Coronary flow reserve: measurement with transthoracic Doppler echocardiography is reproducible and comparable with positron emission tomography

被引:151
作者
Saraste, M
Koskenvuo, JW
Knuuti, J
Toikka, JO
Laine, H
Niemi, P
Sakuma, H
Hartiala, JJ
机构
[1] Univ Turku, Cent Hosp, Dept Clin Physiol, SF-20500 Turku, Finland
[2] Univ Turku, Cent Hosp, Dept Radiol, SF-20500 Turku, Finland
[3] Univ Turku, Turku PET Ctr, SF-20500 Turku, Finland
[4] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
来源
CLINICAL PHYSIOLOGY | 2001年 / 21卷 / 01期
关键词
blood flow; coronary flow reserve (CFR); echocardiography; positron emission tomography (PET);
D O I
10.1046/j.1365-2281.2001.00296.x
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Detection of early vascular changes indicated by lowered coronary flow reserve (CFR) would allow early treatment and prevention of atherosclerosis. The purpose of this study was to test whether it is possible to reproducibly measure CFR with transthoracic Doppler echocardiography (TTE) in healthy volunteers. We measured CFR using dipyridamole infusion in ten healthy male volunteers with two methods: TTE and positron emission tomography (PET) with oxygen-15-labelled water (group A). However, CFR was assessed twice with TTE in eight healthy male volunteers (group B) to study the reproducibility of this method. We compared CFRs obtained using TTE flow measurements in the left anterior descending coronary artery (LAD) and PET flow measurements in the corresponding myocardial area. Coronary flow in LAD could be measured in all subjects using TTE. By TTE, an average CFR based on peak diastolic flow velocity (PDV) was 2.72 +/- 1.16, mean diastolic flow velocity (MDV) 2.56 +/- 1.06 and velocity time integral (VTI) 1.87 +/- 0.49. The results were reproducible in two repeated TTE studies (coefficient of variation in MDV 6.1 +/- 4.3%, n = 8). By PET, CFR was 2.52 +/- 0.84. CFR assessed by TTE correlated closely with that measured by PET (MDV r = 0.942, P <0.001; PDV r = 0.912, P <0.002 and VTI r=0.888, P <0.006) and intraclass correlation was 0.929 (MDV) and tolerance limits for differences of CFRs was -0.78 to 0.72. We show that CFR measured by TTE has an excellent correlation with CFR measured by PET. We also found that TTE measurements of CFR were highly reproducible.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 37 条
[1]   Current concepts of coronary flow reserve for clinical decision making during cardiac catheterisation [J].
Baumgart, D ;
Haude, M ;
Liu, FQ ;
Ge, JB ;
Goerge, G ;
Erbel, R .
AMERICAN HEART JOURNAL, 1998, 136 (01) :136-149
[2]   Clinical applications of myocardial perfusion assessments made with oxygen-15 water and positron emission tomography [J].
Bergmann, SR .
CARDIOLOGY, 1997, 88 (01) :71-79
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[5]   MEASUREMENT OF ABSOLUTE EPICARDIAL CORONARY-ARTERY FLOW AND FLOW RESERVE WITH BREATH-HOLD CINE PHASE-CONTRAST MAGNETIC-RESONANCE-IMAGING [J].
CLARKE, GD ;
ECKELS, R ;
CHANEY, C ;
SMITH, D ;
DITTRICH, J ;
HUNDLEY, WG ;
NESSAIVER, M ;
LI, HF ;
PARKEY, RW ;
PESHOCK, RM .
CIRCULATION, 1995, 91 (10) :2627-2634
[6]  
CROUZEL C, 1993, RADIOPHARMACEUTICALS, P45
[7]   Transthoracic echocardiographic measurement of coronary blood flow and reserve [J].
Crowley, JJ ;
Shapiro, LM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (04) :337-343
[8]   EARLY DETECTION OF ABNORMAL CORONARY FLOW RESERVE IN ASYMPTOMATIC MEN AT HIGH-RISK FOR CORONARY-ARTERY DISEASE USING POSITRON EMISSION TOMOGRAPHY [J].
DAYANIKLI, F ;
GRAMBOW, D ;
MUZIK, O ;
MOSCA, L ;
RUBENFIRE, M ;
SCHWAIGER, M .
CIRCULATION, 1994, 90 (02) :808-817
[9]   ASSESSMENT OF CORONARY-ARTERY DISEASE SEVERITY BY POSITRON EMISSION TOMOGRAPHY - COMPARISON WITH QUANTITATIVE ARTERIOGRAPHY IN 193 PATIENTS [J].
DEMER, LL ;
GOULD, KL ;
GOLDSTEIN, RA ;
KIRKEEIDE, RL ;
MULLANI, NA ;
SMALLING, RW ;
NISHIKAWA, A ;
MERHIGE, ME .
CIRCULATION, 1989, 79 (04) :825-835
[10]   Assessing the Hemodynamic Significance of Coronary Artery Stenoses: Analysis of Translesional Pressure-Flow Velocity Relations in Patients [J].
Donohue, Thomas J. ;
Kern, Morton J. ;
Aguirre, Frank V. ;
Bach, Richard G. ;
Wolford, Thomas ;
Bell, Calvin A. ;
Segal, Jerome .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) :449-458