Parallel ZVS Converter with Series Connected Transformers

被引:0
作者
Lin, Bor-Ren [1 ]
Chiang, Huann-Keng [1 ]
Chen, Po-Li [1 ]
Cheng, Chih-Yuan [1 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Dept Elect Engn, Yunlin 640, Taiwan
来源
TENCON 2010: 2010 IEEE REGION 10 CONFERENCE | 2010年
关键词
series connected transformers; parallel converters; converters; ACTIVE-CLAMP; FLYBACK CONVERTERS; DESIGN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a parallel zero voltage switching (ZVS) dc-dc converter with series connected transformers. In order to increase output power, two transformers connected in series are used in the proposed converter. Two buck-type converters connected in parallel have the same switching devices. The primary windings of series connected transformers can achieve the balanced secondary winding currents. The current doubler rectifiers with ripple current cancellation are connected in parallel at the output side to reduce the current stress of the secondary winding. Thus the current ripple on the output capacitor is reduced and the size of output choke and output capacitor are reduced. Only two switches are used in the proposed circuit instead of four switches in the conventional parallel ZVS converter to achieve zero voltage switching and output current sharing. Therefore, the proposed converter has less power switches. The ZVS turn-on is implemented during the commutation stage of two complementary switches such that the switching losses and thermal stresses on the semiconductors are reduced. Experimental results for a 528W (48V/11A) prototype are presented to prove the theoretical analysis and circuit performance.
引用
收藏
页码:1829 / 1834
页数:6
相关论文
共 13 条
[1]  
CHEN Q, 1993, IEEE POWER ELECTRON, P749, DOI 10.1109/PESC.1993.472008
[2]   A high-efficiency soft-switched AC/DC converter with current-doubler synchronous rectification [J].
Chiu, HJ ;
Lin, LW .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2005, 52 (03) :709-718
[3]  
FARRINGTON R, 1990, IEEE POWER ELECTRON, P197, DOI 10.1109/PESC.1990.131189
[4]   High-efficiency active-clamp forward converter with transient current build-up (TCB) ZVS technique [J].
Lee, Sung-Sae ;
Choi, Seong-Wook ;
Moon, Gun-Woo .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (01) :310-318
[5]   Analysis, design and implementation of active clamp zero voltage switching converter with output ripple current cancellation [J].
Lin, B. -R. ;
Hsieh, F. -Y. ;
Wang, D. ;
Huang, K. .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2006, 153 (05) :653-663
[6]   Design and performance evaluation of low-voltage/high-current DC/DC on-board modules [J].
Panov, Y ;
Jovanovic, MM .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2001, 16 (01) :26-33
[7]   Active voltage clamp in flyback converters operating in CCM mode under wide load variation [J].
Papanikolaou, NP ;
Tatakis, EC .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (03) :632-640
[8]   Calculation of the resonant capacitor of the improved current-doubler-rectifier ZVS PWM full-bridge converter [J].
Ruan, XB ;
Wang, JG .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2004, 51 (02) :518-520
[9]   Analysis of a multiresonant forward converter based on nonideal coupling of the transformer [J].
Smith, TA ;
Dimitrijev, S .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (01) :111-120
[10]  
SUN N, 1993, IEEE POWER ELECTRON, P1116, DOI 10.1109/PESC.1993.472058