EFFICIENCY CALIBRATION FOR ENVIRONMENTAL GAMMA SPECTROMETRY USING GATE

被引:1
作者
Alrefae, Tareq [1 ]
机构
[1] Kuwait Univ, Dept Phys, Fac Sci, Khaldia, Kuwait
来源
HEALTH PHYSICS | 2016年 / 110卷 / 06期
关键词
detector; germanium; Monte Carlo; radiation; background; spectroscopy; gamma; MONTE-CARLO CALCULATIONS; RAY SPECTROMETRY; ALMERA NETWORK; SINGLE-ESCAPE; GEANT4; CODE; SIMULATION; RADIOACTIVITY; STANDARD; DETECTOR; SPECTRA;
D O I
10.1097/HP.0000000000000498
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work investigated the utility of performing efficiency calibration for environmental gamma spectrometry using the Monte Carlo based, free of charge GATE toolbox. The validity of this approach was tested by comparing output efficiency values of an in-house developed GATE-based program with experimental measurements covering various geometries and primary photon energies. The results of this comparison revealed relative deviations within +/- 20%, thus validating the employed computational approach. Moreover, the GATE-based method was able to predict quantities that are generally difficult to measure experimentally, such as the number of interactions preceding full energy absorption. These computationally obtained predictions were found to be in agreement with theory.
引用
收藏
页码:588 / 597
页数:10
相关论文
共 34 条
  • [1] Adams KJ, 1996, P SPIE INT SOC OPT E, V2867, P418
  • [2] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [3] GAMMA SPECTROMETRY EFFICIENCY CALIBRATION USING MONTE CARLO METHODS TO MEASURE RADIOACTIVITY OF 137CS IN FOOD SAMPLES
    Alrefae, T.
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 162 (03) : 220 - 223
  • [4] GEANT4 CALIBRATION OF GAMMA SPECTROMETRY EFFICIENCY FOR MEASUREMENTS OF AIRBORNE RADIOACTIVITY ON FILTER PAPER
    Alrefae, Tareq
    [J]. HEALTH PHYSICS, 2014, 107 (05): : 435 - 441
  • [5] PENELOPE - AN ALGORITHM FOR MONTE-CARLO SIMULATION OF THE PENETRATION AND ENERGY-LOSS OF ELECTRONS AND POSITRONS IN MATTER
    BARO, J
    SEMPAU, J
    FERNANDEZVAREA, JM
    SALVAT, F
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 100 (01) : 31 - 46
  • [6] A soil sampling intercomparison exercise for the ALMERA network
    Belli, Maria
    de Zorzi, Paolo
    Sansone, Umberto
    Shakhashiro, Abduhlghani
    da Fonseca, Adelaide Gondin
    Trinkl, Alexander
    Benesch, Thomas
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2009, 100 (11) : 982 - 987
  • [7] A STANDARD TIMING BENCHMARK FOR EGS4 MONTE-CARLO CALCULATIONS
    BIELAJEW, AF
    ROGERS, DWO
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 303 - 304
  • [8] The FLUKA Code: Developments and Challenges for High Energy and Medical Applications
    Boehlen, T. T.
    Cerutti, F.
    Chin, M. P. W.
    Fosso, A.
    Ferrari, A.
    Ortega, P. G.
    Mairani, A.
    Sala, P. R.
    Smirnov, G.
    Vlachoudisl, V.
    [J]. NUCLEAR DATA SHEETS, 2014, 120 : 211 - 214
  • [9] A GUI application for creating macrofiles in GATE
    Boukis, S.
    Sakellios, N.
    Loudos, G.
    Nikita, K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02) : 378 - 380
  • [10] Capell BM, 1997, PROCEEDINGS OF THE TOPICAL MEETING ON CRITICALITY SAFETY CHALLENGES IN THE NEXT DECADE, P384