Automated Segmentation of Left Ventricular Myocardium on Cardiac Computed Tomography Using Deep Learning

被引:22
作者
Koo, Hyun Jung [1 ,2 ]
Lee, June-Goo [3 ]
Ko, Ji Yeon [3 ]
Lee, Gaeun [3 ]
Kang, Joon-Won [1 ,2 ]
Kim, Young-Hak [4 ]
Yang, Dong Hyun [1 ,2 ]
机构
[1] Univ Ulsan, Dept Radiol, Asan Med Ctr, Coll Med, Seoul, South Korea
[2] Univ Ulsan, Res Inst Radiol, Asan Med Ctr, Coll Med, Seoul, South Korea
[3] Univ Ulsan, Asan Inst Life Sci, Asan Med Ctr, Biomed Engn Res Ctr,Coll Med, Seoul, South Korea
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Div Cardiol,Internal Med, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
Segmentation; Left ventricle; Deep learning; Machine learning; Computed tomography; END-SYSTOLIC VOLUME; CT; ECHOCARDIOGRAPHY; ANGIOGRAPHY; HEART; SOFTWARE; SURVIVAL; MODEL;
D O I
10.3348/kjr.2019.0378
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the accuracy of a deep learning-based automated segmentation of the left ventricle (LV) myocardium using cardiac CT. Materials and Methods: To develop a fully automated algorithm, 100 subjects with coronary artery disease were randomly selected as a development set (50 training / 20 validation / 30 internal test). An experienced cardiac radiologist generated the manual segmentation of the development set. The trained model was evaluated using 1000 validation set generated by an experienced technician. Visual assessment was performed to compare the manual and automatic segmentations. In a quantitative analysis, sensitivity and specificity were calculated according to the number of pixels where two three-dimensional masks of the manual and deep learning segmentations overlapped. Similarity indices, such as the Dice similarity coefficient (DSC), were used to evaluate the margin of each segmented masks. Results: The sensitivity and specificity of automated segmentation for each segment (1-16 segments) were high (85.5-100.0%). The DSC was 88.3 +/- 6.2%. Among randomly selected 100 cases, all manual segmentation and deep learning masks for visual analysis were classified as very accurate to mostly accurate and there were no inaccurate cases (manual vs. deep learning: very accurate, 31 vs. 53; accurate, 64 vs. 39; mostly accurate, 15 vs. 8). The number of very accurate cases for deep learning masks was greater than that for manually segmented masks. Conclusion: We present deep learning-based automatic segmentation of the LV myocardium and the results are comparable to manual segmentation data with high sensitivity, specificity, and high similarity scores.
引用
收藏
页码:660 / 669
页数:10
相关论文
共 30 条
[1]   Feasibility of automatic assessment of four-chamber cardiac function with MDCT: Initial clinical application and validation [J].
Abadi, Sobhi ;
Roguin, Ariel ;
Engel, Ahuva ;
Lessick, Jonathan .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (01) :175-181
[2]   Computer-Based Automated Left Atrium Segmentation and Volumetry from ECG-Gated Coronary CT Angiography Data: Comparison with Manual Slice Segmentation and Ultrasound Planimetric Methods [J].
Bauer, R. W. ;
Kraus, B. ;
Bernhardt, D. ;
Kerl, J. M. ;
Lehnert, T. ;
Ackermann, H. ;
Vega-Higuera, F. ;
Vogl, T. J. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2010, 182 (12) :1110-1117
[3]   Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography - Comparison with cine magnetic resonance imaging [J].
Belge, Benedicte ;
Coche, Emmanuel ;
Pasquet, Agnes ;
Vanoverschelde, Jean-Louis J. ;
Gerber, Bernhard L. .
EUROPEAN RADIOLOGY, 2006, 16 (07) :1424-1433
[4]   Quantitative right and left ventricular functional analysis during gated whole-chest MDCT: A feasibility study comparing automatic segmentation to semi-manual contouring [J].
Coche, Emmanuel ;
Walker, Matthew J. ;
Zech, Francis ;
de Crombrugghe, Rodolphe ;
Vlassenbroek, Alain .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 74 (03) :E139-E144
[5]   Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography [J].
Dirksen, MS ;
Bax, JJ ;
de Roos, A ;
Jukema, JW ;
van der Geest, RJ ;
Geleijns, K ;
Boersma, E ;
van der Wall, EE ;
Lamb, HJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2002, 90 (10) :1157-+
[6]   Segmentation of the heart and great vessels in CT images using a model-based adaptation framework [J].
Ecabert, Olivier ;
Peters, Jochen ;
Walker, Matthew J. ;
Ivanc, Thomas ;
Lorenz, Cristian ;
von Berg, Jens ;
Lessick, Jonathan ;
Vembar, Mani ;
Weese, Juergen .
MEDICAL IMAGE ANALYSIS, 2011, 15 (06) :863-876
[7]  
Emad O, 2015, IEEE ENG MED BIO, P683, DOI 10.1109/EMBC.2015.7318454
[8]   Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging [J].
Fischbach, Roman ;
Juergens, Kai Uwe ;
Ozgun, Murat ;
Maintz, David ;
Grude, Matthias ;
Seifarth, Harald ;
Heindel, Walter ;
Wichter, Thomas .
EUROPEAN RADIOLOGY, 2007, 17 (04) :1009-1017
[9]   Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography - Comparison with magnetic resonance imaging [J].
Grude, M ;
Juergens, KU ;
Wichter, T ;
Paul, M ;
Fallenberg, EM ;
Muller, JG ;
Heindel, W ;
Breithardt, G ;
Fischbach, R .
INVESTIGATIVE RADIOLOGY, 2003, 38 (10) :653-661
[10]   END-SYSTOLIC VOLUME AND LONG-TERM SURVIVAL AFTER CORONARY-ARTERY BYPASS GRAFT-SURGERY IN PATIENTS WITH IMPAIRED LEFT-VENTRICULAR FUNCTION [J].
HAMER, AW ;
TAKAYAMA, M ;
ABRAHAM, KA ;
ROCHE, AHG ;
KERR, AR ;
WILLIAMS, BF ;
RAMAGE, MC ;
WHITE, HD .
CIRCULATION, 1994, 90 (06) :2899-2904