Fast sequential injection determination of benzo[A]pyrene using variable angle fluorescence with on-line solid-phase extraction

被引:38
作者
Erustes, JA
Andrade-Eiroa, A
Cladera, A
Forteza, R
Cerdà, V
机构
[1] Univ Balearic Isl, Dept Chem, E-07071 Palma de Mallorca, Spain
[2] Univ A Coruna, Dept Analyt Chem, E-15071 La Coruna, Spain
关键词
D O I
10.1039/b010129j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A methodology for the analysis of drinking water for one of the most potent carcinogenic agents known; benzo[a]pyrene (BaP), in the presence of other interfering PAHs is presented. The methodology described is based on the sequential injection analysis of the sample on to a microcolumn (containing 5 mg of C-18) where extraction and preconcentration of BaP takes place, followed by elution of BaP with 1 ml of 1,4-dioxane and subsequent detection by using variable angle fluorescence. The advantages of the method include the small amount of stationary phase employed together with the possibility of re-using the phase in order to carry out a large number of injections without the need for column re-packing. Also noteworthy is the small volume of 1,4-dioxane used to elute the BaP retained on the column and the small sample volumes required (9-10 ml) for achieving detection limits at the ng 1(-1) level. Thus, a methodology for BaP determination is obtained which complies with the requirements of the 98/83/EC Directive which fixes a maximum admissible concentration for this pollutant in waters for public consumption of 10 ng 1(-1). The variable angle spectra obtained are further processed by means of the multiple linear regression technique. The detection limit for BaP is 2.5 ng 1(-1), and the linear range is between 7.5 and 280 ng 1(-1).
引用
收藏
页码:451 / 456
页数:6
相关论文
共 30 条
[1]   A robust multisyringe system for process flow analysis -: Part I.: On-line dilution and single point titration of protolytes [J].
Albertús, F ;
Horstkotte, B ;
Cladera, A ;
Cerdá, V .
ANALYST, 1999, 124 (09) :1373-1381
[2]   Resolution of a multicomponent polycyclic aromatic hydrocarbon system in micellar media by linear variable angle fluorescence applying distinct chemometric techniques [J].
Amador-Hernández, J ;
Cladera, A ;
Estela, JM ;
López-de-Alba, PL ;
Cerdà, V .
ANALYST, 1998, 123 (11) :2235-2241
[3]   DETERMINATION OF PYRENE AND BENZO(A)PYRENE RESIDUES IN WATER BY DERIVATIVE SYNCHRONOUS SOLID-PHASE SPECTROFLUOROMETRY [J].
CAPITANVALLVEY, LF ;
CASTANEDA, RA ;
IRUELA, MD ;
QUERO, JLV .
MIKROCHIMICA ACTA, 1993, 112 (1-4) :55-62
[4]   Resolution of benzo[a]pyrene in complex mixtures of other polycyclic aromatic hydrocarbons.: Comparison of two spectrofluorimetric methods applied to water samples [J].
Eiroa, AA ;
Blanco, EV ;
Mahía, PL ;
Lorenzo, SM ;
Rodríguez, DP .
ANALYST, 2000, 125 (07) :1321-1326
[5]   Determination of polycyclic aromatic hydrocarbons (PAHs) in a complex mixture by second-derivative constant-energy synchronous spectrofluorimetry [J].
Eiroa, AA ;
Blanco, EV ;
Mahía, PL ;
Lorenzo, SM ;
Rodríguez, DP ;
Fernández, EF .
TALANTA, 2000, 51 (04) :677-684
[6]   Application of the effects of solvent and dissolved oxygen on the determination of benzo[a]pyrene by constant-wavelength synchronous spectrofluorimetry in smoke-flavouring [J].
Falcón, MSG ;
Amigo, SG ;
Yusty, MAL ;
Lage, BL ;
Lozano, JS .
TALANTA, 1999, 48 (02) :377-384
[7]   GASOLINE-ENGINE EXHAUST ANALYSIS USING CONSTANT ENERGY SYNCHRONOUS LUMINESCENCE SPECTROMETRY [J].
FILES, LA ;
JONES, BT ;
HANAMURA, S ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1440-1443
[8]  
Futoma D. J., 1981, POLYCYCLIC AROMATIC
[9]   ORGANICS IN WATER - SOLID-PHASE EXTRACTION ON A SMALL-SCALE [J].
JUNK, GA ;
RICHARD, JJ .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :451-454
[10]  
LIN Y, 1998, FENXI CESHI XUEBAO, V17, P66