A comparison of the vasotrac with invasive arterial blood pressure monitoring in children after pediatric cardiac surgery

被引:21
作者
Cua, CL
Thornas, K
Zurakowski, D
Laussen, PC
机构
[1] Childrens Hosp Boston, Dept Cardiol, Boston, MA 02115 USA
[2] Childrens Hosp Boston, Dept Orthopaed Surg, Boston, MA 02115 USA
关键词
D O I
10.1213/01.ANE.0000149591.67207.05
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
The Vasotrac is a device that provides near-continuous and noninvasive arterial blood pressure monitoring and may be an alternative to direct intraarterial measurement. It has been evaluated in adult patients, but minimal information is available for pediatric patients. We evaluated agreement between measurements of arterial blood pressure and heart rate obtained from the Vasotrac versus an arterial catheter in a pediatric population. Children undergoing corrective cardiac surgery were enrolled. Simultaneous arterial blood pressure measurements were obtained postoperatively from the Vasotrac unit and an arterial catheter. Bland-Altman plots were constructed to assess agreement. Paired correlation analysis, bias, and precision calculations were performed. Sixteen patients, mean age 10.1 +/- 2.3 yr and weight 34.6 +/- 11.9 kg, were enrolled. Four-thousand-one-hundred-two paired measurements were obtained. Arterial blood pressures measured noninvasively correlated with catheter measurements with Pearson r values of 0.90, 0.80, and 0.91 for systolic, diastolic, and mean arterial blood pressures, respectively (all P < 0.001). There was excellent agreement between arterial blood pressure measurement methods. Absolute mean differences based on mixed-model regression with 95% confidence intervals were 4.0 mm Hg (3.0-5.0 mm Hg), 4.3 mm Hg (3.1-5.5 mm Hg), and 3.5 mm Hg (2.5-4.0 mm Hg) for systolic blood pressure, diastolic blood pressure, and mean blood pressure, respectively. Arterial blood pressure measurements obtained from the Vasotrac agreed well with invasive arterial monitoring in pediatric patients.
引用
收藏
页码:1289 / 1294
页数:6
相关论文
共 26 条
[1]  
[Anonymous], 2002, ANESTHESIOL CLIN N A
[2]  
Armitage P., 2002, STAT METHODS MED RES, P358
[3]  
*ASS ADV MED INSTR, 1992, PROP STAND EL AUT SP
[4]  
Bause G S, 1986, J Clin Monit, V2, P262, DOI 10.1007/BF02851174
[5]   A new noninvasive method to measure blood pressure - Results of a multicenter trial [J].
Belani, K ;
Ozaki, M ;
Hynson, J ;
Hartmann, T ;
Reyford, H ;
Martino, JM ;
Poliac, M ;
Miller, R .
ANESTHESIOLOGY, 1999, 91 (03) :686-692
[6]   Accuracy of radial artery blood pressure determination with the Vasotrac™ [J].
Belani, KG ;
Buckley, JJ ;
Poliac, MO .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (05) :488-496
[7]   Do the Finapres™ and Colin® radial artery tonometer measure the same blood pressure changes following deflation of thigh cuffs? [J].
Birch, AA ;
Morris, SL .
PHYSIOLOGICAL MEASUREMENT, 2003, 24 (03) :653-660
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   COMPARATIVE ACCURACIES OF A FINGER BLOOD-PRESSURE MONITOR AND AN OSCILLOMETRIC BLOOD-PRESSURE MONITOR [J].
EPSTEIN, RH ;
HUFFNAGLE, S ;
BARTKOWSKI, RR .
JOURNAL OF CLINICAL MONITORING, 1991, 7 (02) :161-167
[10]  
Frezza EE, 1998, AM SURGEON, V64, P127