Distance Protection of Lines Emanating From Full-Scale Converter-Interfaced Renewable Energy Power Plants-Part I: Problem Statement

被引:165
作者
Hooshyar, Ali [1 ]
Azzouz, Maher A. [1 ]
El-Saadany, Ehab F. [1 ]
机构
[1] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
关键词
Converter-interfaced renewable energy power plant (CIREPP); line distance relay; photovoltaic farm; type IV wind farm; WIND FARMS; REQUIREMENTS;
D O I
10.1109/TPWRD.2014.2369479
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fault ride-through (FRT) requirement of modern grid codes results in interactions between full-scale converter-interfaced renewable energy power plants (CIREPPs) and the protection systems of high-voltage transmission grids, which normally involve distance elements either as the primary or the backup relay. Such interactions are influenced by the CIREPPs' exclusive fault behavior, and have been left largely unnoticed in relaying literature. Part I of this paper develops a CIREPP model suitable for relaying studies, and highlights the CIREPP properties by which the protection system is endangered the most. Then, the operating scenarios leading to the malfunction of a distance relay that is located at a CIREPP substation and protects the adjacent line are unveiled. These scenarios include in-zone short circuits missed by the relay and incorrect tripping for out-of-zone faults, which would, in turn, neutralize FRT schemes implemented inside CIREPPs. The findings of this study also hold true for the ac lines emanating from voltage-sourced converter-based HVDC connections.
引用
收藏
页码:1770 / 1780
页数:11
相关论文
共 30 条
[1]  
[Anonymous], 2012, D90Plus line distance protection system
[2]  
[Anonymous], 2010, ORDINANCE SYSTEM SER
[3]  
[Anonymous], 2012, LINE DISTANCE PROTEC
[4]  
[Anonymous], 2013, ENTSO E DRAFT NETW C
[5]  
[Anonymous], 1994, US Patent, Patent No. 5325061
[6]   Model Validation for Wind Turbine Generator Models [J].
Asmine, Mohamed ;
Brochu, Jacques ;
Fortmann, Jens ;
Gagnon, Richard ;
Kazachkov, Yuriy ;
Langlois, Charles-Eric ;
Larose, Christian ;
Muljadi, Eduard ;
MacDowell, Jason ;
Pourbeik, Pouyan ;
Seman, Slavomir A. ;
Wiens, Kevin .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (03) :1769-1782
[7]  
Bollen M., 2011, INTEGRATION DISTRIBU, P299
[8]   Validation of Single- and Multiple-Machine Equivalents for Modeling Wind Power Plants [J].
Brochu, Jacques ;
Larose, Christian ;
Gagnon, Richard .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (02) :532-541
[9]   Low-voltage ride-through of a full converter wind turbine with permanent magnet generator [J].
Conroy, J. F. ;
Watson, R. .
IET RENEWABLE POWER GENERATION, 2007, 1 (03) :182-189
[10]  
ENTSO-E, 2013, ENTSO E NETW COD REQ