Numerical investigation on the factors influencing the temperature distribution of photovoltaic/thermal (PVT) evaporator/condenser for heat pump systems

被引:27
作者
Bisengimana, Emmanuel [1 ]
Zhou, Jinzhi [1 ]
Binama, Maxime [2 ]
Yuan, Yanping [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Chengdu, Sichuan, Peoples R China
[2] Hohai Univ, Coll Water Conservancy & Hydropower Engn, Nanjing 210098, Peoples R China
基金
中国博士后科学基金;
关键词
Heat pump; PVT evaporator; Condenser; Efficiency factor; Temperature distribution; PERFORMANCE ANALYSIS; WATER-HEATER; SIMULATION; OPTIMIZATION; DESIGN;
D O I
10.1016/j.renene.2022.05.154
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Due to a high solar energy utilizing efficiency, Direct-expansion Solar-Assisted Heat Pump (DX SAHP) system has been a research hotspot for many years, especially for the system using PV/T module as the evaporator. The heat transfer throughout the PVT evaporator is an important factor for either electrical or thermal performance. We have developed and analyzed numerically the temperature distribution of a multi-source PVT heat exchanger of serpentine shape to fit a function as evaporator/condenser for Direct-expansion Photovoltaic/Thermal-Heat Pump (DX PVTHP) system. The suitability of the developed model was based on the calculated results of the efficiency factor and simulated results of temperatures of heat exchanger and working fluid as well the working fluid pressure drop. During the numerical simulations, we have considered different temperature influencing factors such as the refrigerant and refrigerant flow rate, spacing between the adjacent tubes of the heat exchanger, backside convection and radiation effect and finned heat exchanger. Simulated results showed that the serpentine PVT heat exchanger with fins and small space between tubes (62.5 mm) at 0.02 kg/s flow rate could achieve better results in terms of uniform temperature distribution, smaller fluid pressure drop (0.078 bar) and the highest efficiency factor (0.9873) which make it recommended as the best option for suitable evaporator/ condenser. The average PV temperature reached by cooled and uncooled PVT evaporator at 0.02 kg/s flow rate was 47.81 & DEG;C and 71.11 & DEG;C, respectively. It was 40.99 & DEG;C and 37.07 & DEG;C at the flow rate of 0.035 kg/s and 0.05 kg/s, respectively, and 44.44 & DEG;C for PVT evaporator with smaller space between tubes at 0.02 kg/s. The average PV temperature reached by the PVT evaporator with fins was 40.734 & DEG;C at the flow rate of 0.02 kg/s while it was 53.956 & DEG;C when the unit is insulated. (c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:885 / 901
页数:17
相关论文
共 25 条
  • [1] [Anonymous], 2019, GLOBAL ENERGY TRANSF
  • [2] Performance analysis of a novel air source hybrid solar assisted heat pump
    Cai, Jingyong
    Li, Zhouhang
    Ji, Jie
    Zhou, Fan
    [J]. RENEWABLE ENERGY, 2019, 139 : 1133 - 1145
  • [3] A novel PV/T-air dual source heat pump water heater system: Dynamic simulation and performance characterization
    Cai, Jingyong
    Ji, Jie
    Wang, Yunyun
    Zhou, Fan
    Yu, Bendong
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2017, 148 : 635 - 645
  • [4] Simulation and optimization of a hybrid unglazed solar photovoltaic-thermal collector and heat pump system with two storage tanks
    Dannemand, Mark
    Sifnaios, Ioannis
    Tian, Zhiyong
    Furbo, Simon
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 206 (206)
  • [5] Analysis and optimization of a heat pump system coupled to an installation of PVT panels and a seasonal storage tank on an educational building
    Del Amo, A.
    Martinez-Gracia, A.
    Pintanel, T.
    Bayod-Rujula, A. A.
    Torne, S.
    [J]. ENERGY AND BUILDINGS, 2020, 226
  • [6] Experimental study of a photovoltaic solar-assisted heat-pump/heat-pipe system
    Fu, H. D.
    Pei, G.
    Ji, J.
    Long, H.
    Zhang, T.
    Chow, T. T.
    [J]. APPLIED THERMAL ENGINEERING, 2012, 40 : 343 - 350
  • [7] Solar heating by radiant floor: Experimental results and emission reduction obtained with a micro photovoltaic-heat pump system
    Izquierdo, M.
    de Agustin-Camacho, P.
    [J]. APPLIED ENERGY, 2015, 147 : 297 - 307
  • [8] Experimental performance analysis of a direct-expansion solar-assisted heat pump water heater with R134a in summer
    Kong, Xiangqiang
    Sun, Penglong
    Dong, Shandong
    Jiang, Kailin
    Li, Ying
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 91 : 12 - 19
  • [9] Study on a direct-expansion solar-assisted heat pump water heating system
    Kuang, YH
    Sumathy, K
    Wang, RZ
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (05) : 531 - 548
  • [10] Operational performance study on a photovoltaic loop heat pipe/solar assisted heat pump water heating system
    Li, Hong
    Sun, Yue
    [J]. ENERGY AND BUILDINGS, 2018, 158 : 861 - 872