Evaluation of the first seven years operating data of a RO brackish water desalination plant in Las Palmas, Canary Islands, Spain

被引:10
作者
Ruiz-Garcia, Alejandro [1 ]
Ruiz-Saavedra, Enrique [2 ]
Perez Baez, Sebastian O. [3 ]
机构
[1] Univ Las Palmas Gran Canaria, Escuela Ingn Ind & Civiles, Dept Ingn Civil, Las Palmas Gran Canaria 35017, Spain
[2] Univ Las Palmas Gran Canaria, Escuela Ingn Ind & Civiles, Dept Cartog & Expres Grafica Ingn, Las Palmas Gran Canaria 35017, Spain
[3] Univ Las Palmas Gran Canaria, Escuela Ingn Ind & Civiles, Dept Ingn Proc, Las Palmas Gran Canaria 35017, Spain
关键词
Brackish water; Operating data; Desalination plants; Normalization; Reverse osmosis;
D O I
10.1080/19443994.2014.908145
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The present research describes the graphical evolution of the operating information of the first seven years. A study of the normalization and standardization of the information about the seven years of evolution of the plant for fixed feedwater conditions, operating pressure, and system recovery are also shown, so that the performance evaluation of the plan can be indicated correctly. From these results, it has been deduced that the compaction and fouling factor values and the average ionic permeability coefficients of the reverse osmosis (RO) membrane were utilized. Likewise, this paper describes the graphic evolution of the brine Langelier saturation index and Stiff and Davis stability index (actual and theoric values). The conclusions of this work and the operating experience are intended to get a practical and optimum design of RO brackish water desalination plants without using acid in the pretreatment and having a reasonable operating life between 7 and 8 years.
引用
收藏
页码:3193 / 3199
页数:7
相关论文
共 11 条
  • [1] [Anonymous], GEN PROC MEMBR CLEAN
  • [2] [Anonymous], FILMT MEMBR TECHN MA
  • [3] [Anonymous], VIT 3000
  • [4] [Anonymous], TECHN INF GUID SEL A
  • [5] [Anonymous], FILMT MEMBR PROD INF
  • [6] ASTM, 2004, D451600 ASTM
  • [7] ASTM, 2004, D373994 ASTM
  • [8] ASTM, 2004, D458291 ASTM
  • [9] Evaluation of the five years operating data of a RO brackish water desalination plant in Las Palmas, Canary Islands, Spain: a historic case
    Ruiz Saavedra, Enrique
    Gomez Gotor, Antonio
    Perez Baez, Sebastian O.
    Ramos Martin, Alejandro
    Ruiz-Garcia, A.
    Casanas Gonzalez, Antonio
    [J]. DESALINATION AND WATER TREATMENT, 2013, 51 (25-27) : 4785 - 4789
  • [10] Estimation of the maximum conversion level in reverse osmosis brackish water desalination plants
    Ruiz Saavedra, Enrique
    Gomez Gotor, Antonio
    Perez Baez, Sebastian O.
    Ramos Martin, Alejandro
    [J]. DESALINATION AND WATER TREATMENT, 2013, 51 (4-6) : 1143 - 1150