Study on contrast effect of microbubbles as ultrasound contrast agents

被引:5
|
作者
Chan, M [1 ]
Soetanto, K [1 ]
机构
[1] Toin Univ Yokohama, Toin Human Sci & Technol Ctr, Fac Engn, Dept Control & Syst Engn,Aoba Ku, Yokohama, Kanagawa 225, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1998年 / 37卷 / 5B期
关键词
microbubbles; contrast effect; reference backscattered power; filtration;
D O I
10.1143/JJAP.37.3078
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this study, the contrast effect from different sized microbubbles is investigated both theoretically and experimentally. Theoretically, the reference back;scattered power is defined to evaluate the contrast effect of different sized microbubbles dispersed in the heart. in this study, the calculation results of two kinds of microbubbles of sizes 35 mu m and 2.2 mu m are discussed. From the calculation results obtained, it is found that the contrast effect from microbubbles of size 35 pm is better than that from microbubbles of size 2.2 mu m. The reason being that as the size of microbubbles decreases, a large portion of ultrasonic energy is lost due to absorption. Based on the same reason, microbubbles less than 10 mu m will cause an acoustic shadowing effect at a higher concentration of microbubbles, according to the calculation results. Experimentally, microbubbles of an average size of 35 mu m are produced, and by filtration, microbubbles of an average size of 2.1 mu m are collected. Then, the contrast effect produced from microbubbles before and after filtration are compared. It is observed that for both kinds of microbubbles, a good contrast effect is observed at a relatively low concentration of microbubble dispersion. However, distortion of images occurs at high concentrations. The acoustic shadowing effect is observed fur microbubbles of an average size of 2.1 mu m which can also be expected from the calculation results. On the other hand, the multiple-scattering effect which results in blurred images, occurs For microbubbles of an average size of 35 mu m.
引用
收藏
页码:3078 / 3081
页数:4
相关论文
共 50 条
  • [1] Targeting of microbubbles: contrast agents for ultrasound molecular imaging
    Wang, Shiying
    Hossack, John A.
    Klibanov, Alexander L.
    JOURNAL OF DRUG TARGETING, 2018, 26 (5-6) : 420 - 434
  • [2] Ultrasound contrast agents: microbubbles made simple for the pediatric radiologist
    Anush Sridharan
    John R. Eisenbrey
    Flemming Forsberg
    Norbert Lorenz
    Ludwig Steffgen
    Aikaterini Ntoulia
    Pediatric Radiology, 2021, 51 : 2117 - 2127
  • [3] Microbubbles as Ultrasound Contrast Agents for Molecular Imaging: Preparation and Application
    Unnikrishnan, Sunil
    Klibanov, Alexander L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (02) : 292 - 299
  • [4] Preparation of targeted microbubbles: ultrasound contrast agents for molecular imaging
    Klibanov, Alexander L.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (08) : 875 - 882
  • [5] Preparation of targeted microbubbles: ultrasound contrast agents for molecular imaging
    Alexander L. Klibanov
    Medical & Biological Engineering & Computing, 2009, 47 : 875 - 882
  • [6] Ultrasound contrast agents: microbubbles made simple for the pediatric radiologist
    Sridharan, Anush
    Eisenbrey, John R.
    Forsberg, Flemming
    Lorenz, Norbert
    Steffgen, Ludwig
    Ntoulia, Aikaterini
    PEDIATRIC RADIOLOGY, 2021, 51 (12) : 2117 - 2127
  • [7] Ultrasound Contrast Gas Microbubbles in the Vasculature
    Klibanov, Alexander L.
    INVESTIGATIVE RADIOLOGY, 2021, 56 (01) : 50 - 61
  • [8] CONTRAST AGENTS FOR DIAGNOSTIC ULTRASOUND - DEVELOPMENT AND EVALUATION OF POLYMER-COATED MICROBUBBLES
    WHEATLEY, MA
    SCHROPE, B
    SHEN, P
    BIOMATERIALS, 1990, 11 (09) : 713 - 717
  • [9] Ultrasound contrast agents
    Cachard, Christian
    Basset, Olivier
    PHYSICS FOR MEDICAL IMAGING APPLICATIONS, 2007, 240 : 137 - +
  • [10] Ultrasound contrast agents
    Albrecht, T
    Hohmann, J
    RADIOLOGE, 2003, 43 (10): : 793 - 804