Tomographic reconstruction of the retina using a confocal scanning laser ophthalmoscope

被引:15
|
作者
Vieira, P [1 ]
Manivannan, A
Lim, CS
Sharp, P
Forrester, JV
机构
[1] Univ Aberdeen, Dept Biomed Phys & Bioengn, Aberdeen AB25 2ZD, Scotland
[2] Univ Aberdeen, Dept Ophthalmol, Aberdeen AB25 2ZD, Scotland
基金
英国惠康基金;
关键词
confocal; scanning laser ophthalmoscope; reconstruction; tomographic imaging;
D O I
10.1088/0967-3334/20/1/001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Retinal imaging with a confocal scanning laser ophthalmoscope (cSLO) involves scanning a small laser beam over the retina and constructing an image from the reflected light. By applying the confocal principle, tomographic images can be produced. However, the thickness of such slices, when compared with the retinal thickness, is too large to give useful 3D retinal images. In this study an algorithm has been developed which fits a double Gaussian curve to the axial intensity profiles generated from a stack of image slices. The underlying assumption is that the laser light has mainly been reflected by two structures in the retina, the internal limiting membrane and the retinal pigment epithelium. From the fitted curve, topographic images and novel thickness images of the retina can be generated. The technique has been applied to three normal volunteers and seven patients with macular pathology (cystoid macular oedema and macular hole) demonstrating the clinical value of the technique. The improvement in accuracy achieved by using a double rather than a single Gaussian is also demonstrated.
引用
收藏
页码:1 / 19
页数:19
相关论文
共 50 条
  • [41] Comparison of fundus autofluorescence images acquired by the confocal scanning laser ophthalmoscope (488 nm excitation) and the modified Topcon fundus camera (580 nm excitation)
    A. Deli
    L. Moetteli
    A. Ambresin
    I. Mantel
    International Ophthalmology, 2013, 33 : 635 - 643
  • [42] QUANTITATIVE ANALYSIS OF CYSTOID MACULAR EDEMA USING SCANNING LASER OPHTHALMOSCOPE IN MODIFIED DARK-FIELD IMAGING
    Katome, Takashi
    Mitamura, Yoshinori
    Nagasawa, Toshihiko
    Eguchi, Hiroshi
    Naito, Takeshi
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (09): : 1892 - 1899
  • [43] Second harmonic generation imaging of the pig lamina cribrosa using a scanning laser ophthalmoscope-based microscope
    M. Agopov
    L. Lomb
    O. La Schiazza
    J. F. Bille
    Lasers in Medical Science, 2009, 24 : 787 - 792
  • [44] Hemodynamic changes in two patients with retinal circulatory disturbances shown by fluorescein angiography using a scanning laser ophthalmoscope
    Masaoka, N
    Nakaya, K
    Koura, Y
    Ohsaki, M
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (02): : 155 - 160
  • [45] The effect of blood vessels on the computation of the scanning laser ophthalmoscope retinal thickness map
    Mantri, A.
    Li, Y.
    Hutchings, N.
    Flanagan, J.
    Holmes, T.
    MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514
  • [46] Vitreous videography using the scanning laser ophthalmoscope (Reprinted with permission from American Medical Association, copyright 1995)
    Kakehashi, A
    Ishiko, S
    Konno, S
    Akiba, J
    Kado, M
    Yoshida, A
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 1995, 39 (04) : 377 - 383
  • [47] Second harmonic generation imaging of the pig lamina cribrosa using a scanning laser ophthalmoscope-based microscope
    Agopov, M.
    Lomb, L.
    La Schiazza, O.
    Bille, J. F.
    LASERS IN MEDICAL SCIENCE, 2009, 24 (05) : 787 - 792
  • [48] Fundus imaging in newborn children with wide-field scanning laser ophthalmoscope
    Magnusdottir, Vigdis
    Vehmeijer, Wouter B.
    Eliasdottir, Thorunn S.
    Hardarson, Sveinn H.
    Schalij-Delfos, Nicoline E.
    Stefansson, Einar
    ACTA OPHTHALMOLOGICA, 2017, 95 (08) : 842 - 844
  • [49] Scanning laser ophthalmoscope multifocal electroretinography and microperimetry in patients with Stargardt's disease
    Rudolph, G
    Kalpadakis, P
    Ehrt, O
    Berninger, T
    Kampik, A
    OPHTHALMOLOGE, 2003, 100 (09): : 720 - 726
  • [50] Multifocal electroretinogram. Comparison between scanning laser ophthalmoscope and monitor stimulation
    Poloschek, CM
    Friede, T
    Krastel, H
    Holz, FG