Point shear wave speed measurement in differentiating benign and malignant focal liver lesions

被引:24
作者
Dong, Yi [1 ]
Wang, Wen-Ping [1 ]
Xu, Yadan [2 ]
Cao, Jiaying [1 ]
Mao, Feng [1 ]
Dietrich, Cristoph F. [3 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Ultrasound, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Shanghai Inst Med Imaging, Shanghai, Peoples R China
[3] Caritas Krankenhaus Bad Mergentheim, Med Klin 2, Bad Mergentheim, Germany
基金
中国国家自然科学基金;
关键词
ElastPQ; shear wave speed; focal liver lesions; differential diagnosis; RADIATION FORCE IMPULSE; CLINICAL-USE; HEPATOCELLULAR-CARCINOMA; DIAGNOSTIC PERFORMANCE; EFSUMB GUIDELINES; ELASTOGRAPHY; REPRODUCIBILITY; RECOMMENDATIONS; TUMORS; QUANTIFICATION;
D O I
10.11152/mu-1142
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: To investigate the value of ElastPQ measurement for differential diagnosis of benign and malignant focal liver lesions (FLLs) by using histologic results as a reference standard. Material and methods: A total of 154 patients were included. ElastPQ measurement was performed for each lesion in which the shear wave speed (SWS) was measured. The difference in SWS and SWS ratio of FLL to surrounding liver were evaluated, and the cut off value was investigated. Receiver operating characteristic (ROC) curve was plotted to evaluate the diagnostic performance. Histology as a gold standard was obtained by surgery in all patients. Results: A total of 154 lesions including 129 (83.7 %) malignant FLLs and 25 (16.3 %) benign ones were analysed. The SWS of malignant and benign FLLs was significantly different, 2.77 +/- 0.68 m/s and 1.57 +/- 0.55 m/s (p<0.05). The SWS ratio of each FLL to surrounding liver parenchyma was 2.23 +/- 0.49 for malignant and 1.14 +/- 0.36 for benign FLLs (p<0.05). The cut off value for differential diagnosis was 2.06 m/s for SWS and 1.67 for SWS ratio. Conclusions: ElastPQ measurement provides reliable quantitative stiffness information of FLLs and may be helpful in the differential diagnosis between malignant and benign FLLs.
引用
收藏
页码:259 / 264
页数:6
相关论文
共 38 条
[1]   EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 1: Basic Principles and Technology [J].
Bamber, J. ;
Cosgrove, D. ;
Dietrich, C. F. ;
Fromageau, J. ;
Bojunga, J. ;
Calliada, F. ;
Cantisani, V. ;
Correas, J. -M. ;
D'Onofrio, M. ;
Drakonaki, E. E. ;
Fink, M. ;
Friedrich-Rust, M. ;
Gilja, O. H. ;
Havre, R. F. ;
Jenssen, C. ;
Klauser, A. S. ;
Ohlinger, R. ;
Saftoiu, A. ;
Schaefer, F. ;
Sporea, I. ;
Piscaglia, F. .
ULTRASCHALL IN DER MEDIZIN, 2013, 34 (02) :169-184
[2]   Shear wave elastography of thyroid nodules in routine clinical practice: preliminary observations and utility for detecting malignancy [J].
Bhatia, Kunwar S. S. ;
Tong, Cina S. L. ;
Cho, Carmen C. M. ;
Yuen, Edmund H. Y. ;
Lee, Yolanda Y. P. ;
Ahuja, Anil T. .
EUROPEAN RADIOLOGY, 2012, 22 (11) :2397-2406
[3]   Characterization of small nodules in cirrhosis by assessment of vascularity: The problem of hypovascular hepatocellular carcinoma [J].
Bolondi, L ;
Gaiani, S ;
Celli, N ;
Goffieri, R ;
Grigioni, WF ;
Leoni, S ;
Venturi, AM ;
Piscaglia, F .
HEPATOLOGY, 2005, 42 (01) :27-34
[4]   Focal nodular hyperplasia and hepatocellular adenoma: The value of shear wave elastography for differential diagnosis [J].
Brunel, Thomas ;
Guibal, Aymeric ;
Boularan, Camille ;
Ducerf, Christian ;
Mabrut, Jean-Yves ;
Bancel, Brigitte ;
Boussel, Loic ;
Rode, Agnes .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) :2059-2064
[5]   Assessment of Liver Viscoelasticity by Using Shear Waves Induced by Ultrasound Radiation Force [J].
Chen, Shigao ;
Sanchez, William ;
Callstrom, Matthew R. ;
Gorman, Brian ;
Lewis, Jason T. ;
Sanderson, Schuyler O. ;
Greenleaf, James F. ;
Xie, Hua ;
Shi, Yan ;
Pashley, Michael ;
Shamdasani, Vijay ;
Lachman, Michael ;
Metz, Stephen .
RADIOLOGY, 2013, 266 (03) :964-970
[6]   ACOUSTIC RADIATION FORCE IMPULSE ELASTOGRAPHY FOR THE EVALUATION OF FOCAL SOLID HEPATIC LESIONS: PRELIMINARY FINDINGS [J].
Cho, Seung Hyun ;
Lee, Jae Young ;
Han, Joon Koo ;
Choi, Byung Ihn .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (02) :202-208
[7]   Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave Elastography [J].
Correas, Jean-Michel ;
Tissier, Anne-Marie ;
Khairoune, Ahmed ;
Vassiliu, Viorel ;
Mejean, Arnaud ;
Helenon, Olivier ;
Memo, Richard ;
Barr, Richard G. .
RADIOLOGY, 2015, 275 (01) :280-289
[8]   EFSUMB Guidelines and Recommendations on the Clinical Use of Ultrasound Elastography. Part 2: Clinical Applications [J].
Cosgrove, D. ;
Piscaglia, F. ;
Bamber, J. ;
Bojunga, J. ;
Correas, J. -M. ;
Gilja, O. H. ;
Klauser, A. S. ;
Sporea, I. ;
Calliada, F. ;
Cantisani, V. ;
D'Onofrio, M. ;
Drakonaki, E. E. ;
Fink, M. ;
Friedrich-Rust, M. ;
Fromageau, J. ;
Havre, R. F. ;
Jenssen, C. ;
Ohlinger, R. ;
Saftoiu, A. ;
Schaefer, F. ;
Dietrich, C. F. .
ULTRASCHALL IN DER MEDIZIN, 2013, 34 (03) :238-253
[9]   Acoustic radiation force impulse with shear wave speed quantification of pancreatic masses: A prospective study [J].
D'Onofrio, Mirko ;
De Robertis, Riccardo ;
Crosara, Stefano ;
Poli, Cristina ;
Canestrini, Stefano ;
Demozzi, Emanuele ;
Mucelli, Roberto Pozzi .
PANCREATOLOGY, 2016, 16 (01) :106-109
[10]   Acoustic radiation force impulse elastography in distinguishing hepatic haemangiomata from metastases: preliminary observations [J].
Davies, G. ;
Koenen, M. .
BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1006) :939-943