Direct sampling graphite furnace atomic absorption spectrometry (DS-GF AAS) was proposed for Mg and Ca determination in desalted crude oil. A Zeeman-effect background correction system with variable magnetic field was used and measurements were carried out with low and high sensitivity. Pyrolysis and atomization temperatures, calibration with aqueous standards and the effect of sample mass to be introduced into the atomizer were evaluated. The use of chemical modifiers was not necessary for both elements. For Mg determination, two sensitivity conditions (high and low, respectively) were used: i) main absorption line (285.2 nm), 2-field mode (0.8 T) and gas stop flow during the atomization and ii) secondary absorption line (202.6 nm), 2-field mode (0.8 T) and gas stop flow during the atomization. For Ca determination, three low-sensitivity conditions using the main absorption line (422.7 nm) and variable magnetic field were used: i) 3-field dynamic mode (0.6-0.8 T) and gas stop flow during the atomization, ii) 3-field dynamic mode (0.4-0.8 T) and gas stop flow during the atomization and iii) 3-field dynamic mode (0.6-0.8 T) and gas flow during the atomization. The characteristic mass and limit of quantification for the highest sensitivity condition were 0.3 pg and 1.2 ng g(-1) for Mg and 4.8 pg and 0.1 mu g g(-1) for Ca, respectively. For all sensitivity conditions, good linearity (R-2 above 0.997) and relative standard deviation below 14% were achieved. Accuracy for DS-GF AAS method was evaluated by results comparison with those obtained by GF AAS after microwave-assisted digestion, which were in agreement. Additionally, recovery tests were carried out and recoveries for both analytes ranged from 92 to 107%. The use of DS-GF AAS provides some advantages such as simplicity, low risk of contamination and up to twelve measurements can be performed per hour.
引用
收藏
页码:1483 / 1488
页数:6
相关论文
共 50 条
[21]   Direct determination of trace arsenic in coal by slurry-sampling graphite-furnace atomic absorption spectrometry [J].
Chen, SZ .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 2004, 24 (10) :1267-1269
[22]   Determination of Ultra-Trace Levels of Calcium in Steel by Graphite Furnace Atomic Absorption Spectrometry [J].
Hirotsugu Minami ;
Qiangbin Zhang ;
Sadanobu Inoue ;
Ikuo Atsuya .
Analytical Sciences, 1997, 13 :199-203
[23]   Determination of ultra-trace levels of calcium in steel by graphite furnace atomic absorption spectrometry [J].
Minami, H ;
Zhang, QB ;
Inoue, S ;
Atsuya, I .
ANALYTICAL SCIENCES, 1997, 13 (02) :199-203
[24]   High purity polyimide analysis by solid sampling graphite furnace atomic absorption spectrometry [J].
Santos, Rafael F. ;
Carvalho, Gabriel S. ;
Duarte, Fabio A. ;
Bolzan, Rodrigo C. ;
Flores, Erico M. M. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 129 :42-48
[25]   Slurry sampling for the determination of thallium in soils and sediments by graphite furnace atomic absorption spectrometry [J].
Dobrowolski, R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (7-8) :1294-1300
[26]   Fast emulsion-based method for simultaneous determination of Co, Cu, Pb and Se in crude oil, gasoline and diesel by graphite furnace atomic absorption spectrometry [J].
Luz, Maciel S. ;
Nascimento, Angerson N. ;
Oliveira, Pedro V. .
TALANTA, 2013, 115 :409-413
[27]   Direct Determination of Molybdenum in Milk and Infant Food Samples Using Slurry Sampling and Graphite Furnace Atomic Absorption Spectrometry [J].
de Amorim, Flavia Regina ;
Franco, Milton Batista ;
Nascentes, Clesia Cristina ;
Borba da Silva, Jose Bento .
FOOD ANALYTICAL METHODS, 2011, 4 (01) :41-48
[28]   Determination of calcium and magnesium in wheat flour by suspension sampling-flame atomic absorption spectrometry [J].
Liu, LH ;
Zhang, QK ;
Hu, Y .
SPECTROSCOPY AND SPECTRAL ANALYSIS, 1999, 19 (03) :424-425
[29]   Direct determination of nickel in xylene solutions of raw material for catalytic cracking with application of graphite furnace atomic absorption spectrometry [J].
Kowalewska, Zofia .
ANALYTICAL METHODS, 2013, 5 (01) :192-201
[30]   Determination of gold in geological materials by carbon slurry sampling graphite furnace atomic absorption spectrometry [J].
Dobrowolski, Ryszard ;
Kurylo, Michal ;
Otto, Magdalena ;
Mroz, Agnieszka .
TALANTA, 2012, 99 :750-757