Conductive supports for combined AFM-SECM on biological membranes

被引:37
作者
Frederix, Patrick L. T. M. [1 ]
Bosshart, Patrick D. [1 ]
Akiyama, Terunobu [2 ]
Chami, Mohamed
Gullo, Maurizio R. [2 ]
Blackstock, Jason J. [3 ]
Dooleweerdt, Karin [1 ]
de Rooij, Nico F. [2 ]
Staufer, Urs [2 ]
Engel, Andreas [1 ]
机构
[1] Univ Basel, ME Muller Inst Struct Biol, Biozentrum, CH-4056 Basel, Switzerland
[2] Univ Neuchatel, Inst Microtechnol, CH-2002 Neuchatel, Switzerland
[3] Hewlett Packard Labs, Quantum Sci Res Grp, Palo Alto, CA USA
关键词
D O I
10.1088/0957-4484/19/38/384004
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Four different conductive supports are analysed regarding their suitability for combined atomic force and scanning electrochemical microscopy ( AFM-SECM) on biological membranes. Highly oriented pyrolytic graphite ( HOPG), MoS2, template stripped gold, and template stripped platinum are compared as supports for high resolution imaging of reconstituted membrane proteins or native membranes, and as electrodes for transferring electrons from or to a redox molecule. We demonstrate that high resolution topographs of the bacterial outer membrane protein F can be recorded by contact mode AFM on all four supports. Electrochemical feedback experiments with conductive cantilevers that feature nanometre-scale electrodes showed fast re-oxidation of the redox couple Ru(NH3)(6)(3+)/2(+) with the two metal supports after prolonged immersion in electrolyte. In contrast, the re-oxidation rates decayed quickly to unpractical levels with HOPG or MoS2 under physiological conditions. On HOPG we observed heterogeneity in the re-oxidation rate of the redox molecules with higher feedback currents at step edges. The latter results demonstrate the capability of conductive cantilevers with small electrodes to measure minor variations in an SECM signal and to relate them to nanometre-scale features in a simultaneously recorded AFM topography. Rapid decay of re-oxidation rate and surface heterogeneity make HOPG or MoS2 less attractive for combined AFM-SECM experiments on biological membranes than template stripped gold or platinum supports.
引用
收藏
页数:10
相关论文
共 54 条
  • [1] Development of insulated conductive probes with platinum silicide tips for atomic force microscopy in cell biology
    Akiyama, T
    Gullo, MR
    de Rooij, NF
    Tonin, A
    Hidber, HR
    Frederix, PLTM
    Engel, A
    Staufer, U
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2004, 43 (6B): : 3865 - 3867
  • [2] Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites
    Banks, CE
    Davies, TJ
    Wildgoose, GG
    Compton, RG
    [J]. CHEMICAL COMMUNICATIONS, 2005, (07) : 829 - 841
  • [3] SCANNING ELECTROCHEMICAL MICROSCOPY .12. THEORY AND EXPERIMENT OF THE FEEDBACK MODE WITH FINITE HETEROGENEOUS ELECTRON-TRANSFER KINETICS AND ARBITRARY SUBSTRATE SIZE
    BARD, AJ
    MIRKIN, MV
    UNWIN, PR
    WIPF, DO
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (04) : 1861 - 1868
  • [4] SCANNING ELECTROCHEMICAL MICROSCOPY - INTRODUCTION AND PRINCIPLES
    BARD, AJ
    FAN, FRF
    KWAK, J
    LEV, O
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (02) : 132 - 138
  • [5] ATOMIC FORCE MICROSCOPE
    BINNIG, G
    QUATE, CF
    GERBER, C
    [J]. PHYSICAL REVIEW LETTERS, 1986, 56 (09) : 930 - 933
  • [6] Ultra-flat platinum surfaces from template-stripping of sputter deposited films
    Blackstock, JJ
    Li, ZY
    Freeman, MR
    Stewart, DR
    [J]. SURFACE SCIENCE, 2003, 546 (2-3) : 87 - 96
  • [7] Nanowire probes for high resolution combined scanning electrochemical Microscopy - Atomic force Microscopy
    Burt, DP
    Wilson, NR
    Weaver, JMR
    Dobson, PS
    Macpherson, JV
    [J]. NANO LETTERS, 2005, 5 (04) : 639 - 643
  • [8] CLEMMER CR, 1992, SCANNING MICROSCOPY, V6, P319
  • [9] CRYSTAL-STRUCTURES EXPLAIN FUNCTIONAL-PROPERTIES OF 2 ESCHERICHIA-COLI PORINS
    COWAN, SW
    SCHIRMER, T
    RUMMEL, G
    STEIERT, M
    GHOSH, R
    PAUPTIT, RA
    JANSONIUS, JN
    ROSENBUSCH, JP
    [J]. NATURE, 1992, 358 (6389) : 727 - 733
  • [10] In situ investigation of localized corrosion of aluminum alloys in chloride solution using integrated EC-AFM/SECM techniques
    Davoodi, A
    Pan, J
    Leygraf, C
    Norgren, S
    [J]. ELECTROCHEMICAL AND SOLID STATE LETTERS, 2005, 8 (06) : B21 - B24