Surface finishes on stainless steel reduce bacterial attachment and early biofilm formation: Scanning electron and atomic force microscopy study

被引:154
|
作者
Arnold, JW
Bailey, GW
机构
[1] USDA, Richard B Russell Agr Res Ctr, Athens, GA 30605 USA
[2] US EPA, Natl Exposure Res Lab, Ecosyst Res Div, Athens, GA 30605 USA
关键词
biofilm; bacteria; pathogen; poultry processing; stainless steel;
D O I
10.1093/ps/79.12.1839
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Three common finishing treatments of stainless steel that are used for equipment during poultry processing were tested for resistance to bacterial contamination. Methods were developed to measure attached bacteria and to identify factors that make surface finishes susceptible or resistant to bacterial attachment and biofilm formation. Samples of the treated surfaces (sand-blasted, sanded, and electropolished) were exposed to natural bacterial populations from chicken carcass rinses to allow growth of bacteria and development of biofilms on the surfaces. The kinetics of bacterial growth during surface exposure was followed by UV-visible spectrophotometry, and counts of bacteria and early biofilm formation were measured following scanning electron microscopy (SEM). The surface morphology of the samples was analyzed by atomic force microscopy (AFM) with samples from each of the batches of treatments used in the SEM studies. Relative differences in the surface morphology, including fractal dimensions, Z ranges, roughness, and other measurements corresponded by treatment with the differences in reduction of bacterial counts shown by SEM. The surface types varied in affinity for bacteria, and both physical and electrochemical treatments improved resistance of stainless steel to bacterial attachment. Electropolished stainless steel was the least rough surface and showed significantly fewer bacterial cells and beginning biofilm formations than the other treated surfaces. Food safety could be improved if bacterial populations could be reduced during processing by increasing the use of materials that are resistant to bacterial contamination. These findings will aid equipment manufacturers and processors in selecting materials and finishes that are most resistant to bacteria and biofilm formation.
引用
收藏
页码:1839 / 1845
页数:7
相关论文
共 50 条
  • [1] Comparison of scanning electron and atomic force microscopy of surface finishes on stainless steel that reduce bacterial attachment
    Arnold, J.W.
    Bailey, G.W.
    Scanning, 2000, 22 (02) : 115 - 117
  • [2] A Nanoengineered Stainless Steel Surface to Combat Bacterial Attachment and Biofilm Formation
    Ban, Ga-Hee
    Li, Yong
    Wall, Marisa M.
    Jun, Soojin
    FOODS, 2020, 9 (11)
  • [3] Effects of corrosive treatment on stainless steel surface finishes and bacterial attachment
    Arnold, JW
    Suzuki, O
    TRANSACTIONS OF THE ASAE, 2003, 46 (06): : 1595 - 1602
  • [4] Effects of corrosive treatment on stainless steel surface finishes and bacterial attachment
    Arnold, J.W.
    Suzuki, O.
    Transactions of the American Society of Agricultural Engineers, 2003, 46 (06): : 1595 - 1602
  • [5] Bacterial attachment and biofilm formation on stainless steel surface and their in vitro inhibition by marine fungal extracts
    Mahyudin, Nor Ainy
    Daud, Noor Ifatul Hanim Mat
    Ab Rashid, Nor-Khaizura Mahmud
    Muhialdin, Belal J.
    Saari, Nazamid
    Noordin, Wan Norhana
    JOURNAL OF FOOD SAFETY, 2018, 38 (03)
  • [6] Bacterial Attachment and Biofilm Formation on Antimicrobial Sealants and Stainless Steel Surfaces
    Ciolacu, Luminita
    Zand, Elena
    Negrau, Carmen
    Jaeger, Henry
    FOODS, 2022, 11 (19)
  • [7] Atomic force microscopy and scanning electron microscopy study of MgO(110) surface faceting
    Giese, DR
    Lamelas, FJ
    Owen, HA
    Plass, R
    Gajdardziska-Josifovska, H
    SURFACE SCIENCE, 2000, 457 (03) : 326 - 336
  • [8] Comparative studies of bacterial biofilms on steel surfaces using atomic force microscopy and environmental scanning electron microscopy
    Beech, IB
    Cheung, CWS
    Johnson, DB
    Smith, JR
    BIOFOULING, 1996, 10 (1-3) : 65 - &
  • [9] SCANNING ELECTRON-MICROSCOPY STUDY OF STAINLESS-STEEL FINISHES USED IN FOOD-PROCESSING EQUIPMENT
    STONE, LS
    ZOTTOLA, EA
    FOOD TECHNOLOGY, 1985, 39 (05) : 110 - &
  • [10] Magnesium oxide (110) surface morphology study with atomic force microscopy and scanning electron microscopy
    Giese, DR
    Lamelas, FJ
    Owen, HA
    Gajdardziska-Josifovska, M
    SCANNING, 1999, 21 (02) : 73 - 74