The Analysis on Circulating Fluidized Bed Boiler Heat Tube Failure

被引:0
|
作者
Zhao, Bin [1 ]
Li, Junhao [1 ]
Shen, Jingquan [2 ]
Wang, Guozhong [2 ]
机构
[1] Hebei United Univ, Coll Met & Energy, Hebei Tangshan 063009, Peoples R China
[2] Zhong Neng Power Tech Dev Co Ltd, Dept Elect Plant, Beijing 100034, Peoples R China
来源
关键词
CFB; Boiler heat tubes; Failure; Statistical analysis; Technical strategy;
D O I
10.4028/www.scientific.net/AMR.291-294.1679
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Boiler heat tube failure is a long-term technical problem plaguing the production of electricity. The research on how to prevent failure of boiler heat tubes has practical significance. In this paper, select the type of the Tangshan Dong fang power plant SG-490/13.8-M572 CFB boiler as the research object, part by pressure, failure type, and run-time statistics on the heat tubes failure of two boilers throught the collation and analysis on records, the basic rules of the failure are found out, statistics show that the water wall and super heater tubes explosion causes boiler shutdown time accounted for unplanned boiler shutdown time about 82%, small power generating capacity of about 11% of the total time. Finally, relevant technical strategies including improving maintenance quality and strengthening boilers regular inspection are proposed, the unplanned outage of units is radically reduced, and the safety and reliability of boiler operation is comprehensively improved.
引用
收藏
页码:1679 / +
页数:2
相关论文
共 50 条
  • [1] FAILURE ANALYSIS OF ANCHORING SYSTEM OF A CIRCULATING FLUIDIZED BED BOILER
    Dudek, Agata
    Cugowski, Jerzy
    29TH INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS (METAL 2020), 2020, : 494 - 499
  • [2] Failures analysis of tube coating in Circulating Fluidized Bed (CFB) boiler
    Widjajanto, Teguh
    Darmadi, Djarot B.
    Irawan, Yudy S.
    Gapsari, Femiana
    HELIYON, 2024, 10 (04)
  • [3] Failure Analysis of Bed Coil Tube in an Atmospheric Fluidized Bed Combustion Boiler
    Rao, M. Venkateswara
    Pathak, S. U.
    Peshwe, D. R.
    Mahajan, Y. Y.
    Paranjape, S. A.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2014, 67 (03) : 437 - 442
  • [4] Failure Analysis of Bed Coil Tube in an Atmospheric Fluidized Bed Combustion Boiler
    M. Venkateswara Rao
    S. U. Pathak
    D. R. Peshwe
    Y. Y. Mahajan
    S. A. Paranjape
    Transactions of the Indian Institute of Metals, 2014, 67 : 437 - 442
  • [5] Failure analysis of air preheater tubes in a circulating fluidized bed boiler
    Suwarno, Suwarno
    Nugroho, Giri
    Santoso, Andik
    Witantyo
    ENGINEERING FAILURE ANALYSIS, 2021, 124
  • [6] Heat transfer in a commercial circulating fluidized bed boiler
    Cheng, Leming
    Yuhang Xuebao/Journal of Astronautics, 2000, 21 (01): : 587 - 591
  • [7] Heat transfer in a commercial circulating fluidized bed boiler
    Cheng, Leming
    Dongli Gongcheng/Power Engineering, 2000, 20 (02): : 587 - 591
  • [8] Exergy analysis of circulating fluidized bed boiler
    Liu, Yanpeng
    Zhong, Beijing
    Li, Shaohua
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 934 - 938
  • [9] Factors affecting the heat transfer in a circulating fluidized bed boiler
    Key Laboratory for Thermal Science and Power Engineering, Department of Thermal Engineering, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2007, 11 (2026-2030):
  • [10] An investigation on heat transfer to the standpipe of a circulating fluidized bed boiler
    Dutta, A