Iterative optimization of tail breaking force of 1 mil wire thermosonic ball bonding processes and the influence of plasma cleaning

被引:26
作者
Lee, J. [1 ]
Mayer, M.
Zhou, Y.
Hong, S. J.
机构
[1] Univ Waterloo, Ctr Adv Mat Joining, Dept Mech & Mechatron Engn, Microjoining Lab, Waterloo, ON N2L 3G1, Canada
[2] MK Electron Co Ltd, Yongin, South Korea
关键词
wire bonding; thermosonic; tail breaking force; leadframe; tensile test;
D O I
10.1016/j.mejo.2007.07.095
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An online tail breaking force measurement method is developed with a proximity sensor between wire clamp and horn. The wire under the tensile load measures about 1.5 cm extending from the bond location to the wire clamp. To increase the sensitivity, the bondhead speed is reduced to 2 mm/s during breaking the tail bond. It takes roughly 10 ms to break the tail bond. The force resolution of the method is estimated to be better than 5.2 mN. An automatic wire bonder used to continuously bond up to 80-wire loops while recording the on-line proximity signals. All wires are directed perpendicular to the ultrasound direction. The tail breaking force for each bond is evaluated from the signal and shown automatically on the bonder within 2 min after bonding. Results are obtained for a typical Au wire and a typical Cu wire bonding process. Both wires are 25 mm in diameter and bonded on Ag plated diepads of standard leadframes at 220 degrees C. An average Cu tail breaking force of higher than 50 mN is obtained if the leadframe is plasma cleaned before the bonding with 100% Ar for 5 min. This result is comparable to that obtained with Au wire. The standard deviation of the Cu tail breaking force is about twice that obtained with Au wire. The tail breaking force depends on the bonding parameters, metallization variation, and cleanliness of the bond pad. The cleanliness of the bonding pad is more important with Cu wire than with Au wire. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:842 / 847
页数:6
相关论文
共 13 条
[1]   Improving the wire bonding process quality using statistically designed experiments [J].
Antony, J .
MICROELECTRONICS JOURNAL, 1999, 30 (02) :161-168
[2]  
Beleran J., 2005, P SEMICON, P1
[3]  
CALPITO D, 2004, P SEMICON, P1
[4]   Effect of plasma treatment of Au-Ni-Cu bond pads on process window's of Au wire bonding [J].
Chan, YH ;
Kim, JK ;
Liu, DM ;
Liu, PCK ;
Cheung, YM ;
Ng, MW .
IEEE TRANSACTIONS ON ADVANCED PACKAGING, 2005, 28 (04) :674-684
[5]   Two capillary solutions for ultra-fine-pitch wire bonding and insulated wire bonding [J].
Goh, K. S. ;
Zhong, Z. W. .
MICROELECTRONIC ENGINEERING, 2007, 84 (02) :362-367
[6]  
HARMAN GG, 1997, WIRE BONDING MICROEL
[7]  
KENNY I, 1997, PATHAL PHYSL OPT, V17, P263
[8]  
Lambert S, 2006, CIRCUIT WORLD, V32, P36, DOI 10.1108/03056120610683612
[9]   A surface analysis on oxygen plasma-cleaned gold pattern-plated substrates for wire bondability [J].
Lin, YS .
SURFACE & COATINGS TECHNOLOGY, 2003, 173 (01) :47-57
[10]   Effect of wire diameter on the thermosonic bond reliability [J].
Murali, S ;
Srikanth, N ;
Vath, CJ .
MICROELECTRONICS RELIABILITY, 2006, 46 (2-4) :467-475