Characterisation of a micro-total analytical system for the determination of nitrite with spectrophotometric detection

被引:126
作者
Greenway, GM [1 ]
Haswell, SJ [1 ]
Petsul, PH [1 ]
机构
[1] Univ Hull, Dept Chem, Kingston Upon Hull HU6 7RX, N Humberside, England
关键词
micro flow injection analysis; nitrite; miniaturisation; mu TAS;
D O I
10.1016/S0003-2670(99)00047-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A micro-total analytical system (mu TAS) is described for the determination of nitrite based on its reaction with sulphanilamide to form the diazonium salt which when coupled with N-(1-naphthyl) ethylene diamine yields an azo dye whose absorbance was measured at 526 nm. The reaction took place in an etched glass manifold containing channels 302 mu m wide and 115 mu m deep in which electro-osmotic how was used to move the reagents. The absorbance of the product was measured in situ using a micro-spectrophotometric-fibre optic detection system. The electro-osmotic flow mixing characteristics of the reagents together with the production of the colorimetric complex have been investigated. in addition methods for obtaining sensitive detection in the micro-reactor are reported. Using the conditions established a linear calibration was obtained between 0 and 100 mu M with a correlation coefficient of 0.999. The RSD at 50 mu M NO2- was 2.6% (n=6) and the limit of detection obtained (3 sigma) was 0.20 mu M NO2-. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 12 条
[1]   Microchip-based capillary electrophoresis for immunoassays: Analysis of monoclonal antibodies and theophylline [J].
Chiem, N ;
Harrison, DJ .
ANALYTICAL CHEMISTRY, 1997, 69 (03) :373-378
[2]   CHARACTERIZATION AND REDUCTION OF INTERFERENCES IN FLOW-INJECTION ANALYSIS FOR THE IN-SITU DETERMINATION OF NITRATE AND NITRITE IN SEA-WATER [J].
DANIEL, A ;
BIROT, D ;
LEHAITRE, M ;
PONCIN, J .
ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) :413-424
[3]   DEVELOPMENT OF A MICRO FLOW-INJECTION MANIFOLD FOR THE DETERMINATION OF ORTHOPHOSPHATE [J].
DAYKIN, RNC ;
HASWELL, SJ .
ANALYTICA CHIMICA ACTA, 1995, 313 (03) :155-159
[4]  
FIEHN H, 1995, MESA MG, P289
[5]  
HARRISON DJ, 1993, ANAL CHIM ACTA, V283, P361
[6]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[7]  
HARRISON DJ, 1993, SENSOR ACTUAT B-CHEM, V10, P10724
[8]   Development and operating characteristics of micro flow injection analysis systems based on electroosmotic flow - A review [J].
Haswell, SJ .
ANALYST, 1997, 122 (01) :R1-R10
[9]   MEASUREMENT OF NITRITE AND NITRATE LEVELS IN BIOLOGICAL SAMPLES BY CAPILLARY ELECTROPHORESIS [J].
MEULEMANS, A ;
DELSENNE, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1994, 660 (02) :401-404
[10]   ELECTROOSMOTIC PUMPING AND VALVELESS CONTROL OF FLUID-FLOW WITHIN A MANIFOLD OF CAPILLARIES ON A GLASS CHIP [J].
SEILER, K ;
FAN, ZHH ;
FLURI, K ;
HARRISON, DJ .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3485-3491