Effect of phase change material wall on natural convection heat transfer inside an air filled enclosure

被引:22
作者
Labihi, Abdelouhab [1 ]
Aitlahbib, Faical [1 ]
Chehouani, Hassan [1 ]
Benhamou, Brahim [2 ,3 ]
Ouikhalfan, Mohammed [1 ]
Croitoru, Cristiana [4 ]
Nastase, Ilinca [4 ]
机构
[1] Cadi Ayyad Univ, Fac Sci & Tech, LP2M2E, Marrakech, Morocco
[2] Cadi Ayyad Univ, Natl Ctr Studies & Res Water & Energy CNEREE, Lab Renewable Energies & Energy Efficiency EnR2E, Marrakech, Morocco
[3] Cadi Ayyad Univ, Fac Sci Semlalia, LMFE, Energy Proc Res Grp, Marrakech, Morocco
[4] Tech Univ Civil Engn Bucharest, Bldg Serv Dept, Bucharest, Romania
关键词
Energy management; Phase change material; Natural convection; Solidification phase front; Active wall; Heat storage; PCM; PERFORMANCE; STORAGE; FLOW; SYSTEM; UNIT;
D O I
10.1016/j.applthermaleng.2017.07.112
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with a numerical and experimental study of a square enclosure filled with air and differentially heated. The heated vertical wall of the enclosure contains a 1 cm thickness layer of a phase change material (PCM), whereas the opposite one is cooled. The dimensions of the experimental air cavity are 10 cm x 10 cm with a width of 10 cm. The PCM layer, initially molten, is discharged in the air within the cavity. Temperature measurements were performed inside the air cavity as well as the PCM and the PCM/air interface during the charging and discharging processes. A numerical model based on the coupled Navier-Stokes and energy equations for the air inside the cavity and the PCM layer was developed to examine the perturbation of the phase change on heat transfer at the PCM/air interface. The results showed a notable disagreement between the calculated and measured temperature in the cavity and PCM, when the density change during the solidification process has not been taken into account. A new approach based on volume contraction during solidification has been proposed and successfully tested to overcome this issue. Moreover, the simulations demonstrated that the heat transfer in the cavity is affected significantly when the phase change occurs. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:305 / 314
页数:10
相关论文
共 24 条
[1]   Numerical study of heat transfer inside a Keeping Warm System (KWS) incorporating phase change material [J].
Aitlahbib, Faical ;
Chehouani, Hassan .
APPLIED THERMAL ENGINEERING, 2015, 75 :73-85
[2]  
[Anonymous], 2000, CONTEMP PHYS, V41, P437
[3]  
[Anonymous], THESIS
[4]  
[Anonymous], 2007, MOL PHYS INT J INTER, DOI DOI 10.1080/0026897042000275017
[5]  
[Anonymous], 2001, ASHRAE fundamentals handbook
[6]  
Chehouani H, 1999, THESIS
[7]   Numerical study on the thermal performance of a ventilated facade with PCM [J].
de Gracia, Alvaro ;
Navarro, Lidia ;
Castell, Albert ;
Cabeza, Luisa F. .
APPLIED THERMAL ENGINEERING, 2013, 61 (02) :372-380
[8]   A correlation of the convective heat transfer coefficient between an air flow and a phase change material plate [J].
de Gracia, Alvaro ;
David, Damien ;
Castell, Albert ;
Cabeza, Luisa F. ;
Virgone, Joseph .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :1245-1254
[9]  
ECKERT E.R. G., 1961, Int. J. Heat Mass Transfer, V2, P106, DOI 10.1016/0017-9310(61)90019-9
[10]   A review of performance enhancement of PCM based latent heat storage system within the context of materials, thermal stability and compatibility [J].
Khan, Zakir ;
Khan, Zulfiqar ;
Ghafoor, Abdul .
ENERGY CONVERSION AND MANAGEMENT, 2016, 115 :132-158