PATIENT DOSES IN COMPUTED TOMOGRAPHY EXAMINATIONS IN TWO REGIONS OF THE RUSSIAN FEDERATION

被引:6
作者
Chipiga, L. [1 ,2 ]
Bernhardsson, C. [3 ]
机构
[1] Res Inst Radiat Hyg, Mira Str 8, St Petersburg 197101, Russia
[2] Fed Almazov North West Med Res Ctr, Akkuratova Str 2, St Petersburg 197341, Russia
[3] Lund Univ, Skane Univ Hosp Malmo, Med Radiat Phys, Dept Translat Med, Inga Marie Nilssons Gata 49, S-20502 Malmo, Sweden
关键词
CT;
D O I
10.1093/rpd/ncv516
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Computed tomography (CT) is often a justified diagnostic tool, but is also associated with high exposure of the patients. Due to the rapid increase in the number of CT units and thus the availability of CT examinations in Russia, there is a growing need for optimisation within this field. In order to develop proper optimisation procedures for CT, the two regions St. Petersburg and Belgorod of Russia were chosen, representing an urban and a rural region, respectively. In 2014, a survey was conducted of the parameters applied in CT examinations in these regions, and the results show that the highest effective doses were observed for investigations of abdomen, reaching up to 137 mSv, and pelvic CT examinations, reaching up to 58 mSv, both with contrast agents. The dose distributions were approximately log-normal, and for the majority of the examinations, the 75th percentiles of the CT dose distributions in the Belgorod region were higher than observed in St. Petersburg. The aim of the current project is primarily to define and implement diagnostic reference levels as a part of the process of optimisation of CT examinations in Russia.
引用
收藏
页码:240 / 244
页数:5
相关论文
共 10 条
  • [1] Aldrich JE, 2006, CAN ASSOC RADIOL J, V57, P79
  • [2] RUSSIAN PRACTICAL GUIDANCE ON RADIOLOGICAL SUPPORT FOR JUSTIFICATION OF X-RAY AND NUCLEAR MEDICINE EXAMINATIONS
    Balonov, M.
    Golikov, V.
    Kalnitsky, S.
    Zvonova, I.
    Chipiga, L.
    Sarycheva, S.
    Shatskiy, I.
    Vodovatov, A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 39 - 42
  • [3] Balonov M., 2014, ASSESSMENT RAD RISKS, V45
  • [4] European Commission, 2013, DOS DAT 2 DDM2 DRAFT
  • [5] International Commission on Radiation Protection, 2007, ANN ICRP, V37
  • [6] Repin V.S., 2014, INFORM B DOSES POPUL
  • [7] CT-Expo - a novel program for dose evaluation in CT
    Stamm, G
    Nagel, HD
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (12): : 1570 - 1576
  • [8] Swedish Radiation Protection Authority, 2002, REG GEN ADV DIAGN ST
  • [9] PATIENT DOSES IN CT EXAMINATIONS IN SWITZERLAND: IMPLEMENTATION OF NATIONAL DIAGNOSTIC REFERENCE LEVELS
    Treier, R.
    Aroua, A.
    Verdun, F. R.
    Samara, E.
    Stuessi, A.
    Trueb, Ph. R.
    [J]. RADIATION PROTECTION DOSIMETRY, 2010, 142 (2-4) : 244 - 254
  • [10] van der Molen AJ, 2013, INSIGHTS IMAGING, V4, P383, DOI 10.1007/s13244-013-0253-9