Automated skull tracking for the CyberKnife® image-guided radiosurgery system

被引:8
作者
Fu, DS [1 ]
Kuduvalli, G [1 ]
Mitrovic, V [1 ]
Main, W [1 ]
Thomson, L [1 ]
机构
[1] Accuray Inc, Sunnyvale, CA 94089 USA
来源
MEDICAL IMAGING 2005: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, PTS 1 AND 2 | 2005年 / 5744卷
关键词
image-guided radiosurgery; 2-D/3-D registration; CT images; X-ray images; digitally reconstructed radiograph (DRR); tracking accuracy; targeting accuracy;
D O I
10.1117/12.594984
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed an automated skull tracking method to perform near real-time patient alignment and position correction during CyberKnife (R) image-guided intracranial radiosurgery. Digitally reconstructed radiographs (DRRs) are first generated offline from a CT study before treatment, and are used as reference images for the patient position. Two orthogonal projection X-ray images are then acquired at the time of patient alignment or treatment. Multi-phase registration is used to register the DRRs with the X-ray images. The registration in each projection is carried out independently; the results are then combined and converted to a 3-D rigid transformation. The in-plane transformation and the out-of-plane rotations are estimated using different search methods including multi-resolution matching, steepest descent minimization and one-dimensional search. Two similarity measure methods, optimized pattern intensity and sum of squared difference (SSD), are applied at different search phases to optimize both accuracy and computation speed. Experiments on an anthropomorphic skull phantom showed that the tracking accuracy (RMS error) is better than 0.3 mm for each translation and better than 0.3 degree for each rotation, and the targeting accuracy (clinically relevant accuracy) tested with the CyberKnife system is better than 1 mm. The computation time required for the tracking algorithm is within a few seconds.
引用
收藏
页码:366 / 377
页数:12
相关论文
共 20 条
[1]   Image-guided robotic radiosurgery [J].
Adler, JR ;
Murphy, MJ ;
Chang, SD ;
Hancock, SL .
NEUROSURGERY, 1999, 44 (06) :1299-1306
[2]   Patient setup error measurement using 3D intensity-based image registration techniques [J].
Clippe, S ;
Sarrut, D ;
Malet, C ;
Miguet, S ;
Ginestet, C ;
Carrie, C .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (01) :259-265
[3]   Anatomy-based registration of CT-scan and intraoperative X-ray images for guiding a surgical robot [J].
Guéziec, A ;
Kazanzides, P ;
Williamson, B ;
Taylor, RH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :715-728
[4]  
Hamadeh A, 1998, Comput Aided Surg, V3, P11, DOI 10.3109/10929089809148123
[5]   Intensity-based 2-D-3-D registration of cerebral angiograms [J].
Hipwell, JH ;
Penney, GP ;
McLaughlin, RA ;
Rhode, K ;
Summers, P ;
Cox, TC ;
Byrne, JV ;
Noble, JA ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) :1417-1426
[6]   A feasibility study of mutual information based setup error estimation for radiotherapy [J].
Kim, J ;
Fessler, JA ;
Lam, KL ;
Balter, JM ;
Ten Haken, RK .
MEDICAL PHYSICS, 2001, 28 (12) :2507-2517
[7]   Gamma knife radiosurgery for benign cavernous sinus tumors: Quantitative analysis of treatment outcomes [J].
Kuo, JS ;
Chen, JCT ;
Yu, C ;
Zelman, V ;
Giannotta, SL ;
Petrovich, Z ;
MacPherson, D ;
Apuzzo, MLJ .
NEUROSURGERY, 2004, 54 (06) :1385-1393
[8]  
LaRose D. A., 2001, THESIS CARNEGIE MELL
[9]   RECOVERING THE POSITION AND ORIENTATION OF FREE-FORM OBJECTS FROM IMAGE CONTOURS USING 3D DISTANCE MAPS [J].
LAVALLEE, S ;
SZELISKI, R .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1995, 17 (04) :378-390
[10]  
LEMIEUX L, 1994, MED PHYS, V21