Magnesium and calcium determination in desalted crude oil by direct sampling graphite furnace atomic absorption spectrometry

被引:15
作者
Seeger, Tassia S. [1 ]
Muller, Edson I. [1 ]
Mesko, Marcia F. [2 ]
Duarte, Fabio A. [1 ]
机构
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Pelotas, Ctr Ciencias Quim Farmaceut & Alimentos, BR-96160000 Capao Do Leao, RS, Brazil
关键词
Direct sampling; Graphite furnace atomic absorption spectrometry; Magnesium; Calcium; Petroleum; MICROWAVE-INDUCED COMBUSTION; PLASMA-MASS SPECTROMETRY; ICP-MS; ELEMENT DETERMINATION; CHLORIDE SALTS; TRACE-ELEMENTS; DIGESTION; EXTRACTION; PETROLEUM; MG;
D O I
10.1016/j.fuel.2018.09.108
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS) was proposed for Mg and Ca determination in desalted crude oil. A Zeeman-effect background correction system with variable magnetic field was used and measurements were carried out with low and high sensitivity. Pyrolysis and atomization temperatures, calibration with aqueous standards and the effect of sample mass to be introduced into the atomizer were evaluated. The use of chemical modifiers was not necessary for both elements. For Mg determination, two sensitivity conditions (high and low, respectively) were used: i) main absorption line (285.2 nm), 2-field mode (0.8 T) and gas stop flow during the atomization and ii) secondary absorption line (202.6 nm), 2-field mode (0.8 T) and gas stop flow during the atomization. For Ca determination, three low-sensitivity conditions using the main absorption line (422.7 nm) and variable magnetic field were used: i) 3-field dynamic mode (0.6-0.8 T) and gas stop flow during the atomization, ii) 3-field dynamic mode (0.4-0.8 T) and gas stop flow during the atomization and iii) 3-field dynamic mode (0.6-0.8 T) and gas flow during the atomization. The characteristic mass and limit of quantification for the highest sensitivity condition were 0.3 pg and 1.2 ng g(-1) for Mg and 4.8 pg and 0.1 mu g g(-1) for Ca, respectively. For all sensitivity conditions, good linearity (R-2 above 0.997) and relative standard deviation below 14% were achieved. Accuracy for DS-GF AAS method was evaluated by results comparison with those obtained by GF AAS after microwave-assisted digestion, which were in agreement. Additionally, recovery tests were carried out and recoveries for both analytes ranged from 92 to 107%. The use of DS-GF AAS provides some advantages such as simplicity, low risk of contamination and up to twelve measurements can be performed per hour.
引用
收藏
页码:1483 / 1488
页数:6
相关论文
共 50 条
[31]   Slurry sampling graphite furnace atomic absorption spectrometry: determination of trace metals in mineral coal [J].
Silva, MM ;
Goreti, M ;
Vale, R ;
Caramao, EB .
TALANTA, 1999, 50 (05) :1035-1043
[32]   Determination of titanium by slurry sampling graphite furnace atomic absorption spectrometry with the use of fluoride modifiers [J].
Torunn Marie Sørlie ;
Grethe Wibetoe .
Analytical and Bioanalytical Chemistry, 2003, 376 :721-727
[33]   Determination of cadmium and lead in fresh meat by slurry sampling graphite furnace atomic absorption spectrometry [J].
Ferreira Damin, Isabel Cristina ;
Zmozinski, Ariane Vanessa ;
Borges, Aline Rocha ;
Rodrigues Vale, Maria Goreti ;
da Silva, Marcia Messias .
ANALYTICAL METHODS, 2011, 3 (06) :1379-1385
[34]   Determination of Selenium in Milk by Graphite Furnace Atomic Absorption Spectrometry [J].
Vongkul, A. ;
Dejmanee, S. .
ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (17) :10007-10010
[35]   Method for cadmium and lead longitudinal profiles determination in hair by solid sampling graphite furnace atomic absorption spectrometry [J].
Nomura, Cassiana Seimi ;
Oliveira, Pedro Vitoriano .
ANALYTICAL METHODS, 2010, 2 (01) :49-53
[36]   DIRECT DETERMINATION OF MAGNESIUM AT THE 1-PERCENT LEVEL IN SOLID SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BELARRA, MA ;
LAVILLA, I ;
CASTILLO, JR .
ANALYTICAL SCIENCES, 1995, 11 (04) :651-656
[37]   Direct determination of cobalt and zinc in samples of different volatility by means of solid sampling-graphite furnace atomic absorption spectrometry [J].
Belarra, MA ;
Crespo, C ;
Martínez-Garbayo, MR ;
Resano, M .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (10) :1847-1858
[38]   DIRECT DETERMINATION OF ZINC IN SERUM BY ZEEMAN ATOMIC-ABSORPTION SPECTROMETRY WITH A GRAPHITE-FURNACE [J].
DHAESE, PC ;
LAMBERTS, LV ;
VANHEULE, AO ;
DEBROE, ME .
CLINICAL CHEMISTRY, 1992, 38 (12) :2439-2443
[39]   Determination of Dysprosium in Rock Vitrified with Lithium Tetraborate by Solid Sampling Graphite Furnace Atomic Absorption Spectrometry [J].
Araki, Toshimitsu ;
Inui, Tetsuo ;
Nakamura, Toshihiro .
BUNSEKI KAGAKU, 2015, 64 (08) :595-600
[40]   Simultaneous determination of calcium and magnesium in urines by flame atomic absorption spectrometry [J].
Bai, Y ;
Ouyang, JM ;
Bai, Y ;
Chen, ML .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (08) :1016-1019