AC motor drives;
Gaussian noise;
permanent magnet synchronous motor (PMSM);
rotor position estimation;
signal-to-noise ratio (SNR);
INDUCTION MACHINES;
SENSORLESS CONTROL;
MOTOR;
OBSERVER;
VELOCITY;
FLUX;
ZERO;
D O I:
10.1109/TEC.2014.2354075
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
High-frequency injection (HFI) is an alternative method to estimate permanent magnet synchronous motor (PMSM) rotor position using magnetic saliency. Once the maximum fundamental electrical frequency and the power converter switching frequency are set, the HFI voltage amplitude tuning is generally based on trial and error. This paper proposes a methodology to select the appropriate high-frequency signal injection voltage amplitude for rotor position estimation. The technique is based on an analytical model taking into account the noise in the voltage supply to derive the resulting currents containing the information on the rotor position. This model allows setting the injection voltage amplitude that leads to the maximum acceptable position error for a given signal-to-noise ratio and a speed range. The approach is validated with the analytical and the global drive models through extensive simulations. Experimental results on a 1-kW PMSM drive confirm the interest of the proposed solution.
引用
收藏
页码:349 / 358
页数:10
相关论文
共 25 条
[21]
Shuanghe Yu, 2010, 2010 3rd International Symposium on Systems and Control in Aeronautics and Astronautics (ISSCAA 2010), P1131, DOI 10.1109/ISSCAA.2010.5632731
Shuanghe Yu, 2010, 2010 3rd International Symposium on Systems and Control in Aeronautics and Astronautics (ISSCAA 2010), P1131, DOI 10.1109/ISSCAA.2010.5632731