Evaluation of the dynamic conformal arc therapy in comparison to intensity-modulated radiation therapy in prostate, brain, head-and-neck and spine tumors

被引:12
作者
Morales-Paliza, Manuel A. [1 ]
Coffey, Charles W. [1 ]
Ding, George X. [1 ]
机构
[1] Vanderbilt Univ, Dept Radiat Oncol, Med Ctr, Nashville, TN 37232 USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2011年 / 12卷 / 02期
关键词
dynamic conformal arc therapy; intensity-modulated radiation therapy; dose validation; treatment time; external-beam radiation therapy; IMRT DOSE DISTRIBUTIONS; VOLUME HISTOGRAMS; CANCER; RADIOTHERAPY; TOXICITY; IMPACT; MOTION; DELIVERY;
D O I
10.1120/jacmp.v12i2.3197
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate dynamic conformal arc therapy (DAT) dose distribution and clinical applicability in comparison to intensity-modulated radiotherapy (IMRT) in different types of tumors and locations, twelve patients with prostate cancer with no node involvement and three patients with single tumors in the pituitary, in the neck and in the thoracic spinal region treated with IMRT, were retrospectively planned with DAT using Eclipse (V8.1). The prostate cases were also planned with three-dimensional conformal radiation therapy (3DCRT). Dose distributions were evaluated through comparisons of dose-volumetric histograms and in-house IMRT protocol constraints, as well as validated via ion chamber array measurements. DAT plans for prostate showed a statistically comparable achievement of tumor conformity and dose sparing for bladder and rectum when compared to IMRT. Dose on femoral heads were similar to those achieved using 3DCRT. DAT could be planned with similar results to those obtained in IMRT for the dose constraints of the defined structures by using a 360 arc for the brain lesion and several arcs including noncoplanar ones for the head-and-neck and spinal tumors. Experimental validation of the calculated dose distributions via gamma analysis of composite distributions for DAT provided that more than 95% of the pixels satisfy the criteria 3 mm-3%, which was similar to that of IMRT. The average number of monitor units was approximately five times lower than IMRT. In conclusion, DAT is capable of providing conformal dose distributions to the targets accomplishing many of the IMRT dose constraints simultaneously. Experimental dose-validation accuracy, ease of planning and reduced treatment times make DAT both acceptable and attractive for clinical use.
引用
收藏
页码:5 / 19
页数:15
相关论文
共 26 条
[1]   Single-Arc IMRT? [J].
Bortfeld, Thomas ;
Webb, Steve .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (01) :N9-N20
[2]   A feasibility study of image-guided hypofractionated conformal arc therapy for inoperable patients with localized non-smatt cell lung cancer [J].
Bral, Samuel ;
Van Parijs, Hitde ;
Soete, Guy ;
Linthout, Nadine ;
Van Moorter, Lutgard ;
Verellen, Dirk ;
Storme, Guy .
RADIOTHERAPY AND ONCOLOGY, 2007, 84 (03) :252-256
[3]   Individualized planning target volumes for intrafraction motion during hypofractionated intensity-modulated radiotherapy boost for prostate cancer [J].
Cheung, P ;
Sixel, K ;
Morton, G ;
Loblaw, DA ;
Tirona, R ;
Pang, G ;
Choo, R ;
Szumacher, E ;
DeBoer, G ;
Pignol, JP .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (02) :418-425
[4]   A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation [J].
Depuydt, T ;
Van Esch, A ;
Huyskens, DP .
RADIOTHERAPY AND ONCOLOGY, 2002, 62 (03) :309-319
[5]   The effects of tumor motion on planning and delivery of respiratory-gated IMRT [J].
Hugo, GD ;
Agazaryan, N ;
Solberg, TD .
MEDICAL PHYSICS, 2003, 30 (06) :1052-1066
[6]   Biological-effective versus conventional dose volume histograms correlated with late genitourinary and gastrointestinal toxicity after external beam radiotherapy for prostate cancer: a matched pair analysis [J].
Jani, AB ;
Hand, CM ;
Pelizzari, CA ;
Roeske, JC ;
Krauz, L ;
Vijayakumar, S .
BMC CANCER, 2003, 3 (1)
[7]   Dose escalation for prostate cancer using the three-dimensional conformal dynamic ARC technique: Analysis of 542 consecutive patients [J].
Jereczek-Fossa, Barbara A. ;
Vavassori, Andrea ;
Fodor, Cristiana ;
Santoro, Luigi ;
Zerini, Dario ;
Cattani, Federica ;
Garibaldi, Cristina ;
Cambria, Raffaella ;
Fodor, Andrei ;
Boboc, Genoveva Ionela ;
Vitolo, Viviana ;
Ivaldi, Giovanni Battista ;
Musi, Gennaro ;
de Cobelli, Ottavio ;
Orecchia, Roberto .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (03) :784-794
[8]   SOONER OR LATER? OUTCOME ANALYSIS OF 431 PROSTATE CANCER PATIENTS TREATED WITH POSTOPERATIVE OR SALVAGE RADIOTHERAPY [J].
Jereczek-Fossa, Barbara A. ;
Zerini, Dario ;
Vavassori, Andrea ;
Fodor, Cristiana ;
Santoro, Luigi ;
Minissale, Antonio ;
Cambria, Raffaella ;
Cattani, Federica ;
Garibaldi, Cristina ;
Serafini, Flavia ;
Matei, Victor Deliu ;
De Cobelli, Ottavio ;
Orecchia, Roberto .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (01) :115-125
[9]   Dose distribution in 3-dimensional conformal radiotherapy for prostate cancer: Comparison of two treatment techniques (six coplanar fields and two dynamic arcs) [J].
Jereczek-Fossa, Barbara Alicja ;
Cattani, Federica ;
D'Onofrio, Alberto ;
Cambria, Raffaella ;
Kowalczyk, Anna ;
Corallo, Anna ;
Vavassori, Andrea ;
Zerini, Dario ;
Ivaldi, Giovanni Battista ;
DeCobelli, Ottavio ;
Orecchia, Roberto .
RADIOTHERAPY AND ONCOLOGY, 2006, 81 (03) :294-302
[10]   The use of spatial dose gradients and probability density function to evaluate the effect of internal organ motion for prostate IMRT treatment planning [J].
Jiang, Runqing ;
Barnett, Rob B. ;
Chow, James C. L. ;
Chen, Jeff Z. Y. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (05) :1469-1484