Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking

被引:236
作者
Keall, PJ
Joshi, S
Vedam, SS
Siebers, JV
Kini, VR
Mohan, R
机构
[1] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[2] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC 27514 USA
[3] Virginia Commonwealth Univ, Dept Radiat Oncol, Richmond, VA 23298 USA
[4] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
4D radiotherapy; deformable image registration; treatment planning;
D O I
10.1118/1.1879152
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. Temporal anatomic changes can occur for many reasons, though the focus of the current investigation is respiration motion for lung tumors. The aim of this study was to develop 4D radiotherapy treatment-planning methodology for DMLC-based respiratory motion tracking. A 4D computed tomography (CT) scan consisting of a series of eight 3D CT image sets acquired at different respiratory phases was used for treatment planning. Deformable image registration was performed to map each CT set from the peak-inhale respiration phase to the CT image sets corresponding to subsequent respiration phases. Deformable registration allows the contours defined on the peak-inhale CT to be automatically transferred to the other respiratory phase CT image sets. Treatment planning was simultaneously performed on each of the eight 3D image sets via automated scripts in which the MLC-defined beam aperture conforms to the PTV (which in this case equaled the GTV due to CT scan length limitations) plus a penumbral margin at each respiratory phase. The dose distribution from each respiratory phase CT image set was mapped back to the peak-inhale CT image set for analysis. The treatment intent of 4D planning is that the radiation beam defined by the DMLC tracks the respiration-induced target motion based on a feedback loop including the respiration signal to a real-time MLC controller. Deformation with respiration was observed for the lung tumor and normal tissues. This deformation was verified by examining the mapping of high contrast objects, such as the lungs and cord, between image sets. For the test case, dosimetric reductions for the cord, heart, and lungs were found for 4D planning compared with 3D planning. 4D radiotherapy planning for DMLC-based respiratory motion tracking is feasible and may offer tumor dose escalation and/or a reduction in treatment-related complications. However, 4D planning requires new planning tools, such as deformable registration and automated treatment planning on multiple CT image sets. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:942 / 951
页数:10
相关论文
共 101 条
  • [1] [Anonymous], 1993, 50 ICRU
  • [2] [Anonymous], 1999, 62 ICRU
  • [3] Determination of ventilatory liver movement via radiographic evaluation of diaphragm position
    Balter, JM
    Dawson, LA
    Kazanjian, S
    McGinn, C
    Brock, KK
    Lawrence, T
    Ten Haken, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01): : 267 - 270
  • [4] Breathing pattern in humans: diversity and individuality
    Benchetrit, G
    [J]. RESPIRATION PHYSIOLOGY, 2000, 122 (2-3): : 123 - 129
  • [5] Adapting inverse planning to patient and organ geometrical variation:: algorithm and implementation
    Birkner, M
    Yan, D
    Alber, M
    Liang, J
    Nüsslin, F
    [J]. MEDICAL PHYSICS, 2003, 30 (10) : 2822 - 2831
  • [6] STEREOTAXIC HIGH-DOSE FRACTION RADIATION-THERAPY OF EXTRACRANIAL TUMORS USING AN ACCELERATOR - CLINICAL-EXPERIENCE OF THE FIRST 31 PATIENTS
    BLOMGREN, H
    LAX, I
    NASLUND, I
    SVANSTROM, R
    [J]. ACTA ONCOLOGICA, 1995, 34 (06) : 861 - 870
  • [7] Inclusion of organ deformation in dose calculations
    Brock, KK
    McShan, DL
    Ten Haken, RK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2003, 30 (03) : 290 - 295
  • [8] Technical note: Creating a four-dimensional model of the liver using finite element analysis
    Brock, KK
    Hollister, SJ
    Dawson, LA
    Balter, JM
    [J]. MEDICAL PHYSICS, 2002, 29 (07) : 1403 - 1405
  • [9] Automated generation of a four-dimensional model of the liver using warping and mutual information
    Brock, KM
    Balter, JM
    Dawson, LA
    Kessler, ML
    Meyer, CR
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1128 - 1133
  • [10] Brock Kristy K, 2002, J Appl Clin Med Phys, V3, P241, DOI 10.1120/1.1474229