A Comparative Analysis of the Piezoelectric Ultrasonic Appliance and Trephine Bur for Apical Location: An In Vitro Study

被引:3
作者
Caceres Madrono, Esther [1 ]
Rodriguez Torres, Paulina [1 ]
Oussama, Soraya [1 ]
Zubizarreta-Macho, Alvaro [1 ,2 ]
Bufala Perez, Maria [1 ]
Mena-Alvarez, Jesus [3 ]
Riad Deglow, Elena [1 ]
Hernandez Montero, Sofia [1 ]
机构
[1] Alfonso X Sabio Univ, Fac Hlth Sci, Dept Implant Surg, Madrid 28691, Spain
[2] Univ Salamanca, Fac Med & Dent, Dept Surg, Salamanca 37008, Spain
[3] Alfonso X Sabio Univ, Fac Hlth Sci, Dept Endodont, Madrid 28691, Spain
来源
JOURNAL OF PERSONALIZED MEDICINE | 2021年 / 11卷 / 10期
关键词
apical location; apicoectomy; cone-beam computed tomography scan; piezoelectric; trephine bur; ENDODONTIC MICROSURGERY; ACCURACY; SURGERY; TISSUE;
D O I
10.3390/jpm11101034
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
To compare and contrast the accuracy of piezoelectric ultrasonic insert (PUI) and trephine bur (TB) osteotomy site preparation techniques for apical location. (1) Material and methods: A total of 138 osteotomy site preparations were randomly distributed into one of two study groups. Group A: TB technique (n = 69) and B: PUI technique (n = 69). A preoperative cone-beam computed tomography scan and an intraoral scan were performed and uploaded to implant-planning software to plan the virtual osteotomy site preparations for apical location. Subsequently, the osteotomy site preparations were performed in the experimental models with both osteotomy site preparation techniques and a postoperative CBCT scan was performed and uploaded into the implant-planning software and matched with the virtually planned osteotomy site preparations to measure the deviation angle and horizontal deviation as captured at the coronal entry point and apical end-point between osteotomy site preparations using Student's t-test statistical analysis. (2) Results: The paired t-test found statistically significant differences at the coronal entry-point deviations (p = 0.0104) and apical end-point deviations (p = 0.0104) between the TB and PUI study groups; however, no statistically significant differences were found in the angular deviations (p = 0.309) between the trephine bur and piezoelectric ultrasonic insert study groups. (3) Conclusions: The results showed that the TB is more accurate than the PUI for apical location.</p>
引用
收藏
页数:9
相关论文
共 30 条
  • [1] Safety and Effects of the Rapid Maxillary Expander on Temporomandibular Joint in Subjects Affected by Juvenile Idiopathic Arthritis: A Retrospective Study
    Abate, Andrea
    Cavagnetto, Davide
    Rusconi, Francesca Maria Emilia
    Cressoni, Paolo
    Esposito, Luca
    [J]. CHILDREN-BASEL, 2021, 8 (01):
  • [2] Digitally planned root end surgery with static guide and custom trephine burs: A case report
    Antal, Mark
    Nagy, Eszter
    Sanyo, Lajos
    Braunitzer, Gabor
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2020, 16 (04)
  • [3] Implant Placement Accuracy Using Dynamic Navigation
    Block, Michael S.
    Emery, Robert W.
    Lank, Kathryn
    Ryan, James
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 92 - 99
  • [4] Endodontic surgery
    Chong, B. S.
    Rhodes, J. S.
    [J]. BRITISH DENTAL JOURNAL, 2014, 216 (06) : 281 - 290
  • [5] Treatment outcome in endodontics: The Toronto Study-Phase 4: Initial treatment
    de Chevigny, Cristian
    Dao, Thuan T.
    Basrani, Bettina R.
    Marquis, Vincent
    Farzaneh, Mahsa
    Abitbol, Sarah
    Friedman, Sbimon
    [J]. JOURNAL OF ENDODONTICS, 2008, 34 (03) : 258 - 263
  • [6] Endodontic Microsurgery Using Dynamic Navigation System: A Case Report
    Gambarini, Gianluca
    Galli, Massimo
    Stefanelli, Luigi, V
    Di Nardo, Dario
    Morese, Antonio
    Seracchiani, Marco
    De Angelis, Francesca
    Di Carlo, Stefano
    Testarelli, Luca
    [J]. JOURNAL OF ENDODONTICS, 2019, 45 (11) : 1397 - 1402
  • [7] Targeted Endodontic Microsurgery: A Novel Approach to Anatomically Challenging Scenarios Using 3-dimensional-printed Guides and Trephine Burs-A Report of 3 Cases
    Giacomino, C. Michelle
    Ray, Jarom J.
    Wealleans, James A.
    [J]. JOURNAL OF ENDODONTICS, 2018, 44 (04) : 671 - 677
  • [8] 3-Dimensional Accuracy of Dynamic Navigation Technology in Locating Calcified Canals
    Jain, Sameer D.
    Carrico, Caroline K.
    Bermanis, Ido
    [J]. JOURNAL OF ENDODONTICS, 2020, 46 (06) : 839 - 845
  • [9] The accuracy of static vs. dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial
    Kaewsiri, Dechawat
    Panmekiate, Soontra
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (06) : 505 - 514
  • [10] Outcome of nonsurgical retreatment and endodontic microsurgery: a meta-analysis
    Kang, Minji
    Jung, Hoi In
    Song, Minju
    Kim, Sue Youn
    Kim, Hyeon-Cheol
    Kim, Euiseong
    [J]. CLINICAL ORAL INVESTIGATIONS, 2015, 19 (03) : 569 - 582