SBF assays, direct and indirect cell culture tests to evaluate the biological performance of bioglasses and bioglass-based composites: Three paradigmatic cases

被引:43
作者
Bellucci, Devis [1 ]
Salvatori, Roberta [2 ]
Anesi, Alexandre [2 ]
Chiarini, Luigi [2 ]
Cannillo, Valeria [1 ]
机构
[1] Univ Modena & Reggio Emilia, Dipartimento Ingn Enzo Ferrari, Consorzio Interuniv Nazl Sci & Tecnol Mat INSTM, Unite Ric, Via P Vivarelli 10, I-41125 Modena, Italy
[2] Univ Modena & Reggio Emilia, Dipartimento Sci Med Chirurg Matemoinfantili & Ad, Lab Biomat, Via Campi 213-A, I-41125 Modena, Italy
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2019年 / 96卷
关键词
Bioactive glasses; Composites; Bioactivity; Cytotoxicity tests; GLASS-CERAMIC SCAFFOLDS; BONE-GROWTH BEHAVIOR; BIOACTIVE GLASS; MECHANICAL-PROPERTIES; SURFACE-ROUGHNESS; 45S5; BIOGLASS; NEUTRAL RED; HYDROXYAPATITE; SUBSTITUTES; GRAFT;
D O I
10.1016/j.msec.2018.12.006
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A novel bioglass composition (BGMS10), containing strontium and magnesium and characterized by an ultra-high crystallization temperature, is here employed for the first time to produce different composites with the addition of specific amounts of hydroxyapatite. After an investigation of the samples' bioactivity in vitro in a simulated body fluid solution (SBF) - according to a widely used protocol -, the biocompatibility of the new materials was tested with respect to murine fibroblasts both by direct and indirect tests, in order to evaluate possible cytotoxic effects of the materials' eluates. Although none of the samples were cytotoxic and their bioactivity in SBF increased with the increasing amount of the glass in the composite, thus showing the best performance in the case of pure BGMS10 glass, the findings of the biological investigation did not confirm those arising from the SBF assay. Surprisingly, while the composites with the lowest glass amount showed an enhanced biocompatibility in direct tests, on the contrary their biological responsiveness is typically lower in the indirect ones, based on filtered materials' extracts. This fact could be ascribed to the high release of particulate from the composites, which are more porous than the glassy samples: in fact, such pronounced dissolution may affect both the cell viability and the absorbance readings used in the colorimetric assays. The pure BGMS10 glass showed the best biological response only in the cell proliferation test (which is an indirect contact test), being able to stimulate cell proliferation in particular after 24 h. For these reasons, when considering bioactive glasses and bioglass-based composites, the results of direct cell culture assays should be integrated with those obtained by indirect ones, while the findings regarding the in vitro bioactivity in SBF should be interpreted with great care.
引用
收藏
页码:757 / 764
页数:8
相关论文
共 61 条
  • [1] Microstructure and in vitro behaviour of 45S5 bioglass coatings deposited by high velocity suspension flame spraying (HVSFS)
    Altomare, L.
    Bellucci, D.
    Bolelli, G.
    Bonferroni, B.
    Cannillo, V.
    De Nardo, L.
    Gadow, R.
    Killinger, A.
    Lusvarghi, L.
    Sola, A.
    Stiegler, N.
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2011, 22 (05) : 1303 - 1319
  • [2] [Anonymous], 2007, 1099312 INT STAND
  • [3] [Anonymous], 2009, 109935 INT STAND
  • [4] Bioactive glass-based composites for the production of dense sintered bodies and porous scaffolds
    Bellucci, D.
    Sola, A.
    Cannillo, V.
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (04): : 2138 - 2151
  • [5] An Overview of The Effects of Thermal Processing on Bioactive Glasses
    Bellucci, D.
    Cannillo, V.
    Sola, A.
    [J]. SCIENCE OF SINTERING, 2010, 42 (03) : 307 - 320
  • [6] Bellucci D., 2018, BIOMED GLASSES, V4, P21, DOI [10.1515/bglass-2018-0003, DOI 10.1515/bglass-2018-0003]
  • [7] A novel bioactive glass containing strontium and magnesium with ultra-high crystallization temperature
    Bellucci, Devis
    Cannillo, Valeria
    [J]. MATERIALS LETTERS, 2018, 213 : 67 - 70
  • [8] A comparative in vivo evaluation of bioactive glasses and bioactive glass-based composites for bone tissue repair
    Bellucci, Devis
    Anesi, Alexandre
    Salvatori, Roberta
    Chiarini, Luigi
    Cannillo, Valeria
    [J]. MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 79 : 286 - 295
  • [9] Role of magnesium oxide and strontium oxide as modifiers in silicate-based bioactive glasses: Effects on thermal behaviour, mechanical properties and in-vitro bioactivity
    Bellucci, Devis
    Sola, Antonella
    Salvatori, Roberta
    Anesi, Alexandre
    Chiarini, Luigi
    Cannillo, Valeria
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 72 : 566 - 575
  • [10] Hydroxyapatite and tricalcium phosphate composites with bioactive glass as second phase: State of the art and current applications
    Bellucci, Devis
    Sola, Antonella
    Cannillo, Valeria
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2016, 104 (04) : 1030 - 1056