Assessment of a seismic tuned mass damper with friction fail-safe mechanism for the vibration control of high-rise buildings

被引:9
作者
Sano, Takeshi [1 ]
Shirai, Kazutaka [2 ]
Yoshida, Osamu [3 ]
Nishikage, Taketomo [4 ]
机构
[1] Obayashi Corp, Div Technol, Tokyo, Japan
[2] Hokkaido Univ, Fac Engn, Sapporo, Hokkaido, Japan
[3] Obayashi Corp, Technol Res Inst, Tokyo, Japan
[4] Obayashi Corp, Dept Struct Engn, Tokyo, Japan
关键词
earthquake response; fail-safe (FS) mechanism; high-rise building; long-period; long-duration ground motion; tuned mass damper (TMD);
D O I
10.1002/stc.2831
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a method for mounting a tuned mass damper (TMD) at the top of a high-rise building through a fail-safe (FS) mechanism using a friction device to protect against strong earthquakes, such as those with long-period, long-duration ground motions. The control effect by the TMD with the proposed friction FS mechanism in single-degree-of-freedom and 30-degrees-of-freedom (30DOF) building models was numerically investigated by an earthquake response simulation. Also, the response for the same building models with TMDs incorporating different FS mechanisms (a bilinear viscous type and a displacement-dependent hardening type), TMDs with no FS mechanism, and no seismic protection (uncontrolled case) was examined for comparison. The obtained results demonstrated that use of the proposed friction FS mechanism prevents the TMD from operating beyond its design displacement limit; thus, this system avoids damage due to the TMD falling or colliding. Moreover, the proposed friction FS mechanism generally showed the most promising control effects among all 30DOF building models with TMD incorporating FS mechanism regarding the peak response of the TMD displacement and the building roof acceleration and displacement.
引用
收藏
页数:22
相关论文
共 34 条
[1]  
[Anonymous], Matlab
[2]  
Den Hartog J.P., 1947, Mechanical Vibrations
[3]   Advanced Technologies Applied at the New "Techno Station" Building in Tokyo, Japan [J].
Endo, Fumiaki ;
Yamanaka, Masayuki ;
Watnabe, Tetsumi ;
Kageyama, Mitsuru ;
Yoshida, Osamu ;
Katsumata, Hideo ;
Sano, Takeshi .
STRUCTURAL ENGINEERING INTERNATIONAL, 2011, 21 (04) :508-513
[4]   Torsional balance of nonlinear asymmetrical structures by means of a tuned mass damper [J].
Espinoza, Gilda ;
Almazan, Jose Luis ;
Benedetti, Franco ;
Jara, Carolina .
STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (11)
[5]   Tuned mass damper on a damped structure [J].
Fang, Huangcheng ;
Liu, Lin ;
Zhang, Dingli ;
Wen, Ming .
STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (03)
[6]   Optimal tuned mass damper for seismic applications and practical design formulas [J].
Hoang, Nam ;
Fujino, Yozo ;
Warnitchai, Pennung .
ENGINEERING STRUCTURES, 2008, 30 (03) :707-715
[7]   Reducing human-induced vibration of cross-laminated timber floor-Application of multi-tuned mass damper system [J].
Huang, Haoyu ;
Wang, Chang ;
Chang, Wen-Shao .
STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (02)
[8]  
Ito T., 2014, STEEL CONSTRUCT ENG, V21, P57, DOI [10.11273/jssc.21.84_57, DOI 10.11273/JSSC.21.84_57]
[9]  
Kaneko K, 2018, J STRUCT CONSTR ENG, V83, P1423, DOI [10.3130/aijs.83.1423, DOI 10.3130/AIJS.83.1423]
[10]  
Katsumata, 2010, REP OBAYASHI CORP TE, V74, P1