First successful implantation of a biodegradable metal stent into the left pulmonary artery of a preterm baby

被引:336
作者
Zartner, P
Cesnjevar, R
Singer, H
Weyand, M
机构
[1] Deutsch Kinderherzzentrum Sankt Augustin, D-53757 St Augustin, Germany
[2] Univ Erlangen Nurnberg, Dept Cardiothorac Surg, Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Pediat & Adolescent Med, Div Pediat Cardiol, Erlangen, Germany
关键词
corrosion; congenital heart disease; magnesium; arterial stenosis; pulmonary stenosis;
D O I
10.1002/ccd.20520
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Stent implantation in the youngest patients with a congenital heart disease implicates limitations concerning further vessel growth, the need of staged redilation, and later surgical removal. The search to overcome these restrictions led to open stent designs, with a wide adaptability to the vessel growth and recently to the development of bioabsorbable stent materials. A preterm baby born at 26 weeks of gestation was referred to our clinic following inadvertent ligation of the left pulmonary artery. Despite efficient debanding, the left lung perfusion was absent. Implantation of a biodegradable 3 mm magnesium stent was performed in a hybrid procedure when the baby weighed 1.7 kg. Reperfusion of the left lung was established and persisted throughout the 4-month follow-up period during which the gradual degradation process of the stent completed. Additional interventions, should they become necessary, seem not to be limited. Despite the small size of the baby, the degradation process was clinically well tolerated. The mechanical and degradation characteristics of the magnesium stent proved to be adequate to secure reperfusion of the previously occluded left pulmonary artery. Bioabsorbable stents with different diameters may help develop new strategies in the therapy of vessel stenosis in pediatric patients. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:590 / 594
页数:5
相关论文
共 16 条
[11]   Preliminary results after application of absorbable metal stents in patients with critical limb ischemia [J].
Peeters, P ;
Bosiers, M ;
Verbist, J ;
Deloose, K ;
Heublein, B .
JOURNAL OF ENDOVASCULAR THERAPY, 2005, 12 (01) :1-5
[12]  
Ravn HB, 1999, MAGNESIUM RES, V12, P191
[13]   Stent implantation of the arterial duct in newborns with duct-dependent circulation [J].
Schneider, M ;
Zartner, P ;
Sidiropoulos, A ;
Konertz, W ;
Hausdorf, G .
EUROPEAN HEART JOURNAL, 1998, 19 (09) :1401-1409
[14]   First human use of a new PFM "Babystent" [J].
Schneider, MBE ;
Fischer, G ;
Lange, PE .
HEART, 2003, 89 (01) :83-83
[15]   Various reasons for repeat dilatation of stented pulmonary arteries in paediatric patients [J].
Schneider, MBE ;
Zartner, P ;
Duveneck, K ;
Lange, PE .
HEART, 2002, 88 (05) :505-509
[16]   Serum levels of magnesium at birth related to complications of immaturity [J].
Stigson, L ;
Kjellmer, I .
ACTA PAEDIATRICA, 1997, 86 (09) :991-994