Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging

被引:46
作者
Chan, Tommy C. Y. [1 ,2 ]
Biswas, Sayantan [1 ]
Yu, Marco [1 ,3 ]
Jhanji, Vishal [1 ,2 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Hong Kong Eye Hosp, Hong Kong, Hong Kong, Peoples R China
[3] Hang Seng Management Coll, Dept Math & Stat, Hong Kong, Peoples R China
关键词
combined Placido-Scheimpflug imaging; keratoconus; repeatability; swept-source optical coherence tomography; SITU KERATOMILEUSIS EYES; ULTRASOUND PACHYMETRY; THICKNESS; REPEATABILITY; TOPOGRAPHY; SEGMENT; CAMERA; PHOTOGRAPHY; LIMITATIONS; SYSTEM;
D O I
10.1111/aos.13298
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PurposeThe aim of this study was to provide a comprehensive comparison of reliability of corneal topographic measurements in keratoconic eyes using swept-source optical coherence tomography (OCT) and a combined Placido-Scheimpflug imaging. MethodsA total of 30 eyes of 30 patients were included. The mean age was 31.28.4years. Two consecutive topographic measurements were obtained for one eye of each patient using swept-source OCT (CASIA) and combined Placido-Scheimpflug imaging (TMS-5). Test-retest reliabilityof CASIA and TMS-5 measurements including central corneal thickness (CCT) and thinnest corneal thickness (TCT), keratometry at steep (Ks)andflat (Kf) axes, average keratometry (Avg K), cylinder, and, best-fit spheres (BFS) of the anterior and posterior corneal surfaces were evaluated. ResultsThere was no systematic or scaling bias in any parameter in both devices. Systematic differences between CASIA and TMS-5 were found in posterior corneal Kf, Avg K and BFS, CCT and TCT (p0.002); scaling differences between CASIA and TMS-5 were also found in CCT and TCT (p0.002). Both machines illustrated adequate reliability. Intraclass correlation coefficients (ICC) 0.952 was recorded for all parameters measured with CASIA and ICC0.914 was recorded for all parameters on TMS-5. CASIA showed significantly higher ICCs in CCT and TCT, and posterior corneal BFS (p<0.001). ConclusionsThis study showed significant differences in posterior corneal surface and corneal thickness measurements between swept-source OCT and combined Placido-Scheimpflug imaging in eyes with keratoconus. Swept-source OCT might be preferred over Placido-Scheimpflug imaging owing to better repeatability of measurements.
引用
收藏
页码:E486 / E494
页数:9
相关论文
共 26 条
[1]   Evaluation of Pachymetric Measurements with Scheimpflug Photography-Based System and Optical Coherence Tomography Pachymetry at Different Stages of Keratoconus [J].
Akcay, Betul Ilkay Sezgin ;
Ozgurhan, Engin Bilge ;
Bozkurt, Ercument ;
Kurt, Tugba ;
Yildirim, Yusuf ;
Cosar, Mediha Gulen ;
Yildirim, Aydin ;
Akkan, Julide Canan Umurhan ;
Demirok, Ahmet .
JOURNAL OF OPHTHALMOLOGY, 2014, 2014
[2]   Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography [J].
Amano, S ;
Honda, N ;
Amano, Y ;
Yamagami, S ;
Miyai, T ;
Samejima, T ;
Ogata, M ;
Miyata, K .
OPHTHALMOLOGY, 2006, 113 (06) :937-941
[3]   Statistics notes: Measurement error proportional to the mean .23. [J].
Bland, JM ;
Altman, DG .
BRITISH MEDICAL JOURNAL, 1996, 313 (7049) :106-106
[4]   Orbscan computerized topography: Attributes, applications, and limitations [J].
Cairns, G ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :205-220
[5]   Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik [J].
Chan, Tommy C. Y. ;
Biswas, Sayantan ;
Yu, Marco ;
Jhanji, Vishal .
MEDICINE, 2015, 94 (30)
[6]   Corneal Thickness in Keratoconus Comparing Optical, Ultrasound, and Optical Coherence Tomography Pachymetry [J].
Dutta, Debarun ;
Rao, Harsha L. ;
Addepalli, Uday K. ;
Vaddavalli, Pravin K. .
OPHTHALMOLOGY, 2013, 120 (03) :457-463
[7]   Comparison of three-dimensional optical coherence tomography and combining a rotating Scheimpflug camera with a Placido topography system for forme fruste keratoconus diagnosis [J].
Fukuda, Shinichi ;
Beheregaray, Simone ;
Hoshi, Sujin ;
Yamanari, Masahiro ;
Lim, Yiheng ;
Hiraoka, Takahiro ;
Yasuno, Yoshiaki ;
Oshika, Tetsuro .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (12) :1554-1559
[8]   Assessment of central corneal thickness in normal, keratoconus, and post-laser in situ keratomileusis eyes using Scheimpflug imaging, spectral domain optical coherence tomography, and ultrasound pachymetry [J].
Grewal, Dilraj S. ;
Brar, Gagandeep S. ;
Grewal, Satinder P. S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06) :954-964
[9]   Effect of keratoconus grades on repeatability of keratometry readings: Comparison of 5 devices [J].
Hashemi, Hassan ;
Yekta, Abbasali ;
Khabazkhoob, Mehdi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) :1065-1072
[10]   A Comparison between Scheimpflug Imaging and Optical Coherence Tomography in Measuring Corneal Thickness [J].
Huang, Jinhai ;
Ding, Xixia ;
Savini, Giacomo ;
Pan, Chao ;
Feng, Yifan ;
Cheng, Dan ;
Hua, Yanjun ;
Hu, Xiuli ;
Wang, Qinmei .
OPHTHALMOLOGY, 2013, 120 (10) :1951-1958