPUTED-TOMOGRAPHY; ABDOMINAL CT; IMAGE QUALITY; CHEST; FILTER; NOISE;
D O I
10.3390/diagnostics12020522
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to characterize image quality and to determine the optimal strength levels of a novel iterative reconstruction algorithm (quantum iterative reconstruction, QIR) for low-dose, ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) of the lung. Images were acquired on a clinical dual-source PCD-CT in the UHR mode and reconstructed with a sharp lung reconstruction kernel at different strength levels of QIR (QIR-1 to QIR-4) and without QIR (QIR-off). Noise power spectrum (NPS) and target transfer function (TTF) were analyzed in a cylindrical phantom. 52 consecutive patients referred for low-dose UHR chest PCD-CT were included (CTDIvol: 1 +/- 0.6 mGy). Quantitative image quality analysis was performed computationally which included the calculation of the global noise index (GNI) and the global signal-to-noise ratio index (GSNRI). The mean attenuation of the lung parenchyma was measured. Two readers graded images qualitatively in terms of overall image quality, image sharpness, and subjective image noise using 5-point Likert scales. In the phantom, an increase in the QIR level slightly decreased spatial resolution and considerably decreased noise amplitude without affecting the frequency content. In patients, GNI decreased from QIR-off (202 +/- 34 HU) to QIR-4 (106 +/- 18 HU) (p < 0.001) by 48%. GSNRI increased from QIR-off (4.4 +/- 0.8) to QIR-4 (8.2 +/- 1.6) (p < 0.001) by 87%. Attenuation of lung parenchyma was highly comparable among reconstructions (QIR-off: -849 +/- 53 HU to QIR-4: -853 +/- 52 HU, p < 0.001). Subjective noise was best in QIR-4 (p < 0.001), while QIR-3 was best for sharpness and overall image quality (p < 0.001). Thus, our phantom and patient study indicates that QIR-3 provides the optimal iterative reconstruction level for low-dose, UHR PCD-CT of the lungs.
引用
收藏
页数:13
相关论文
共 43 条
[1]  
[Anonymous], 2012, J ICRU, DOI DOI 10.1093/JICRU/NDT007
[2]   High-Resolution Chest Computed Tomography Imaging of the Lungs Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography [J].
Bartlett, David J. ;
Koo, Chi Wan ;
Bartholmai, Brian J. ;
Rajendran, Kishore ;
Weaver, Jayse M. ;
Halaweish, Ahmed E. ;
Leng, Shuai ;
McCollough, Cynthia H. ;
Fletcher, Joel G. .
INVESTIGATIVE RADIOLOGY, 2019, 54 (03) :129-137
[3]   Low-dose CT of the lung: potential value of iterative reconstructions [J].
Baumueller, Stephan ;
Winklehner, Anna ;
Karlo, Christoph ;
Goetti, Robert ;
Flohr, Thomas ;
Russi, Erich W. ;
Frauenfelder, Thomas ;
Alkadhi, Hatem .
EUROPEAN RADIOLOGY, 2012, 22 (12) :2597-2606
[4]   Automated Technique to Measure Noise in Clinical CT Examinations [J].
Christianson, Olav ;
Winslow, James ;
Frush, Donald P. ;
Samei, Ehsan .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (01) :W93-W99
[5]   Analysis of Computed Tomography Radiation Doses Used for Lung Cancer Screening Scans [J].
Demb, Joshua ;
Chu, Philip ;
Yu, Sophronia ;
Whitebird, Robin ;
Solberg, Leif ;
Miglioretti, Diana L. ;
Smith-Bindman, Rebecca .
JAMA INTERNAL MEDICINE, 2019, 179 (12) :1650-1657
[6]   Coronary Calcium Scoring with First Generation Dual-Source Photon-Counting CT-First Evidence from Phantom and In-Vivo Scans [J].
Eberhard, Matthias ;
Mergen, Victor ;
Higashigaito, Kai ;
Allmendinger, Thomas ;
Manka, Robert ;
Flohr, Thomas ;
Schmidt, Bernhard ;
Euler, Andre ;
Alkadhi, Hatem .
DIAGNOSTICS, 2021, 11 (09)
[7]   High-Pitch Photon-Counting Detector Computed Tomography Angiography of the Aorta Intraindividual Comparison to Energy-Integrating Detector Computed Tomography at Equal Radiation Dose [J].
Euler, Andre ;
Higashigaito, Kai ;
Mergen, Victor ;
Sartoretti, Thomas ;
Zanini, Bettina ;
Schmidt, Bernhard ;
Flohr, Thomas G. ;
Ulzheimer, Stefan ;
Eberhard, Matthias ;
Alkadhi, Hatem .
INVESTIGATIVE RADIOLOGY, 2022, 57 (02) :115-121
[8]   Unenhanced third-generation dual-source chest CT using a tin filter for spectral shaping at 100 kVp [J].
Haubenreisser, Holger ;
Meyer, Mathias ;
Sudarski, Sonja ;
Allmendinger, Thomas ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) :1608-1613
[9]   Contrast-Enhanced Abdominal CT with Clinical Photon-Counting Detector CT: Assessment of Image Quality and Comparison with Energy-Integrating Detector CT [J].
Higashigaito, Kai ;
Euler, Andre ;
Eberhard, Matthias ;
Flohr, Thomas G. ;
Schmidt, Bernhard ;
Alkadhi, Hatem .
ACADEMIC RADIOLOGY, 2022, 29 (05) :689-697
[10]   A phantom study investigating the relationship between ground-glass opacity visibility and physical detectability index in low-dose chest computed tomography [J].
Ichikawa, Katsuhiro ;
Kobayashi, Takeshi ;
Sagawa, Motoyasu ;
Katagiri, Ayako ;
Uno, Yukiko ;
Nishioka, Ryo ;
Matsuyama, Jun .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04) :202-215