Microwave-assisted wet digestion with H2O2 at high temperature and pressure using single reaction chamber for elemental determination in milk powder by ICP-OES and ICP-MS

被引:55
|
作者
Muller, Edson I. [1 ]
Souza, Juliana P. [1 ]
Muller, Cristiano C. [1 ]
Muller, Aline L. H. [1 ]
Mello, Paola A. [1 ]
Bizzi, Cezar A. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
关键词
Hydrogen peroxide; Milk powder; Single reaction chamber; Microwave-assisted wet digestion; Elemental analysis; Trace elements; ACTIVE PHARMACEUTICAL INGREDIENTS; HYDROGEN-PEROXIDE; METALS DETERMINATION; TRACE-ELEMENTS; TOXIC ELEMENTS; SAMPLES; SPECTROMETRY; OXIDATION; DECOMPOSITION; FEASIBILITY;
D O I
10.1016/j.talanta.2016.05.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work a green digestion method which only used H2O2 as an oxidant and high temperature and pressure in the single reaction chamber system (SRC-UltraWave (TM)) was applied for subsequent elemental determination by inductively coupled plasma-based techniques. Milk powder was chosen to demonstrate the feasibility and advantages of the proposed method. Samples masses up to 500 mg were efficiently digested, and the determination of Ca, Fe, K, Mg and Na was performed by inductively coupled plasma optical emission spectrometry (ICP-OES), while trace elements (B, Ba, Cd, Cu, Mn, Mo, Pb, Sr and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS). Residual carbon (RC) lower than 918 mg L-1 of C was obtained for digests which contributed to minimizing interferences in determination by ICP-OES and ICP-MS. Accuracy was evaluated using certified reference materials NIST 1549 (non-fat milk powder certified reference material) and NIST 8435 (whole milk powder reference material). The results obtained by the proposed method were in agreement with the certified reference values (t-test, 95% confidence level). In addition, no significant difference was observed between results obtained by the proposed method and conventional wet digestion using concentrated HNO3. As digestion was performed without using any kind of acid, the characteristics of final digests were in agreement with green chemistry principles when compared to digests obtained using conventional wet digestion method with concentrated HNO3. Additionally, H2O2 digests were more suitable for subsequent analysis by ICP-based techniques due to of water being the main product of organic matrix oxidation. The proposed method was suitable for quality control of major components and trace elements present in milk powder in consonance with green sample preparation. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 24 条
  • [11] Microwave-assisted digestion using diluted HNO3 and H2O2 for macro and microelements determination in guarana samples by ICP OES
    Santos, Herick M.
    Coutinho, Janclei P.
    Amorim, Fabio Alan C.
    Lobo, Ivon P.
    Moreira, Luana S.
    Nascimento, Madson M.
    de Jesus, Raildo M.
    FOOD CHEMISTRY, 2019, 273 : 159 - 165
  • [12] Ultraviolet radiation combined with microwave-assisted wet digestion of Antarctic seaweeds for further determination of toxic elements by ICP-MS
    Mesko, Marcia F.
    Picoloto, Rochele S.
    Ferreira, Lizangela R.
    Costa, Vanize C.
    Pereira, Claudio M. P.
    Colepicolo, Pio
    Muller, Edson I.
    Flores, Erico M. M.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2015, 30 (01) : 260 - 266
  • [13] Study and determination of elemental impurities by ICP-MS in active pharmaceutical ingredients using single reaction chamber digestion in compliance with USP requirements
    Muller, Aline L. H.
    Oliveira, Jussiane S. S.
    Mello, Paola A.
    Muller, Edson I.
    Flores, Erico M. M.
    TALANTA, 2015, 136 : 161 - 169
  • [14] Determination of Platinum in Waste Platinum-loaded Carbon Catalyst Samples Using Microwave-assisted Sample Digestion and ICP-OES
    Ma, Yinbiao
    Wei, Xiaojuan
    ADVANCES IN ENERGY SCIENCE AND ENVIRONMENT ENGINEERING, 2017, 1829
  • [15] Microwave-Assisted Digestion Using Dilute Nitric Acid and Hydrogen Peroxide for Multielement Determination in Wheat Flour by ICP-MS
    Alhagri, Ibrahim A.
    Albeshry, Mosa
    JOURNAL OF CHEMISTRY, 2023, 2023
  • [16] Determination of trace elements in high-purity quartz samples by ICP-OES and ICP-MS: A normal-pressure digestion pretreatment method for eliminating unfavorable substrate Si
    Dong, Xuelin
    Xiong, Yuxiang
    Wang, Nan
    Song, Zhou
    Yang, Jie
    Qiu, Xiumei
    Zhu, Lihua
    ANALYTICA CHIMICA ACTA, 2020, 1110 : 11 - 18
  • [17] Determination of toxic elements in yerba mate by ICP-MS after diluted acid digestion under O2 pressure
    Pardinho, Renan B.
    Dalla Vecchia, Paula
    Mendes, Ana L. G.
    Bizzi, Cezar A.
    Mello, Paola A.
    Duarte, Fabio A.
    Flores, Erico M. M.
    FOOD CHEMISTRY, 2018, 263 : 37 - 41
  • [18] Microwave-assisted digestion using diluted acids for toxic element determination in medicinal plants by ICP-MS in compliance with United States pharmacopeia requirements
    Muller, Aline L. H.
    Muller, Edson I.
    Barin, Juliano S.
    Flores, Erico M. M.
    ANALYTICAL METHODS, 2015, 7 (12) : 5218 - 5225
  • [19] Microwave-assisted carbofuran degradation in the presence of GAC, ZVI and H2O2: Influence of reaction temperature and pH
    Remya, Neelancherry
    Lin, Jih-Gaw
    SEPARATION AND PURIFICATION TECHNOLOGY, 2011, 76 (03) : 244 - 252
  • [20] A rapid microwave-assisted acid extraction method based on the use of diluted HNO3-H2O2 followed by ICP-MS analysis for simultaneous determination of trace elements in coal samples
    Mketo, Nomvano
    Nomngongo, Philiswa N.
    Ngila, J. Catherine
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2015, 95 (05) : 453 - 465