Comparison of hyperpolarized 3He MRI with Xe-enhanced computed tomography imaging for ventilation mapping of rat lung

被引:9
作者
Santyr, Giles E. [1 ,2 ,3 ]
Couch, Marcus J. [1 ,4 ]
Lam, Wilfred W. [5 ]
Ouriadov, Alexei [1 ]
Drangova, Maria [1 ,2 ,3 ]
McCormack, David G. [6 ]
Holdsworth, David W. [1 ,2 ,3 ]
机构
[1] Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Dept Med Imaging, London, ON, Canada
[4] Univ Western Ontario, Dept Phys & Astron, London, ON, Canada
[5] Sunnybrook Hlth Sci Ctr, Toronto, ON M4N 3M5, Canada
[6] London Hlth Sci Ctr, Div Respirol, London, ON, Canada
基金
加拿大健康研究院;
关键词
ventilation; lung; helium; MRI; xenon; computed tomography; REGIONAL VENTILATION; DIFFUSING-CAPACITY; PULMONARY-DISEASE; XENON; PERFUSION; SPECTROSCOPY; MODELS;
D O I
10.1002/nbm.1659
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Lung ventilation was mapped in five healthy Brown Norway rats (210-377 g) using both hyperpolarized He-3 MRI and Xe-enhanced computed tomography (Xe-CT) under similar ventilator conditions. Whole-lung measurements of ventilation r obtained with He-3 MRI were not significantly different from those obtained from Xe-CT (p = 0.1875 by Wilcoxon matched pairs test). The ventilation parameter r is defined as the fraction of refreshed gas per unit volume per breath. Regional ventilation was also measured in four regions of the lung using both methods. A two-tailed paired t-test was performed for each region, yielding p > 0.05 for all but the upper portion of the right lung. The distribution of regional ventilation was evaluated by calculating ventilation gradients in the superior/inferior (S/I) direction. The average S/I gradient obtained using the He-3 MRI method was found to be 0.17 +/- 0.04 cm(-1), whereas the average S/I gradient obtained using the Xe-CT method was found to be 0.016 +/- 0.005 cm(-1). In general, S/I ventilation gradients obtained from both methods were significantly different from each other (p = 0.0019 by two-tailed paired t-test). These regional differences in ventilation measurements may be caused by the manner in which the gas contrast agents distribute physiologically and/or by the imaging modality. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 27 条
[1]   Measurement of xenon diffusing capacity in the rat lung by hyperpolarized 129Xe MRI and dynamic spectroscopy in a single breath-hold [J].
Abdeen, Nishard ;
Cross, Albert ;
Cron, Gregory ;
White, Steven ;
Rand, Thomas ;
Miller, David ;
Santyr, Giles .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) :255-264
[2]   Pulmonary embolism: Comprehensive evaluation with MR ventilation and perfusion scanning with hyperpolarized helium-3, arterial Spin tagging, and contrast-enhanced MRA [J].
Altes, TA ;
Mai, VM ;
Munger, TM ;
Brookeman, JR ;
Hagspiel, KD .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (07) :999-1005
[3]   Differences in the time course of proximal and distal airway response to inhaled histamine studied by synchrotron radiation CT [J].
Bayat, S ;
Porra, L ;
Suhonen, H ;
Nemoz, C ;
Suortti, P ;
Sovijärvi, ARA .
JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (06) :1964-1973
[4]   In Vivo mouse imaging and spectroscopy in drug discovery [J].
Beckmann, Nicolau ;
Kneuer, Rainer ;
Gremlich, Hans-Ulrich ;
Karmouty-Quintana, Harry ;
Ble, Francois-Xavier ;
Mueller, Matthias .
NMR IN BIOMEDICINE, 2007, 20 (03) :154-185
[5]  
Brown Robert H, 2008, Proc Am Thorac Soc, V5, P591, DOI 10.1513/pats.200708-116ST
[6]   Differences in regional wash-in and wash-out time constants for xenon-CT ventilation studies [J].
Chon, D ;
Simon, BA ;
Beck, KC ;
Shikata, H ;
Saba, OI ;
Won, CH ;
Hoffman, EA .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2005, 148 (1-2) :65-83
[7]   3He diffusion MRI of the lung [J].
Conradi, MS ;
Yablonskiy, DA ;
Woods, JC ;
Gierada, DS ;
Jacob, RE ;
Chang, YLV ;
Choong, CK ;
Sukstanskii, AL ;
Tanoli, T ;
Lefrak, SS ;
Cooper, JD .
ACADEMIC RADIOLOGY, 2005, 12 (11) :1406-1413
[8]   Study of the Variability in Upper and Lower Airway Morphology in Sprague-Dawley Rats Using Modern Micro-CT Scan-Based Segmentation Techniques [J].
De Backer, Jan W. ;
Vos, Wim G. ;
Burnell, Patricia ;
Verhulst, Stijn L. ;
Salmon, Phil ;
De Clerck, Nora ;
De Backer, Wilfried .
ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2009, 292 (05) :720-727
[9]   Quantitative measurement of regional lung ventilation using 3He MRI [J].
Deninger, AJ ;
Månsson, S ;
Petersson, JS ;
Pettersson, G ;
Magnusson, P ;
Svensson, J ;
Fridlund, B ;
Hansson, G ;
Erjefeldt, I ;
Wollmer, P ;
Golman, K .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :223-232
[10]   Imaging techniques for small animal models of pulmonary disease: MR microscopy [J].
Driehuys, Bastiaan ;
Hedlund, Laurence W. .
TOXICOLOGIC PATHOLOGY, 2007, 35 (01) :49-58